Hemostasis is vital to save lives, reducing risks of organ failure and hemorrhagic shock. Exploring novel hemostatic materials and precise monitoring of the hemostatic status is of great importance for efficient hemostasis. We present the development of chitosan–graphene oxide-based hemostatic composite and multi-scale photoacoustic evaluation of the hemostatic performance. The hemostatic sponge can quickly and efficiently absorb the blood with its porous cavity and specific surficial property. We inspect the hemostatic performance via an in vitro blood absorption test and in vivo mouse bleeding injury experiments. Results show that the synthesized hemostatic sponge can not only absorb plasma in blood fast with its interior porous structure but also stimulate the interfacial reaction with erythrocytes and platelets. The superiority of multi-scale photoacoustic imaging for guiding, monitoring, and evaluating the hemostatic stages of sponges is demonstrated with high spatial resolution and great sensitivity at depths. Photoacoustic evaluation of a chitosan–graphene oxide-based hemostatic sponge has the potential to be transferred toward the clinical assessment of wound healing.
Optical resolution photoacoustic microscopy (OR-PAM) provides high-resolution, label-free and non-invasive functional imaging for broad biomedical applications. Dual-polarized fiber laser sensors have high sensitivity, low noise, a miniature size, and excellent stability; thus, they have been used in acoustic detection in OR-PAM. Here, we review recent progress in fiber-laser-based ultrasound sensors for photoacoustic microscopy, especially the dual-polarized fiber laser sensor with high sensitivity. The principle, characterization and sensitivity optimization of this type of sensor are presented. In vivo experiments demonstrate its excellent performance in the detection of photoacoustic (PA) signals in OR-PAM. This review summarizes representative applications of fiber laser sensors in OR-PAM and discusses their further improvements.
Interventional ultrasound (US) has challenges in accurate localization of the puncture needle due to intrinsic acoustic interferences, which lead to blurred, indistinct, and even invisible needles in handheld linear array transducer-based US navigation, especially the incorrect needle tip positioning. Photoacoustic (PA) imaging can provide complementary image contrast, without additional data acquisition. Herein, we proposed an internal illumination to solely light up the needle tip in PA imaging. Then deep-learning-based feature segmentation alleviates acoustic interferences, enhancing the needle shaft-tip visibility. Further, needle shaft-tip compensation aligned the needle shaft in US image and the needle tip in the PA image. The experiments on phantom, ex vivo chicken breast, preclinical radiofrequency ablation and in vivo biopsy of sentinel lymph nodes were piloted. The target registration error can reach the submillimeter level, achieving precise puncture needle tracking ability with in-plane US/PA navigation.
1 July 2018 in Journal of Innovative Optical Health Sciences
The synthetic aperture-based linear-array photoacoustic tomography (PAT) was proposed to address the limited-view shortcomings of the single aperture, but the detection field of view (FOV) determined by the aperture orientation effect was not fully considered yet, leading to the limited-view observation and image resolution degradation. Herein, the aperture orientation effect was proposed from the theoretical model and then it was verified via both the numerical simulation and phantom experiment. Different orientations were enumerated sequentially in the simulation to approximate the ideal full-view case for the optimal detection FOV, considering the detection pattern of the linear-array transducer. As a result, the corresponding optimal aperture orientation was 60 if the synthetic aperture was seamlessly established by three single linear arrays, where the overlapped detection pattern was optimized from the individual linear-array transducer at the adjacent positions. Therefore, the limited-view artifacts were minimized and the image resolution was enhanced in this aperture orientation. This study showed that the aperture orientation had great influence on the optimal detection FOV in the synthetic aperture configuration, where the full-view imaging quality and enhanced image resolution could be achieved.
Ultrasound computed tomography (USCT) can visualize a target with multiple imaging contrasts, which were demonstrated individually previously. Here, to improve the imaging quality, the dynamic speed of sound (SoS) map derived from the transmission USCT will be adapted for the correction of the acoustic speed variation in the reflection USCT. The variable SoS map was firstly restored via the optimized simultaneous algebraic reconstruction technique with the time of flights selected from the transmitted ultrasonic signals. Then, the multi-stencils fast marching method was used to calculate the delay time from each element to the grids in the imaging field of view. Finally, the delay time in conventional constant-speed-assumed delay and sum (DAS) beamforming would be replaced by the practical computed delay time to achieve higher delay accuracy in the reflection USCT. The results from the numerical, phantom, and in vivo experiments show that our approach enables multi-modality imaging, accurate target localization, and precise boundary detection with the full-view fast imaging performance. The proposed method and its implementation are of great value for accurate, fast, and multi-modality USCT imaging, particularly suitable for highly acoustic heterogeneous medium.
18 April 2016 in Journal of Neurological Surgery Part A: Central European Neurosurgery
Objective The closure of chronic wounds after skull defect reconstruction with titanium mesh is one of the most challenging problems for plastic and reconstructive surgeons. Current approaches are disappointing. Methods In 10 patients, we explored the role of acellular dermal matrix (ADM) in combination with autologous skin grafts (ASGs) for closure of chronic wounds after skull reconstruction with titanium. Results ADM and ASG survived in all patients. Grade A healing (healing well without defect) was achieved. The average operating time was 30 to 45 minutes, and the average blood loss 30 to 50 mL. After 3 months, the wound was still closed in all patients. Conclusion The combination of ADM plus ASG obtained a high wound closure rate. ADM plus ASG allows avoiding other procedures such as rotational flaps and free flaps that require more operating time, special equipment, and adequate training.