Oxygen deficiency and coldness are the main challenges for highway tunnel construction in high-altitude areas such as western Sichuan plateau. The artificial oxygen supply and anti-freezing structure in the tunnel construction process has a significant impact on vocational health and the environment. Thus, the conditions of tunnels need to be carefully evaluated before construction. However, the current design code for tunnel construction contains few instructions about these aspects. This paper attempts to establish a simple evaluation method to guide the construction design by analyzing the oxygen partial pressure of trachea, the mean temperature of the coldest month, and the maximum freezing depth for tunnel projects in western Sichuan plateau. Based on the on-site meteorological monitoring at different altitudes of three typical tunnels in the western Sichuan plateau and the comparative analysis of the existing meteorological data, the corresponding relationships between the three parameters and the altitude were investigated. The thresholds by altitude for grading the tunnels are identified as 2100 m and 4200 m, respectively. The highway tunnels in the western Sichuan plateau are graded in three categories, namely, general-altitude tunnels, high-altitude tunnels, and ultra-high-altitude tunnels. The corresponding measures of oxygen supply and freezing prevention for different graded tunnels are recommended. The results would provide a basis for the design and construction of new tunnels and enhance the service life and operations safety of the tunnels in western Sichuan plateau and other similar high-altitude areas.
When a tunnel orthogonally traverses a large bedrock landslide, the interaction between the tunnel and the bedrock can easily disturb the stability of the slope and deformation of tunnel structures. In this work, Jimei tunnel in southwest China was studied as an example. The physical parameters of the landslide were inverted based on uniform design and a radial basis function neural network model and a model was established for the interaction of tunnel and bedrock landslide. Simulations showed that tunnel construction resulted in tensile failure at the trailing edge of bedrock landslide and clear deformation in the left line of the tunnel. This was consistent with the field damage observed in this work. A comparative analysis was performed of structural stability after the application of three schemes of earth-rock clearing, load-reducing, and slide-resistant pile arrangements. Optimal measures for landslide reinforcement were determined to ensure smooth tunnel construction and reduce project cost. Two years of continuous post-construction monitoring indicated that the stability of tunnel and landslide was preserved and treatment goal was achieved. Calculation methods and control measures developed in the current research for tunnels orthogonally traversing bedrock landslides provided a useful reference for similar projects in the future.
The freeze–thaw effect has a significant impact on the strength deterioration of tunnel-lining concrete in cold regions. Therefore, the strength deterioration characteristics of concrete in a tunnel were studied, and silicone coating materials were used to improve its frost resistance and durability under freeze–thaw cycles. Freeze–thaw cycle tests were conducted on concrete specimens with different coatings. The freeze–thaw damage phenomenon, dynamic elastic modulus, and mass loss of the specimens were used to evaluate the freeze–thaw durability of concrete strengthened with coatings. The results demonstrated that silicone coatings effectively prevented moisture and corrosive substances from infiltrating the concrete, thereby enhancing its durability; the silicone–polyether hybrid had the most significant frost resistance at 500 g/m2 and silane type III at 300 g/m2, with freezing resistance times of 175 and 300, respectively. During the freeze–thaw process, the strength reduction rate of specimens was much greater than the mass loss rate of concrete. Taking into account the water environment surrounding the lining concrete and the site temperature, an equivalent indoor freeze–thaw cycle conversion model was established. The results can provide an experimental basis for selecting better frost-resistant materials for tunnel concrete in cold regions.
In contiguous seam mining, the sudden large-scale collapse of a hard roof in an overlying goaf generates violent impact airflow, driving hazardous gases into the underlying working face and seriously threatening production safety. However, quantitative analysis of airflow responses under such transient impacts is rare for conventional exhaust ventilation systems, and proactive control strategies remain lacking. This study hypothesized that replacing exhaust ventilation with a forced ventilation system builds a sufficient counter-pressure gradient across the working face to block the downward migration of hazardous gases. Taking the Longhua Coal Mine as the engineering background, this study combines a theoretical velocity model of roof-collapse-induced impact airflow with numerical simulations and subsequently implements a forced ventilation system on site. Results show that under exhaust ventilation, roof collapse greatly intensifies air leakage in the goaf, causing the CO concentration at the return corner to spike to 5000 ppm within only 0.2 s. In contrast, the field-deployed forced ventilation system effectively suppresses this impact: by keeping the pressure difference across the air regulator within 338–417 Pa, the CO concentration drops from 36 ppm to below 15 ppm. Complemented by a real-time monitoring system for goaf pressure surges and hazardous gases, this strategy successfully shifts disaster control from passive ventilation to active aerodynamic suppression. This study provides a robust theoretical foundation and practical engineering reference for disaster prevention in contiguous seam mining.