Vera Chernonosova

Dr. Vera Chernonosova

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Pryadko ArtyomPryadko Artyom
Pryadko Artyom
VBVladimir Botvin
Vladimir Botvin
YMYulia Mukhortova
Yulia Mukhortova
IPIgor Pariy
Igor Pariy
Dmitry WagnerDmitry Wagner
Dmitry Wagner
Roman SurmenevRoman Surmenev
Roman Surmenev
Novel hybrid magnetoactive composite scaffolds based on poly(3-hydroxybutyrate) (PHB), gelatin, and magnetite (Fe3O4) were fabricated by electrospinning. The morphology, structure, phase composition, and magnetic properties of composite scaffolds were studied. Fabrication procedures of PHB/gelatin and PHB/gelatin/Fe3O4 scaffolds resulted in the formation of both core-shell and ribbon-shaped structure of the fibers. In case of hybrid PHB/gelatin/Fe3O4 scaffolds submicron-sized Fe3O4 particles were observed in the surface layers of the fibers. The X-ray photoelectron spectroscopy results allowed the presence of gelatin on the fiber surface (N/C ratio–0.11) to be revealed. Incubation of the composite scaffolds in saline for 3 h decreased the amount of gelatin on the surface by more than ~75%. The differential scanning calorimetry results obtained for pure PHB scaffolds revealed a characteristic melting peak at 177.5 °C. The presence of gelatin in PHB/gelatin and PHB/gelatin/Fe3O4 scaffolds resulted in the decrease in melting temperature to 168–169 °C in comparison with pure PHB scaffolds due to the core-shell structure of the fibers. Hybrid scaffolds also demonstrated a decrease in crystallinity from 52.3% (PHB) to 16.9% (PHB/gelatin) and 9.2% (PHB/gelatin/Fe3O4). All the prepared scaffolds were non-toxic and saturation magnetization of the composite scaffolds with magnetite was 3.27 ± 0.22 emu/g, which makes them prospective candidates for usage in biomedical applications.

2 December 2016 in Polymers for Advanced Technologies
Verified
Journal Article
Closed access
PDF file
VCVera Chernonosova
Vera Chernonosova
RKRen I. Kvon
Ren I. Kvon
ASAlena O. Stepanova
Alena O. Stepanova
Yurii LarichevYurii Larichev
Yurii Larichev
AKAndrey Karpenko
Andrey Karpenko
PLPavel P. Laktionov
Pavel P. Laktionov

Verified
Journal Article
Open access
PDF file
VCVera Chernonosova
Vera Chernonosova
IKIlya E. Kuzmin
Ilya E. Kuzmin
ISInna Kazimirovna Shundrina
Inna Kazimirovna Shundrina
MKMikhail V. Korobeynikov
Mikhail V. Korobeynikov
VGVictor Golyshev
Victor Golyshev
PLPavel P. Laktionov
Pavel P. Laktionov
Fibrous polyurethane-based scaffolds have proven to be promising materials for the tissue engineering of implanted medical devices. Sterilization of such materials and medical devices is an absolutely essential step toward their medical application. In the presented work, we studied the effects of two sterilization methods (ethylene oxide treatment and electron beam irradiation) on the fibrous scaffolds produced from a polyurethane-gelatin blend. Scaffold structure and properties were studied by scanning electron microscopy (SEM), atomic force microscopy (AFM), infrared spectroscopy (FTIR), a stress-loading test, and a cell viability test with human fibroblasts. Treatment of fibrous polyurethane-based materials with ethylene oxide caused significant changes in their structure (formation of glued-like structures, increase in fiber diameter, and decrease in pore size) and mechanical properties (20% growth of the tensile strength, 30% decline of the maximal elongation). All sterilization procedures did not induce any cytotoxic effects or impede the biocompatibility of scaffolds. The obtained data determined electron beam irradiation to be a recommended sterilization method for electrospun medical devices made from polyurethane-gelatin blends.

