Young-Bong Choi

Dr. Young-Bong Choi

Dankook University, South Korea
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2021 in Membranes
Verified
Journal Article
Open access
PDF file
WJWon-Yong Jeon
Won-Yong Jeon
HKHyug-Han Kim
Hyug-Han Kim
Young-Bong ChoiYoung-Bong Choi
Young-Bong Choi
The electrochemical-based detection of glucose is widely used for diagnostic purposes and is mediated by enzyme-mediated signal transduction mechanisms. For such applications, recent attention has focused on utilizing the oxygen-insensitive glucose dehydrogenase (GDH) enzyme in place of the glucose oxidase (GOx) enzyme, which is sensitive to oxygen levels. Currently used Ru-based redox mediators mainly work with GOx, while Ru(dmo–bpy)2Cl2 has been proposed as a promising mediator that works with GDH. However, there remains an outstanding need to improve Ru(dmo–bpy)2Cl2 attachment to electrode surfaces. Herein, we report the use of polydopamine-functionalized multi-walled carbon nanotubes (PDA-MWCNTs) to effectively attach Ru(dmo–bpy)2Cl2 and GDH onto screen-printed carbon electrodes (SPCEs) without requiring a cross–linker. PDA-MWCNTs were characterized by Fourier transform infrared (FT–IR) spectroscopy, Raman spectroscopy, and thermal gravimetric analysis (TGA), while the fabrication and optimization of Ru(dmo–bpy)2Cl2/PDA-MWCNT/SPCEs were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements. The experimental results demonstrate a wide linear range of glucose-concentration-dependent responses and the multi-potential step (MPS) technique facilitated the selective detection of glucose in the presence of physiologically relevant interfering species, as well as in biological fluids (e.g., serum). The ease of device fabrication and high detection performance demonstrate a viable pathway to develop glucose sensors based on the GDH enzyme and Ru(dmo–bpy)2Cl2 redox mediator and the sensing strategy is potentially extendable to other bioanalytes as well.

10 December 2015 in Sensors
Verified
Journal Article
Open access
PDF file
WJWon-Yong Jeon
Won-Yong Jeon
Young-Bong ChoiYoung-Bong Choi
Young-Bong Choi
HKHyug-Han Kim
Hyug-Han Kim
Disposable screen-printed nickel/carbon composites on indium tin oxide (ITO) electrodes (DSPNCE) were developed for the detection of glucose without enzymes. The DSPNCE were prepared by screen-printing the ITO substrate with a 50 wt% nickel/carbon composite, followed by curing at 400 °C for 30 min. The redox couple of Ni(OH)2/NiOOH was deposited on the surface of the electrodes via cyclic voltammetry (CV), scanning from 0–1.5 V for 30 cycles in 0.1 M NaOH solution. The DSPNCE were characterized by field-emission scanning electron microscopy (FE-SEM), X-ray photoelectron spectroscopy (XPS), and electrochemical methods. The resulting electrical currents, measured by CV and chronoamperometry at 0.65 V vs. Ag/AgCl, showed a good linear response with glucose concentrations from 1.0–10 mM. Also, the prepared electrodes showed no interference from common physiologic interferents such as uric acid (UA) or ascorbic acid (AA). Therefore, this approach allowed the development of a simple, disposable glucose biosensor.

13 October 2014 in Sensors
Verified
Journal Article
Open access
PDF file
Young-Bong ChoiYoung-Bong Choi
Young-Bong Choi
NKNam-Hyuk Kim
Nam-Hyuk Kim
SKSeung-Hoi Kim
Seung-Hoi Kim
GTGun-Sik Tae
Gun-Sik Tae
HKHyug-Han Kim
Hyug-Han Kim
By directly coordinating hippuric acid (HA) to the ferrate (Fe) as an electron transfer mediator, we synthesized a Fe-HA complex, which shows a good electrochemical signal and thus enables the electrochemical immunoanalysis for HA. We electrodeposited organic films containing imidazole groups on the electrode surface and then bonded Ni ion (positive charge) to induce immobilization of Fe-HA (negative charge) through the electrostatic interaction. The heterogeneous competitive immunoassay system relies on the interaction between immobilized Fe-HA antigen conjugate and free HA antigen to its antibody (anti-HA). The electric signal becomes weaker due to the hindered electron transfer reaction when a large-sized HA antibody is bound onto the Fe-HA. However, in the presence of HA, the electric signal increases because free HA competitively reacts with the HA antibody prior to actual reaction and thus prevents the HA antibody from interacting with Fe-HA at the electrode surface. This competition reaction enabled an electrochemical quantitative analysis of HA concentration with a detection limit of 0.5 μg mL−1, and thus allowed us to develop a simple and rapid electrochemical immunosensor.

