As magneto-acoustic-electrical tomography (MAET) combines the merits of high contrast and high imaging resolution, and is extremely useful for electrical conductivity measurement, so it is expected to be a promising medical imaging modalities for diagnosis of early-stage cancer. Based on the Verasonics system and the MC600 displacement platform, we designed and implemented a MAET system with a chirp pulse stimulation (MAET-CPS) method and a focal probe was utilized for stepscan focus excitation to enhance the imaging resolution. The relevant experiments were conducted to explore the influence of excitation positions of the single-focus point, and the effect of the excitation position on the amplitudes of the conductivity variation was clearly demonstrated. In order to take advantage of the merits of multifocus imaging, we firstly proposed a single focus MAET system with a chirp pulse stimulation (sfMAET-CPS) method and a multifocus MAET system with a chirp pulse stimulation (mfMAET-CPS) method for high-resolution conductivity imaging, and a homogenous gelatin phantom with a cuboid-shaped hole was used to investigate the accuracy of mfMAET-CPS. Comparative experiments were carried out on the same uniform phantom by the sfMAET-CPS and the mfMAET-CPS, respectively. The results showed that: (1) the electrical conductivity distributions of the homogenous phantom with a cuboid-shaped hole were detected by the sfMAET-CPS but were easily affected by the focal point, which demonstrated that the sfMAET-CPS had a low imaging resolution. (2) Compared with the sfMAET-CPS, the imaging effect of the mfMAET-CPS was much better than that of the sfMAET-CPS. (3) A linear interpolation algorithm was used to process the 2D conductivity distribution; it increased the smoothness of the conductivity distribution and improved the imaging effect. The stepscan focus excitation and the linearly frequency-modulated theory provide an alternative scheme for the clinical application of MAET.
4 February 2022 in IEEE Transactions on Biomedical Engineering
The mechanical and electrical properties of soft tissues are relative to soft tissues’ pathological state. Modern medical imaging devices have shown a trend to multi-modal imaging, which will provide complementary functional information to improve the accuracy of disease diagnosis. However, no method or system can simultaneously measure the mechanical and electrical properties of the soft tissue. In this study, we proposed a novel dual-modal imaging method integrated by shear wave elasticity imaging (SWEI) and Magneto-acousto-electrical tomography (MAET) to measure soft tissue's elasticity and conductivity simultaneously. A dual-modal imaging system based on a linear array transducer is built, and the imaging performances of MAET and SWEI were respectively evaluated by phantoms experiment and in vitro experiment. Conductivity phantom experiments show that the MAET in this dual-modal system can image conductivity gradient as low as 0.4 S/m. The phantom experiments show that the reconstructed 2-D elasticity maps of the phantoms with inclusions with a diameter larger than 5 mm are relatively accurate. In vitro experiments show that the elasticity parameter can significantly distinguish the changes in tissue before and after heating. This study first proposes a method that can simultaneously obtain tissue elasticity and electrical conductivity to the best of our knowledge. Although this paper just carried out the proof of concept experiments of the new method, it demonstrates great potential for disease diagnosis in the future.
1 January 1990 in International Journal of Control
Using a sufficient algebraic stability criterion for polynomials, an algorithm is deduced for the design of dynamic feedback which simultaneously stabilizes a set of single-input systems. The application of this algorithm to the stabilization problem of an aircraft is also presented.
8 November 2022 in IEEE Transactions on Biomedical Engineering
As a tissue conductivity imaging method, magneto-acousto-electric tomography (MAET) has the advantage of high axial spatial resolution compared with traditional electrical impedance imaging methods. However, it has the problems of difficulty in imaging targets with irregular conductivity distribution and poor lateral spatial resolution. Although the rotation-based MAET method can partly solve the irregular target problem, there is still a poor imaging signal-to-noise ratio (SNR) problem. Our previous study established a framework of an innovative MAET method, which has a very similar imaging theory and reconstruction algorithm to those of computed tomography (CT). Therefore, we name the method magneto-acoustic-electric computed tomography (MAE-CT). This paper proposes an improved implementation of MAE-CT based on multi-angle plane wave excitation. This method combines the electronic steering of the linear array transducer with the mechanical rotation to increase the number of projection angles while keeping the imaging complexity. In this study, we first established a finite element simulation model to verify the method's feasibility. Then phantom experiments were conducted to systematically investigate the performance of the proposed method. Finally, in vitro liver tissue experiment was conducted to further explore the feasibility of the method. The experimental results show that our method improves both the SNR and spatial resolution of the reconstructed image. For the phantom results, this method can detect conductivity of 0.67 S/m in an area with a size of 2 mm. To the best of our knowledge, this is the best result of spatial resolution available for MAET.
12 September 2023 in IEEE Transactions on Biomedical Engineering
Magneto-acousto-electrical computed tomography (MAE-CT) is a recently developed rotational magneto-acousto-electrical tomography (MAET) method, which can map the conductivity parameter of tissues with high spatial resolution. Since the imaging mode of MAE-CT is similar to that of CT, the reconstruction algorithms for CT are possible to be adopted for MAE-CT. Previous studies have demonstrated that the filtered back-projection (FBP) algorithm, which is one of the most common CT reconstruction algorithms, can be used for MAE-CT reconstruction. However, FBP has some inherent shortcomings of being sensitive to noise and non-uniform distribution of views. In this study, we introduced iterative reconstruction (IR) method in MAE-CT reconstruction and compared its performance with that of the FBP. The numerical simulation, the phantom, and in vitro experiments were performed, and several IR algorithms (ART, SART, SIRT) were used for reconstruction. The results show that the images reconstructed by the FBP and IR are similar when the data is noise-free in the simulation. As the noise level increases, the images reconstructed by SART and SIRT are more robust to the noise than FBP. In the phantom experiment, noise and some stripe artifacts caused by the FBP are removed by SART and SIRT algorithms. In conclusion, the IR method used in CT is applicable in MAE-CT, and it performs better than FBP, which indicates that the state-of-the-art achievements in the CT algorithm can also be adopted for the MAE-CT reconstruction in the future.
Interventional ultrasound (US) has challenges in accurate localization of the puncture needle due to intrinsic acoustic interferences, which lead to blurred, indistinct, and even invisible needles in handheld linear array transducer-based US navigation, especially the incorrect needle tip positioning. Photoacoustic (PA) imaging can provide complementary image contrast, without additional data acquisition. Herein, we proposed an internal illumination to solely light up the needle tip in PA imaging. Then deep-learning-based feature segmentation alleviates acoustic interferences, enhancing the needle shaft-tip visibility. Further, needle shaft-tip compensation aligned the needle shaft in US image and the needle tip in the PA image. The experiments on phantom, ex vivo chicken breast, preclinical radiofrequency ablation and in vivo biopsy of sentinel lymph nodes were piloted. The target registration error can reach the submillimeter level, achieving precise puncture needle tracking ability with in-plane US/PA navigation.