26 June 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
VCVera Chernonosova
Vera Chernonosova
AGAlexander Gostev
Alexander Gostev
YGYun Gao
Yun Gao
YCYuriy A. Chesalov
Yuriy A. Chesalov
ASAlexey V. Shutov
Alexey V. Shutov
PLPavel P. Laktionov
Pavel P. Laktionov
Properties of matrices manufactured by electrospinning from solutions of polyurethane Tecoflex EG-80A with gelatin in 1,1,1,3,3,3-hexafluoroisopropanol were studied. The concentration of gelatin added to the electrospinning solution was shown to influence the mechanical properties of matrices: the dependence of matrix tensile strength on protein concentration is described by a bell-shaped curve and an increase in gelatin concentration added to the elasticity of the samples. SEM, FTIR spectroscopy, and mechanical testing demonstrate that incubation of matrices in phosphate buffer changes the structure of the fibers and alters the polyurethane-gelatin interactions, increasing matrix durability. The ability of the matrices to maintain adhesion and proliferation of human endothelial cells was studied. The results suggest that matrices made of 3% polyurethane solution with 15% gelatin (wt/wt) and treated with glutaraldehyde are the optimal variant for cultivation of endothelial cells.

7 April 2020 in Polymers
Verified
Journal Article
Open access
PDF file
AGAlexander Gostev
Alexander Gostev
ISInna K. Shundrina
Inna K. Shundrina
VPVitaliy I. Pastukhov
Vitaliy I. Pastukhov
ASAlexey V. Shutov
Alexey V. Shutov
VCVera Chernonosova
Vera Chernonosova
PLPavel P. Laktionov
Pavel P. Laktionov
The biostability of the polyurethanes Tecoflex EG-80A and Pellethane 2363-80A, used as basic polymers of the vascular grafts (VGs) produced by electrospinning, as well as the tensile strength of Tecoflex VGs, are studied. Solutions of Tecoflex or Pellethane with gelatin and bivalirudin in 1,1,1,3,3,3-hexafluoroisopropanol are used for VG production. After 1, 12, and 24 weeks of VG implantation in the infrarenal position of the abdominal aorta of Wistar rats, VGs are explanted, fixed in formalin, freed from outer tissues, dialyzed, and dried. The polyurethanes are extracted from VGs by dispersion/extraction in tetrahydrofuran (THF) and freed from the excess of THF-insoluble biopolymers. The stability of polyurethanes is assessed by IR spectroscopy and gel permeation chromatography. Pellethane has emerged to be stable at all experimental points. Tecoflex loses approximately 10% of its molecular weight (both Mn and Mw) after 3 months and restored its initial value within 6 months of its functioning as a graft. Mechanical testing demonstrates a 30% reduction in the tensile strength after 3 months in VG and a 10% increase after 6 months. The stability and mechanical properties of polyurethane-based VGs demonstrate their utility for the reconstitution of damaged arteries.

23 December 2019 in Biomedical Materials
Verified
Journal Article
Open access
PDF file
AGAlexander Gostev
Alexander Gostev
VCVera Chernonosova
Vera Chernonosova
IMIvan S Murashov
Ivan S Murashov
David SergeevichevDavid Sergeevichev
David Sergeevichev
AKAlexander A Korobeinikov
Alexander A Korobeinikov
PLPavel P Laktionov
Pavel P Laktionov
General physicochemical properties of the vascular grafts (VGs) produced from the solutions of Tecoflex (Tec) with gelatin (GL) and bivalirudin (BV) by electrospinning are studied. The electrospun VGs of Tec-GL-BV and expanded polytetrafluoroethylene (e-PTFE) implanted in the abdominal aorta of 36 Wistar rats have been observed over different time intervals up to 24 weeks. A comparison shows that 94.5% of the Tec-GL-BV VGs and only 66.6% of e-PTFE VGs (р = 0.0438) are free of occlusions after a 6 month implantation. At the intermediate observation points, Tec-GL-BV VGs demonstrate severe neovascularization of the VG neoadventitial layer as compared with e-PTFE grafts. A histological examination demonstrates a small thickness of the neointima layer and a low level of calcification in Tec-GL-BV VGs as compared with the control grafts. Thus, polyurethane-based protein-enriched VGs have certain advantages over e-PTFE VGs, suggesting their utility in clinical studies.