Toshiyuki Hayase

Toshiyuki Hayase

Auto-generated profile, based on publicly available information

Toshiyuki Hayase

Institute of Fluid Science, Tohoku University, Sendai, Japan

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2015 in Journal of Biomechanics
Verified
Journal Article
Closed access
RKRyo Koizumi
Ryo Koizumi
Kenichi FunamotoKenichi Funamoto
Kenichi Funamoto
THToshiyuki Hayase
Toshiyuki Hayase
YKYusuke Kanke
Yusuke Kanke
MSMuneichi Shibata
Muneichi Shibata
TYTomoyuki Yambe
Tomoyuki Yambe

23 September 2015 in Fluid Dynamics Research
Verified
Journal Article
Closed access
PDF file
THToshiyuki Hayase
Toshiyuki Hayase

1 April 2005 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Kenichi FunamotoKenichi Funamoto
Kenichi Funamoto
THToshiyuki Hayase
Toshiyuki Hayase
ASAtsushi Shirai
Atsushi Shirai
YSYoshifumi Saijo
Yoshifumi Saijo
TYTomoyuki Yambe
Tomoyuki Yambe

21 May 2010 in Japanese Journal of Clinical Oncology
Verified
Journal Article
Open access
PDF file
KTKentaro Tamaki
Kentaro Tamaki
HSHironobu Sasano
Hironobu Sasano
TITakanori Ishida
Takanori Ishida
IKIshida Kazuyuki
Ishida Kazuyuki
MMMinoru みやした Miyashita
Minoru みやした Miyashita
NONoriaki Ohuchi
Noriaki Ohuchi
Breast ultrasonography has gained widespread acceptance as a diagnostic tool for the evaluation of human breast disorders. It is important to evaluate the correlation of ultrasonography findings with the corresponding histopathological features. We retrospectively reviewed the 154 cases of breast disorders. We evaluated the correlation the ultrasonography findings and carcinoma cells extension with their corresponding histopathological findings. In addition, we also studied the information on estimation of histological types and cancer extension used by the other modalities such as computed tomography and magnetic resonance imaging. The concordance rate for margins between ultrasonography findings and histopathological features was 91.6% (P < 0.001) and that for boundary zone was 87.0% (P < 0.001). Histopathological correlation of internal and posterior echoes demonstrated that internal low echo masses were composed of fibroblastic cells with marked collagenization in the stroma, or the cases in which carcinoma cells proliferated in a monotonous, solid and/or expanding manners. Attenuation of posterior echo was detected in the cases associated with hyperplasia of collagenized fibroblastic stroma. An increased cellularity in the mass with prominent large tumor nests and little fibrous stroma demonstrated the accentuation or no alterations of the posterior echo. The concordance rate of borders was 84.4% (P < 0.001). The correlation between estimated histological type by ultrasonography diagnosis and actual histological types was 87.0%. An overall detection rate of carcinoma extension by ultrasonography was 86.4%. In addition, an overall detection rate of carcinoma extension by ultrasonography, magnetic resonance imaging and computed tomography was 93.8%. These results demonstrated correlation between histopathological and ultrasonographic findings of the breast lesions is cardinal for quality control or improving the quality of ultrasonography.

6 May 2014 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
HAHitomi Anzai
Hitomi Anzai
JFJean-Luc Falcone
Jean-Luc Falcone
Bastien ChopardBastien Chopard
Bastien Chopard
THToshiyuki Hayase
Toshiyuki Hayase
MOMakoto Ohta
Makoto Ohta
A modern technique for the treatment of cerebral aneurysms involves insertion of a flow diverter stent. Flow stagnation, produced by the fine mesh structure of the diverter, is thought to promote blood clotting in an aneurysm. However, apart from its effect on flow reduction, the insertion of the metal device poses the risk of occlusion of a parent artery. One strategy for avoiding the risk of arterial occlusion is the use of a device with a higher porosity. To aid the development of optimal stents in the view point of flow reduction maintaining a high porosity, we used lattice Boltzmann flow simulations and simulated annealing optimization to investigate the optimal placement of stent struts. We constructed four idealized aneurysm geometries that resulted in four different inflow characteristics and employed a stent model with 36 unconnected struts corresponding to the porosity of 80%. Assuming intracranial flow, steady flow simulation with Reynolds number of 200 was applied for each aneurysm. Optimization of strut position was performed to minimize the average velocity in an aneurysm while maintaining the porosity. As the results of optimization, we obtained nonuniformed structure as optimized stent for each aneurysm geometry. And all optimized stents were characterized by denser struts in the inflow area. The variety of inflow patterns that resulted from differing aneurysm geometries led to unique strut placements for each aneurysm type.

17 December 2004 in International Journal for Numerical Methods in Fluids
Verified
Journal Article
Closed access
PDF file
THToshiyuki Hayase
Toshiyuki Hayase
KNKeisuke Nisugi
Keisuke Nisugi
ASAtsushi Shirai
Atsushi Shirai