Coronavirus disease 2019 (COVID-19) has emerged as a pandemic with serious clinical manifestations including death. A pandemic at the large-scale like COVID-19 places extraordinary demands on the world's health systems, dramatically devastates vulnerable populations, and critically threatens the global communities in an unprecedented way. While tremendous efforts at the frontline are placed on detecting the virus, providing treatments and developing vaccines, it is also critically important to examine the technologies and systems for tackling disease emergence, arresting its spread and especially the strategy for diseases prevention. The objective of this article is to review enabling technologies and systems with various application scenarios for handling the COVID-19 crisis. The article will focus specifically on 1) wearable devices suitable for monitoring the populations at risk and those in quarantine, both for evaluating the health status of caregivers and management personnel, and for facilitating triage processes for admission to hospitals; 2) unobtrusive sensing systems for detecting the disease and for monitoring patients with relatively mild symptoms whose clinical situation could suddenly worsen in improvised hospitals; and 3) telehealth technologies for the remote monitoring and diagnosis of COVID-19 and related diseases. Finally, further challenges and opportunities for future directions of development are highlighted.
11 June 2020 in IEEE Transactions on Industrial Informatics
In this work, we propose a novel neuromuscular password-based user authentication method. The method consists of two parts: surface electromyogram (sEMG)-based finger muscle isometric contraction password (FMICP) and neuromuscular biometrics. FMICP can be entered through isometric contraction of different finger muscles in a prescribed order without actual finger movement, which makes it difficult for observers to obtain the password. In our study, the isometric contraction patterns of different finger muscles were recognized through high-density sEMG (HD-sEMG) signals acquired from the right dorsal hand. Moreover, both 1) time-frequency-space domain features at macroscopic level (interference-pattern EMG) and 2) motor neuron firing rate features at microscopic level (via decomposition) were extracted to represent neuromuscular biometrics, serving as a second defense. The FMICP and macro-micro neuromuscular biometrics together form a neuromuscular password. The proposed neuromuscular password achieved an equal error rate (EER) of 0.0128 when impostors entered a wrong FMICP. Even when impostors entered the correct FMICP, the neuromuscular biometrics, as the second defense, inhibited impostors with an EER of 0.1496. To the best of our knowledge, this is the first study to use individually-unique neuromuscular information during unobservable muscle isometric contractions for user authentication, with training and testing data acquired on different days.
Physiological features extraction from Motion Artifacts (MA) corrupted Photoplethysmography (PPG) signals are of great difficulty due to the non-linear interaction between clean PPG and noise. To accurately extract features such as heart rate, blood pressure, and Oxygen Saturation in Blood, a robust PPG de-noising and waveform recovering method is required. However, traditional adaptive filtering or signal decomposition methods fail to achieve this goal. In this paper, a Signal-Noise Interaction modeling based algorithm for motion artifacts removal (SniMA) under strenuous physical exercise utilizing Envelope Filtering (EF) and Time-Delay Neural Network (TDNN) is proposed. Envelope Filtering normalizes raw data and eliminates imbalance training problem for neural networks, while TDNN is a hidden-state included method aiming at modeling PPG signal-noise interaction. An accelerometer as well as a gyroscope functions as the noise reference. Results comparing 8 performance indexes extracted from 4 types of waveform related features (heart rate, waveform correlation, pulse width, and pulse area) on an open access dataset we built show SniMA’s effectiveness for PPG MA removal. The proposed algorithm provides a significant improvement in PPG waveform recovery and PPG feature estimation accuracy. This is the first time that a TDNN has been introduced for PPG de-noising. This study also indicates the potential of other hidden-state involved signal-noise interaction modeling methods for PPG de-noising.
29 September 2020 in IEEE Journal of Biomedical and Health Informatics
With the soaring development of body sensor network (BSN)-based health informatics, information security in such medical devices has attracted increasing attention in recent years. Employing the biosignals acquired directly by the BSN as biometrics for personal identification is an effective approach. Noncancelability and cross-application invariance are two natural flaws of most traditional biometric modalities. Once the biometric template is exposed, it is compromised forever. Even worse, because the same biometrics may be employed as tokens for different accounts in multiple applications, the exposed template can be used to compromise other accounts. In this work, we propose a cancelable and cross-application discrepant biometric approach based on high-density surface electromyogram (HD-sEMG) for personal identification. We enrolled two accounts for each user. HD-sEMG signals from the right dorsal hand under isometric contractions of different finger muscles were employed as biometric tokens. Since isometric contraction, in contrast to dynamic contraction, requires no actual movement, the users' choice to login to different accounts is greatly protected against impostors. We realized a promising identification accuracy of 85.8% for 44 identities (22 subjects × 2 accounts) with training and testing data acquired 9 days apart. The high identification accuracy of different accounts for the same user demonstrates the promising cancelability and cross-application discrepancy of the proposed HD-sEMG-based biometrics. To the best of our knowledge, this is the first study to employ HD-sEMG in personal identification applications, with signal variation across days considered.
For long-term and more convenience electrocardiograph (ECG) monitoring, an active- electrode-based ECG monitoring system, which can measure ECG through clothes, is proposed in this paper. The hardware of the system includes active electrodes, signal processing and data transmission modules and the software mainly includes a denoising algorithm based on empirical mode decomposition (EMD). Then the proposed system was verified using the comparison of the ECG signals measured synchronously by active electrodes and Ag/AgCl electrodes. In addition, three flexible materials, including conductive textile, copper foil tape and a flexible printed circuit (FPC) are developed for the sensing layer with active electrodes. To compare the performance of these three materials for the sensing layer, the ECG signals of 10 subjects were measured by different materials in three postures and several indexes for quality evaluation were calculated. Results show that effective and clear ECG waveforms can be measured by all three kinds of materials and the quality of ECG signals measured by FPC is the best by conducting a significant t-test for signal quality indexes of three materials.
20 April 2020 in IEEE Transactions on Industrial Informatics
Photoplethysmography (PPG) has shown its great potential for noninvasive health monitoring, but its application in wearable devices is largely impeded due to its extreme vulnerability to motion artifacts. In this study, we proposed a new stochastic modeling based nonlinear Bayesian filtering framework for recovery of corrupted PPG waveform under strenuous physical exercise in wearable health-monitoring devices. A deep Recurrent Neural Network was first recruited for accurate cardiac-period segmentation of corrupted PPG signals. Then, a stochastic model was applied to extract waveform details from clean PPG pulses, and was further derived into a system-state space. Following this was an extended Kalman filter using the state space structured by modeling. Covariance of measurement noise was estimated by motion related information to adjust it into real physical environment adaptively. Comparison results with state-of-the-art methods on a wearable-device based 48-subject dataset showed the outstanding performance of the proposed de-noising framework, with period-segmentation sensitivity and precision higher than 99.1%, instantaneous heart rate error lower than 2 beats/min, average heart rate error down to 1.14 beats/min, and recovery accuracy of waveform details significantly improved (p<0.05). This framework is the first PPG de-noising strategy that introduces waveform-modeling methods to ensure detail recovery, and a great example of algorithm fusion between stochastic signal processing and emerging deep learning methods for time-sequential biomedical signal processing.