David Sergeevichev

Dr. David Sergeevichev

Meshalkin National Medical Research Center, Novosibirsk, Novosibirskaya Oblast’, Russia
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Heart Rhythm
Verified
Journal Article
Closed access
ARAlexander Romanov
Alexander Romanov
EPEvgeny Pokushalov
Evgeny Pokushalov
DPDmitry Ponomarev
Dmitry Ponomarev
SBSevda Bayramova
Sevda Bayramova
VSVitaliy Shabanov
Vitaliy Shabanov
JSJonathan S. Steinberg
Jonathan S. Steinberg

1 December 2015 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
PDF file
EPEvgeny Pokushalov
Evgeny Pokushalov
BKBoris Kozlov
Boris Kozlov
ARAlexander Romanov
Alexander Romanov
ASArtem Strelnikov
Artem Strelnikov
SBSevda Bayramova
Sevda Bayramova
JSJonathan S. Steinberg
Jonathan S. Steinberg
Background—: Animal models suggest that the neurotransmitter inhibitor, botulinum toxin, when injected into the epicardial fat pads can suppress atrial fibrillation inducibility. The aim of this prospective randomized double-blind study was to compare the efficacy and safety of botulinum toxin injection into epicardial fat pads for preventing atrial tachyarrhythmias. Methods and Results—: Patients with history of paroxysmal atrial fibrillation and indication for coronary artery bypass graft surgery were randomized to botulinum toxin (Xeomin, Merz, Germany; 50 U/1 mL at each fat pad; n=30) or placebo (0.9% normal saline, 1 mL at each fat pad; n=30) injection into epicardial fat pads during surgery. Patients were followed for 1 year to assess maintenance of sinus rhythm using an implantable loop recorder. All patients in both groups had successful epicardial fat pad injections without complications. The incidence of early postoperative atrial fibrillation within 30 days after coronary artery bypass graft was 2 of 30 patients (7%) in the botulinum toxin group and 9 of 30 patients (30%) in the placebo group ( P =0.024). Between 30 days and up to the 12-month follow-up examination, 7 of the 30 patients in the placebo group (27%) and none of the 30 patients in the botulinum toxin group (0%) had recurrent atrial fibrillation ( P =0.002). There were no complications observed during the 1-year follow-up. Conclusions—: Botulinum toxin injection into epicardial fat pads during coronary artery bypass graft provided substantial atrial tachyarrhythmia suppression both early as well as during 1-year follow-up, without any serious adverse events. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01842529.

1 August 2014 in JACC
Verified
Journal Article
Closed access
EPEvgeny Pokushalov
Evgeny Pokushalov
BKBoris Kozlov
Boris Kozlov
ARAlexander Romanov
Alexander Romanov
ASArtem Strelnikov
Artem Strelnikov
SBSevda Bayramova
Sevda Bayramova
JSJonathan S. Steinberg
Jonathan S. Steinberg

2 November 2016 in Nanomedicine: Nanotechnology, Biology and Medicine
Verified
Journal Article
Closed access
PDF file
AKAnna A. Krasilnikova
Anna A. Krasilnikova
Anastasiya SolovievaAnastasiya Solovieva
Anastasiya Solovieva
AIAnton A. Ivanov
Anton A. Ivanov
KTKristina E. Trifonova
Kristina E. Trifonova
TPTatiana Pozmogova
Tatiana Pozmogova
LSLidiya V. Shestopalova
Lidiya V. Shestopalova

23 December 2019 in Biomedical Materials
Verified
Journal Article
Open access
PDF file
AGAlexander Gostev
Alexander Gostev
VCVera Chernonosova
Vera Chernonosova
IMIvan S Murashov
Ivan S Murashov
David SergeevichevDavid Sergeevichev
David Sergeevichev
AKAlexander A Korobeinikov
Alexander A Korobeinikov
PLPavel P Laktionov
Pavel P Laktionov
General physicochemical properties of the vascular grafts (VGs) produced from the solutions of Tecoflex (Tec) with gelatin (GL) and bivalirudin (BV) by electrospinning are studied. The electrospun VGs of Tec-GL-BV and expanded polytetrafluoroethylene (e-PTFE) implanted in the abdominal aorta of 36 Wistar rats have been observed over different time intervals up to 24 weeks. A comparison shows that 94.5% of the Tec-GL-BV VGs and only 66.6% of e-PTFE VGs (р = 0.0438) are free of occlusions after a 6 month implantation. At the intermediate observation points, Tec-GL-BV VGs demonstrate severe neovascularization of the VG neoadventitial layer as compared with e-PTFE grafts. A histological examination demonstrates a small thickness of the neointima layer and a low level of calcification in Tec-GL-BV VGs as compared with the control grafts. Thus, polyurethane-based protein-enriched VGs have certain advantages over e-PTFE VGs, suggesting their utility in clinical studies.

4 August 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Nikita A. KuznetsovNikita A. Kuznetsov
Nikita A. Kuznetsov
IMIvan Murashov
Ivan Murashov
VCVera Chernonosova
Vera Chernonosova
BCBoris P. Chelobanov
Boris P. Chelobanov
ASAlena Stepanova
Alena Stepanova
PLPavel P. Laktionov
Pavel P. Laktionov
A stenting procedure aimed at blood flow restoration in stenosed arteries significantly improves the efficiency of vascular surgery. However, the current challenge is to prevent neointimal growth, which reduces the vessel lumen, in the stented segments in the long run. We tested in vivo drug-eluting coating applied by electrospinning to metal vascular stents to inhibit the overgrowth of neointimal cells via both the drug release and mechanical support of the vascular wall. The blend of polycaprolactone with human serum albumin and paclitaxel was used for stent coating by electrospinning. The drug-eluting stents (DESs) were placed using a balloon catheter to the rabbit common iliac artery for 1, 3, and 6 months. The blood flow rate was ultrasonically determined in vivo. After explantation, the stented arterial segment was visually and histologically examined. Any undesirable biological responses (rejection or hemodynamically significant stenosis) were unobservable in the experimental groups. DESs were less traumatic and induced weaker neointimal growth; over six months, the blood flow increased by 37% versus bare-metal stents, where it increased by at least double the rate. Thus, electrospun-coated DESs demonstrate considerable advantages over the bare-metal variants.