Kenichi Funamoto

Prof. Kenichi Funamoto

Tohoku University
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2012 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
Kenichi FunamotoKenichi Funamoto
Kenichi Funamoto
IZIoannis K. Zervantonakis
Ioannis K. Zervantonakis
YLYuchun Liu
Yuchun Liu
COChristopher J. Ochs
Christopher J. Ochs
CKChoong Kim
Choong Kim
RKRoger D Kamm
Roger D Kamm
Low oxygen tensions experienced in various pathological and physiological conditions are a major stimulus for angiogenesis. Hypoxic conditions play a critical role in regulating cellular behaviour including migration, proliferation and differentiation. This study introduces the use of a microfluidic device that allows for the control of oxygen tension for the study of different three-dimensional (3D) cell cultures for various applications. The device has a central 3D gel region acting as an external cellular matrix, flanked by media channels. On each side, there is a peripheral gas channel through which suitable gas mixtures are supplied to establish a uniform oxygen tension or gradient within the device. The effects of various parameters, such as gas and media flow rates, device thickness, and diffusion coefficients of oxygen were examined using numerical simulations to determine the characteristics of the microfluidic device. A polycarbonate (PC) film with a low oxygen diffusion coefficient was embedded in the device in proximity above the channels to prevent oxygen diffusion from the incubator environment into the polydimethylsiloxane (PDMS) device. The oxygen tension in the device was then validated experimentally using a ruthenium-coated (Ru-coated) oxygen-sensing glass cover slip which confirmed the establishment of low uniform oxygen tensions (<3%) or an oxygen gradient across the gel region. To demonstrate the utility of the microfluidic device for cellular experiments under hypoxic conditions, migratory studies of MDA-MB-231 human breast cancer cells were performed. The microfluidic device allowed for imaging cellular migration with high-resolution, exhibiting an enhanced migration in hypoxia in comparison to normoxia. This microfluidic device presents itself as a promising platform for the investigation of cellular behaviour in a 3D gel scaffold under varying hypoxic conditions.

1 February 2015 in Journal of Biomechanics
Verified
Journal Article
Closed access
RKRyo Koizumi
Ryo Koizumi
Kenichi FunamotoKenichi Funamoto
Kenichi Funamoto
THToshiyuki Hayase
Toshiyuki Hayase
YKYusuke Kanke
Yusuke Kanke
MSMuneichi Shibata
Muneichi Shibata
TYTomoyuki Yambe
Tomoyuki Yambe

1 August 2012 in Cerebrovascular Diseases
Verified
Journal Article
Closed access
PDF file
OSOmodaka S
Omodaka S
SSShin-Ichirou Sugiyama
Shin-Ichirou Sugiyama
TITakashi Inoue
Takashi Inoue
Kenichi FunamotoKenichi Funamoto
Kenichi Funamoto
MFMiki Fujimura
Miki Fujimura
TTTeiji Tominaga
Teiji Tominaga
Background: Cerebral aneurysms carry a high risk of rupture and so present a major threat to the patient’s life. Accurate criteria for predicting aneurysm rupture are important for therapeutic decision-making, and some clinical and morphological factors may help to predict the risk for rupture of unruptured aneurysms, such as sex, size and location. Hemodynamic forces are considered to be key in the natural history of cerebral aneurysms, but the effect on aneurysm rupture is uncertain, and whether low or high wall shear stress (WSS) is the most critical in promoting rupture remains extremely controversial. This study investigated the local hemodynamic features at the aneurysm rupture point. Methods: Computational models of 6 ruptured middle cerebral artery aneurysms with intraoperative confirmation of rupture point were constructed from 3-dimensional rotational angiography images. Computational fluid dynamics (CFD) simulations were performed under pulsatile flows using patient-specific inlet flow conditions. Time-averaged WSS (TAWSS) and oscillatory shear index (OSI) were calculated, and compared at the rupture point and at the aneurysm wall without the rupture point. We performed an additional CFD simulation of a bleb-removed model for a peculiar case in which bleb formation could be confirmed by magnetic resonance angiography. Results: All rupture points were located at the body or dome of the aneurysm. The TAWSS at the rupture point was significantly lower than that at the aneurysm wall without the rupture point (1.10 vs. 4.96 Pa, p = 0.031). The OSI at the rupture point tended to be higher than at the aneurysm wall without the rupture point, although the difference was not significant (0.0148 vs. 0.0059, p = 0.156). In a bleb-removed simulation, the TAWSS at the bleb-removed area was 6.31 Pa, which was relatively higher than at the aneurysm wall (1.94 Pa). Conclusion: The hemodynamics of 6 ruptured cerebral aneurysms of the middle cerebral artery were examined using retrospective CFD analysis. We could confirm the rupture points in all cases. With those findings, local hemodynamics of ruptured aneurysms were quanti-tatively investigated. The rupture point is located in a low WSS region of the aneurysm wall. Bleb-removed simulation showed increased WSS of the bleb-removed area, associated with the flow impaction area. Although the number of subjects in this study was relatively small, our findings suggest that the location of the rupture point is related to a low WSS at the aneurysm wall. Further investigations will elucidate the detailed hemodynamic effects on aneurysm rupture.

