Objective: Recent advances in development of low-cost single-channel electroencephalography (EEG) headbands have opened new possibilities for applications in health monitoring and brain-computer interface (BCI) systems. These recorded EEG signals, however, are often contaminated by eye blink artifacts that can yield the fallacious interpretation of the brain activity. This paper proposes an efficient algorithm, VME-DWT, to remove eye blinks in a short segment of the single EEG channel. Method: The proposed algorithm: (a) locates eye blink intervals using Variational Mode Extraction (VME) and (b) filters only contaminated EEG interval using an automatic Discrete Wavelet Transform (DWT) algorithm. The performance of VME-DWT is compared with an automatic Variational Mode Decomposition (AVMD) and a DWT-based algorithms, proposed for suppressing eye blinks in a short segment of the single EEG channel. Results: The VME-DWT detects and filters 95% of the eye blinks from the contaminated EEG signals with SNR ranging from -8 to +3 dB. The VME-DWT shows superiority to the AVMD and DWT with the higher mean value of correlation coefficient (0.92 vs. 0.83, 0.58) and lower mean value of RRMSE (0.42 vs. 0.59, 0.87). Significance: The VME-DWT can be a suitable algorithm for removal of eye blinks in low-cost single-channel EEG systems as it is: (a) computationally-efficient, the contaminated EEG signal is filtered in millisecond time resolution, (b) automatic, no human intervention is required, (c) low-invasive, EEG intervals without contamination remained unaltered, and (d) low-complexity, without need to the artifact reference.
14 July 2021 in IEEE Journal of Biomedical and Health Informatics
Objective: Blink-related features derived from electroencephalography (EEG) have recently arisen as a meaningful measure of drivers cognitive state. Combined with band power features of low-channel prefrontal EEG data, blink-derived features enhance the detection of driver drowsiness. Yet, it remains unanswered whether synergy of combined blink and EEG band power features for the detection of driver drowsiness may be further boosted if a proper eye blink removal is also applied before EEG analysis. This paper proposes an algorithm for simultaneous eye blink feature extraction and elimination from low-channel prefrontal EEG data. Methods: Firstly, eye blink intervals (EBIs) are identified from the Fp1 EEG channel using variational mode extraction, and then blink-related features are derived. Secondly, the identified EBIs are projected to the rest of EEG channels and then filtered by a combination of principal component analysis and discrete wavelet transform. Thirdly, a support vector machine with 10-fold cross-validation is employed to classify alert and drowsy states from the derived blink and filtered EEG band power features. Main results: When compared the synergy of eye blink and EEG features before and after filtering by the proposed algorithm, a significant improvement in the mean accuracy of driver drowsiness detection was achieved (71.2% vs. 78.1%, p<0.05). Significance: This paper validates a novel view of eye blinks as both a source of information and artifacts in EEG-based driver drowsiness detection.
14 April 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Objective : The driver fatigue detection using multi-channel electroencephalography (EEG) has been extensively addressed in the literature. However, the employment of a single prefrontal EEG channel should be prioritized as it provides users with more comfort. Furthermore, eye blinks from such channel can be analyzed as the complementary information. Here, we present a new driver fatigue detection method based on simultaneous EEG and eye blinks analysis using an Fp1 EEG channel. Methods : First, the moving standard deviation algorithm identifies eye blink intervals (EBIs) to extract blink-related features. Second, the discrete wavelet transform filters the EBIs from the EEG signal. Third, the filtered EEG signal is decomposed into sub-bands, and various linear and nonlinear features are extracted. Finally, the prominent features are selected by the neighbourhood components analysis and fed to a classifier to discriminate between fatigue and alert driving. In this paper, two different databases are investigated. The first one is used for parameters’ tuning of proposed method for the eye blink detection and filtering, nonlinear EEG measures, and feature selection. The second one is solely used for testing the robustness of the tuned parameters. Main results : The comparison between the obtained results from both databases by the AdaBoost classifier in terms of sensitivity (90.2% vs. 87.4%), specificity (87.7% vs. 85.5%), and accuracy (88.4% vs. 86.8%) indicates the reliability of the proposed method for the driver fatigue detection. Significance : Considering the existence of commercial single prefrontal channel EEG headbands, the proposed method can be used to detect the driver fatigue in real-world scenarios.