14 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
KAKung Ahn
Kung Ahn
SHSangjin Han
Sangjin Han
KYKyeongeui Yun
Kyeongeui Yun
WLWooseok Lee
Wooseok Lee
DLDong-Geol Lee
Dong-Geol Lee
YAYong Ju Ahn
Yong Ju Ahn
The human skin sebum suggests that it (along with other epidermal surface lipids) plays a role in skin barrier formation, the moderation of cutaneous inflammation, and antimicrobial defense. Various methods have been developed for collecting and measuring skin sebum. We tested methods of detection using “color intensity”, by staining the skin casual sebum. This process was conducted in three steps; first, the selection of materials for sebum collection; second, staining the collected sebum; third, the development of a device that can measure the level of stained sebum. A plastic film was used to effectively collect sebum that increased with the replacement time of the sebum. In addition, the collected sebum was stained with Oil Red O (ORO) and checked with RGB; as a result, the R2 value was higher than 0.9. It was also confirmed that the correlation value was higher than 0.9 in the comparison result with Sebumeter®, which is a common standard technology. Finally, it was confirmed that the R2 value was higher than 0.9 in the detection value using the sensor. In conclusion, we have proven the proof of concept (PoC) for this method, and we would like to introduce an effective sebum measurement method that differs from the existing method.

24 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
WJWon-Yong Jeon
Won-Yong Jeon
CLChang-Jun Lee
Chang-Jun Lee
Tun Naw SutTun Naw Sut
Tun Naw Sut
HKHyug-Han Kim
Hyug-Han Kim
Young-Bong ChoiYoung-Bong Choi
Young-Bong Choi
The electrochemical-based detection of uric acid (UA) is widely used for diagnostic purposes. However, various interfering species such as ascorbic acid, dopamine, and glucose can affect electrochemical signals, and hence there is an outstanding need to develop improved sensing platforms to detect UA with high selectivity. Herein, we report a pentagonal mediator-based non-enzymatic electrochemical biosensing platform to selectively measure UA in the presence of interfering species. The working electrode was fabricated by electrodepositing polymerized 1-vinylimidazole (PVI), which has an imidazole ligand, onto indium tin oxide (ITO), and then conjugating nickel ions to the PVI-coated ITO electrode. Electrode performance was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements and integrated together with pentacyanoammineferrate, which can bind to the amine groups of UA and function as an electron transferring mediator. The experimental results showed a wide linear range of UA concentration-dependent responses and the multi-potential step (MPS) technique facilitated selective detection of UA in the presence of physiologically relevant interfering species. Altogether, these findings support that pentacyanoammineferrate-based non-enzymatic electrodes are suitable biosensing platforms for the selective measurement of UA, and such approaches could potentially be extended to other bioanalytes as well.

29 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Young-Bong ChoiYoung-Bong Choi
Young-Bong Choi
WJWon-Yong Jeon
Won-Yong Jeon
HKHyug-Han Kim
Hyug-Han Kim
In this study, a homogeneous method featuring simple, one-step detection was developed to analyze hippuric acid (HA), a major metabolite of toluene. High sensitivity was achieved with the facile immobilization of poly(vinylimidazole) (PVI) on an indium tin oxide (ITO) electrode. Using a previously developed approach, pentacyanoferrate was coordinated with pyridyl-N ligands, and the redox-active Fe(II/III) centers were bound to Ni(II) ions on the electrode via electrostatic cyanide bridges. The detection was accomplished by the competitive binding of free HA and pentacyanoferrate-(4-aminomethylpyridine-hippuric acid) (Fe-HA, the electron transfer mediator) to the HA antibody on the Ni(II) ions-modified PVI-ITO (Ni-PVI-ITO) electrode. The electrical and physicochemical characterization of the electrode was carried out by cyclic voltammetry, differential pulse voltammetry, field emission scanning electron microscopy, and X-ray photoelectron spectroscopy. At low mediator concentrations, the electrical signals were proportional to the HA concentration between 0.1 µg/mL and 1.0 mg/mL. The same method may be extended to other small organic molecules.