17 May 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TFTomofumi Fushima
Tomofumi Fushima
ASAkiyo Sekimoto
Akiyo Sekimoto
TMTakahiro Minato
Takahiro Minato
TITakuya Ito
Takuya Ito
YOYuji Oe
Yuji Oe
NTNobuyuki Takahashi
Nobuyuki Takahashi
Preeclampsia (PE) is a pregnancy-induced hypertension with proteinuria that typically develops after 20 weeks of gestation. A reduction in uterine blood flow causes placental ischemia and placental release of anti-angiogenic factors such as sFlt-1 followed by PE. Although the reduced uterine perfusion pressure (RUPP) model is widely used in rats, investigating the role of genes on PE using genetically engineered animals has been problematic because it has been difficult to make a useful RUPP model in mice. To establish a RUPP model of PE in mice, we bilaterally ligated ovarian vessels distal to ovarian branches, uterine vessels, or both in ICR-strain mice at 14.5 days post coitum (dpc). Consequently, these mice had elevated BP, increased urinary albumin excretion, severe endotheliosis, and mesangial expansion. They also had an increased incidence of miscarriage and premature delivery. Embryonic weight at 18.5 dpc was significantly lower than that in sham mice. The closer to the ligation site the embryos were, the higher the resorption rate and the lower the embryonic weight. The phenotype was more severe in the order of ligation at the ovarian vessels < uterine vessels < both. Unlike the RUPP models described in the literature, this model did not constrict the abdominal aorta, which allowed BP to be measured with a tail cuff. This novel RUPP model in mice should be useful for investigating the pathogenesis of PE in genetically engineered mice and for evaluating new therapies for PE.

1 November 2012 in World Neurosurgery
Verified
Journal Article
Closed access
SSShin-Ichiro Sugiyama
Shin-Ichiro Sugiyama
HMHui Meng
Hui Meng
Kenichi FunamotoKenichi Funamoto
Kenichi Funamoto
TITakashi Inoue
Takashi Inoue
MFMiki Fujimura
Miki Fujimura
TTTeiji Tominaga
Teiji Tominaga

1 March 2020 in APL Bioengineering
Verified
Journal Article
Open access
PDF file
RKRei Koens
Rei Koens
YTYugo Tabata
Yugo Tabata
JSJean C. Serrano
Jean C. Serrano
SASatoshi Aratake
Satoshi Aratake
DYDaisuke Yoshino
Daisuke Yoshino
Kenichi FunamotoKenichi Funamoto
Kenichi Funamoto
Cells in a tumor microenvironment are exposed to spatial and temporal variations in oxygen tension due to hyperproliferation and immature vascularization. Such spatiotemporal oxygen heterogeneity affects the behavior of cancer cells, leading to cancer growth and metastasis, and thus, it is essential to clarify the cellular responses of cancer cells to oxygen tension. Herein, we describe a new double-layer microfluidic device allowing the control of oxygen tension and the behavior of cancer cells under spatiotemporal oxygen heterogeneity. Two parallel gas channels were located above the media and gel channels to enhance gas exchange, and a gas-impermeable polycarbonate film was embedded in the device to prevent the diffusion of atmospheric oxygen. Variations in oxygen tension in the device with the experimental parameters and design variables were investigated computationally and validated by using oxygen-sensitive nanoparticles. The present device can generate a uniform hypoxic condition at oxygen levels down to 0.3% O2, as well as a linear oxygen gradient from 3% O2 to 17% O2 across the gel channel within 15 min. Moreover, human breast cancer cells suspended in type I collagen gel were introduced in the gel channel to observe their response under controlled oxygen tension. Hypoxic exposure activated the proliferation and motility of the cells, which showed a local maximum increase at 5% O2. Under the oxygen gradient condition, the increase in the cell number was relatively high in the central mild hypoxia region. These findings demonstrate the utility of the present device to study cellular responses in an oxygen-controlled microenvironment.