The electroencephalogram signal (EEG) often suffers from various artifacts and noises that have physiological and non-physiological origins. Among these artifacts, eye blink, due to its amplitude is considered to have the most influence on EEG analysis. In this paper, a low complexity approach based on Stationary Wavelet Transform (SWT) and skewness is proposed to remove eye blink artifacts from EEG signals. The proposed method is compared against Automatic Wavelet Independent Components Analysis (AWICA) and Enhanced AWICA. Normalized Root Mean Square Error (NRMSE), Peak Signal-to-Noise Ratio (PSNR), and correlation coefficient ( ) between filtered and pure EEG signals are utilized to quantify artifact removal performance. The proposed approach shows smaller NRMSE, larger PSNR, and larger correlation coefficient values compared to the other methods. Furthermore, the speed of execution of the proposed method is considerably faster than other methods, which makes it more suitable for real-time processing.
Objective: The early prediction of preterm labor can significantly minimize premature delivery complications for both the mother and infant. The aim of this research is to propose an automatic algorithm for the prediction of preterm labor using a single electrohysterogram (EHG) signal. Method: The proposed method firstly employs empirical mode decomposition (EMD) to split the EHG signal into two intrinsic mode functions (IMFs), then extracts sample entropy (SampEn), the root mean square (RMS), and the mean Teager–Kaiser energy (MTKE) from each IMF to form the feature vector. Finally, the extracted features are fed to a k-nearest neighbors (kNN), support vector machine (SVM), and decision tree (DT) classifiers to predict whether the recorded EHG signal refers to the preterm case. Main results: The studied database consists of 262 term and 38 preterm delivery pregnancies, each with three EHG channels, recorded for 30 min. The SVM with a polynomial kernel achieved the best result, with an average sensitivity of 99.5%, a specificity of 99.7%, and an accuracy of 99.7%. This was followed by DT, with a mean sensitivity of 100%, a specificity of 98.4%, and an accuracy of 98.7%. Significance: The main superiority of the proposed method over the state-of-the-art algorithms that studied the same database is the use of only a single EHG channel without using either synthetic data generation or feature ranking algorithms.
Objective: Although a wide range of researches have shown the utility of electroencephalography (EEG) for the sleep monitoring, the majority of them reported a low sensitivity for classification of wakefulness from sleep stage I. This paper, therefore, validates a reliable nonlinear feature set for discriminating the wakefulness from sleep stage I using a single frontal EEG channel. Methods : Effectiveness of the proposed feature set was evaluated using four public databases namely Sleep Telemetry, DREAMS, MESA, and DCSM. After splitting the EEG signal into its sub-bands using discrete wavelet transform, Katz and Higuchi’s fractal dimensions, dispersion entropy, and bubble entropy were computed as the features. Then, 70% of the samples was randomly fed to the support vector machine, linear discriminant analysis, and k-nearest neighbors classifiers with 10-fold cross-validation for the training, whereas the rest was used for the unseen data testing. We also compared performance of the proposed feature set against the relative band power (RBP) analysis. Results : While the best classification results for both feature sets were achieved by the support vector machine, the proposed outperformed the RBP with the higher mean of sensitivity to sleep stage I for the Sleep Telemetry (82.6% vs. 71.8%, ${p} < 0.05$ ), DREAMS (87.6% vs. 71.8%, ${p} < 0.05$ ), DCSM (91.0% vs. 74.2%, ${p} < 0.05$ ), and MESA (82.0% vs. 76.1%, ${p} < 0.05$ ) databases. Significance : Considering interchangeability of the proposed feature set for discriminating the wakefulness from sleep stage I, it has the potential to be used for estimating the sleep onset latency in clinical applications.