The electrochemical-based detection of glucose is widely used for diagnostic purposes and is mediated by enzyme-mediated signal transduction mechanisms. For such applications, recent attention has focused on utilizing the oxygen-insensitive glucose dehydrogenase (GDH) enzyme in place of the glucose oxidase (GOx) enzyme, which is sensitive to oxygen levels. Currently used Ru-based redox mediators mainly work with GOx, while Ru(dmo–bpy)2Cl2 has been proposed as a promising mediator that works with GDH. However, there remains an outstanding need to improve Ru(dmo–bpy)2Cl2 attachment to electrode surfaces. Herein, we report the use of polydopamine-functionalized multi-walled carbon nanotubes (PDA-MWCNTs) to effectively attach Ru(dmo–bpy)2Cl2 and GDH onto screen-printed carbon electrodes (SPCEs) without requiring a cross–linker. PDA-MWCNTs were characterized by Fourier transform infrared (FT–IR) spectroscopy, Raman spectroscopy, and thermal gravimetric analysis (TGA), while the fabrication and optimization of Ru(dmo–bpy)2Cl2/PDA-MWCNT/SPCEs were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements. The experimental results demonstrate a wide linear range of glucose-concentration-dependent responses and the multi-potential step (MPS) technique facilitated the selective detection of glucose in the presence of physiologically relevant interfering species, as well as in biological fluids (e.g., serum). The ease of device fabrication and high detection performance demonstrate a viable pathway to develop glucose sensors based on the GDH enzyme and Ru(dmo–bpy)2Cl2 redox mediator and the sensing strategy is potentially extendable to other bioanalytes as well.
A glucose-reactive enzyme-based biofuel cell system (EBFC) was recently introduced in the scientific community for biomedical applications, such as implantable artificial organs and biosensors for drug delivery. Upon direct contact with tissues or organs, an implanted EBFC can exert effects that damage or stimulate intact tissue due to its byproducts or generated electrical cues, which have not been investigated in detail. Here, we perform a fundamental cell culture study using a glucose dehydrogenase (GDH) as an anode enzyme and bilirubin oxidase (BOD) as a cathode enzyme. The fabricated EBFC had power densities of 15.26 to 38.33 nW/cm2 depending on the enzyme concentration in media supplemented with 25 mM glucose. Despite the low power density, the GDH-based EBFC showed increases in cell viability (~150%) and cell migration (~90%) with a relatively low inflammatory response. However, glucose oxidase (GOD), which has been used as an EBFC anode enzyme, revealed extreme cytotoxicity (~10%) due to the lethal concentration of H2O2 byproducts (~1500 µM). Therefore, with its cytocompatibility and cell-stimulating effects, the GDH-based EBFC is considered a promising implantable tool for generating electricity for biomedical applications. Finally, the GDH-based EBFC can be used for introducing electricity during cell culture and the fabrication of organs on a chip and a power source for implantable devices such as biosensors, biopatches, and artificial organs.
Disposable screen-printed nickel/carbon composites on indium tin oxide (ITO) electrodes (DSPNCE) were developed for the detection of glucose without enzymes. The DSPNCE were prepared by screen-printing the ITO substrate with a 50 wt% nickel/carbon composite, followed by curing at 400 °C for 30 min. The redox couple of Ni(OH)2/NiOOH was deposited on the surface of the electrodes via cyclic voltammetry (CV), scanning from 0–1.5 V for 30 cycles in 0.1 M NaOH solution. The DSPNCE were characterized by field-emission scanning electron microscopy (FE-SEM), X-ray photoelectron spectroscopy (XPS), and electrochemical methods. The resulting electrical currents, measured by CV and chronoamperometry at 0.65 V vs. Ag/AgCl, showed a good linear response with glucose concentrations from 1.0–10 mM. Also, the prepared electrodes showed no interference from common physiologic interferents such as uric acid (UA) or ascorbic acid (AA). Therefore, this approach allowed the development of a simple, disposable glucose biosensor.
Urinary hippuric acid (HA), of molecular weight 180 Da, is one of the major metabolites in toluene-exposed humans and is a major biological indicator. Simple and ubiquitous monitoring of exposure to toluene is very important in occupational health care, and a microfluidic chip-based electrochemical immunoassay for rapid and quantitative detection of HA in human urine is proposed in this paper. The system employs a conjugate of ferrocene (Fc) and hippuric acid (HA). The competition between hippuric acid (HA) and the ferrocene-hippuric acid complex (Fc-Lys-HA) to bind with a HA antibody coated onto polybeads generated electrical signals proportional to the HA concentration in the range of 0–40 mg mL−1. All the complicated HA detection processes were integrated on the single microfluidic platform. The quantitative advantages of our HA detection chip are as follows: (1) the total chip size was reduced to 3.0 × 2.0 × 0.5 cm and is small enough to be portable, (2) the assay time took 1 min, and is shorter than that of conventional electrochemical HA immunoassay systems (about 20 min) and (3) 40 μL of the sample solution was enough to detect HA in the range of 0–40 mg mL−1, which is enough range to be used for the point-of-care system. In addition, we suggest the improved chip-based HA assay method by the combination of electrochemical and enzymatic amplification processes for the detection of greater electrical signals. The sensitivity of the combined method was increased about three times compared to that of the non-enzymatic process.
Applying a nanocomposite to increase the conductivity of an electrode can facilitate electrochemical analysis. In this regard, multi-walled carbon nanotubes (MWCNTs) evenly dispersed in hydrophilic solution can play an important role in electrochemical bio-sensing due to their unique properties, such as their high electrical conductivity and ability to conjugate with hydrophilic enzymes. Herein, we report the simple ultrasonic synthesis of a highly dispersible, enzyme-binding nanocomposite, poly(acrylamide)-co-poly(vinyl imidazole) (7:1 mol ratio)-MWCNTs (PAA-PVI@MWCNTs). This material, having a zeta potential of 36.6 ± 0.53 mV, was applied as a film to an electrode surface and stably bound with glucose oxidase to transfer an electron between the enzyme and electrode in the presence of glucose. The PAA-PVI@MWCNTs composite, which was readily dispersed in deionized water, can be used as a biocompatible material for applications such as bio-sensing, point-of-care testing (POCT), and other health care functions.