Wei Wang

Prof. Wei Wang

School of Electrical Engineering, Southeast University, Nanjing 210096, China
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XWXueqing Wang
Xueqing Wang
ZWZheng Wang
Zheng Wang
ZXZhixian Xu
Zhixian Xu
Ming ChengMing Cheng
Ming Cheng
Wei WangWei Wang
Wei Wang
Yihua HuYihua Hu
Yihua Hu
In this paper, fault diagnosis and tolerant control strategies have been studied comprehensively for dual-three phase PMSM drives to improve the reliability. Based on direct torque control (DTC) with space vector modulation (SVM), a series of diagnostic and tolerant control methods have been proposed for five types of faults, namely speed-sensor fault, DC-link voltage-sensor fault, current-sensor fault, open-phase fault and open-switch fault. Firstly, diagnosis and tolerant schemes are proposed for speed-sensor fault by estimating the rotor angle speed with the rotating speed of stator flux. Secondly, diagnosis and tolerant schemes are proposed for DC-link voltage-sensor fault by combining the current model based stator flux observer with the voltage model based stator flux observer. Thirdly, a three-step method is designed to diagnose three types of faults related to current signals, namely current-sensor fault, open-phase fault and open-switch fault simultaneously. A vector space decomposition (VSD) based current estimation method is proposed to achieve fault-tolerant control for the current-sensor fault, and the voltage compensation based fault-tolerant control is presented for both open-phase fault and open-switch fault. The experiments have been taken on a laboratory prototype to verify the effectiveness of the proposed fault diagnosis and tolerance schemes.

27 April 2016 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Wei WangWei Wang
Wei Wang
JZJinghao Zhang
Jinghao Zhang
MCMing Cheng
Ming Cheng
SLShihua Li
Shihua Li
In this paper, a fault-tolerant control is proposed for dual three-phase permanent-magnet synchronous machine (PMSM) drives under open-phase faults. The object of the proposed fault-tolerant control is to maximize the torque capacity while the overcurrent protection is taken into account. Hence, the proposed fault-tolerant control is named as torque mode in this paper. Another existed fault-tolerant control for dual three-phase PMSM drives under open-phase faults is loss mode, in which the system copper loss is minimized. Torque mode is compared with loss mode, and two important conclusions are given: 1) loss mode can reduce more copper loss; and 2) torque mode can output more torque. The performances of torque mode and loss mode are verified by experimental results.

5 June 2013 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Wei WangWei Wang
Wei Wang
MCMing Cheng
Ming Cheng
BZBangfu Zhang
Bangfu Zhang
YZYing Zhu
Ying Zhu
SDShichuan Ding
Shichuan Ding
A fault-tolerant permanent-magnet traction module is proposed for subway application, which has three different operation modes: normal, isolation, and fault-tolerant mode. In normal mode, 2 three-phase permanent-magnet synchronous machines (PMSMs) are controlled by 2 three-leg voltage-source inverters (VSIs), respectively. The proposed module can output maximum torque and reach the maximum velocity. When one leg fails, the corresponding PMSM is isolated from the fault VSI and the fault subway train operates in isolation mode, in which the traction effort is reduced but the maximum velocity can be maintained under light load. However, the fault subway train will stop if the load is heavy. To avoid the stop, the fault subway train is switched into fault-tolerant mode, in which the healthy VSI and fault VSI are reconfigured to 1 five-leg VSI by a fault-tolerant bridge. Due to lower phase-phase voltage apportionment ratio, the fault-tolerant mode is not used until the velocity is decreased to half of the maximum velocity. In fault-tolerant mode, the nonadjacent selection principle is proposed to prevent the common leg from overcurrent damage. The subway train equipped with the proposed module can maintain basic operation performances if any leg fails. The performances are analyzed and the effectiveness is verified by experimental results.

26 October 2016 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Wei WangWei Wang
Wei Wang
JZJinghao Zhang
Jinghao Zhang
MCMing Cheng
Ming Cheng
In addition to field-oriented control and direct torque control, the model predictive control (MPC) is another typical control method for permanent-magnet synchronous machine (PMSM) drives. In some critical applications, fault-tolerant controls are usually required. The faults of PMSM drives in this paper are limited as a single-phase open-circuit fault, which may be caused by open circuit or short circuit of one power switch. In the postfault operation, the neutral point of the PMSM is connected to a redundant leg. As is known, MPC is a model-based control method. Since the PMSM has different mathematical models in both normal and postfault operations, two different MPCs (MPC-I and MPC-II) should be, respectively, designed for both normal and postfault operations according to traditional thinking. However, it is first found in this paper that the faulty PMSM drive can be treated as an equivalent healthy PMSM drive, and MPC-I can be shared by both normal and postfault operations without any modification. The major contribution of this paper is to find this fact, and verify it with theoretical analysis and experimental validation. Obviously, this finding will simplify the whole control method of PMSM drives considering single-phase open-circuit fault.

27 March 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
XWXueqing Wang
Xueqing Wang
ZWZheng Wang
Zheng Wang
ZXZhixian Xu
Zhixian Xu
Wei WangWei Wang
Wei Wang
Bo WangBo Wang
Bo Wang
JCJun Chen
Jun Chen
In this paper, a deadbeat predictive current control based fault-tolerant scheme is proposed and developed for dual three-phase PMSM drives. For open-phase fault of dualthree phase PMSM, the current references are derived without low-order components for minimum stator copper loss. The utilization of deadbeat predictive current control guarantees high control bandwidth for the current references under faulttolerant operation. Then, a fault-tolerant control scheme is proposed for open-switch fault based on hybrid current references, which can fully utilize the remaining one health switch in the faulty inverter leg and minimize the stator copper loss. The additional copper loss caused by the open-switch fault can be reduced by around half with the proposed fault-tolerant control compared to previous remedial strategies. Thus, the ultimate torque output under open-switch fault can be increased by around 20%. The machine model, the space vector diagram, and the control structure of motor systems remain unchanged with the proposed fault-tolerant control scheme. The validity of the proposed fault-tolerant control schemes is verified by experiments.

26 February 2016 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Wei WangWei Wang
Wei Wang
JZJinghao Zhang
Jinghao Zhang
MCMing Cheng
Ming Cheng
A dual-level hysteresis current control (DHCC) is proposed for the five-leg drive system, in which two same three-phase permanent-magnet synchronous machines (PMSMs) are controlled by one five-leg voltage-source inverter. To overcome the coupling of the two PMSMs, the master–slave selection principle is introduced. The coupling phase with the larger absolute value of the phase current error is determined as the master coupling phase and the leg-switch-state of the common leg is set as the phase-switch-state of the master coupling phase. On the other hand, the phase-switch-states of four individual phases are directly assigned to the four individual legs, respectively. The executing process of DHCC does not require any machine parameters, which enhances the system robustness. The effectiveness of DHCC is verified by experimental results.