In order to study the mechanism of seepage-induced geotechnical damage and characteristics of fine particle migration in sandy soil, a one-dimensional upward seepage test device was used and a series of upward seepage flow tests of sand were conducted. In these experiments, the permeability, fine particle migration and redistribution under different hydraulic gradients were investigated. The results show that local hydraulic gradient in the sand sample is larger than the critical hydraulic gradient calculated by the Terzaghi’s Equation. The seepage force will induce the fine soil particles to migrate along water flow direction and then cause the redistribution and reconsolidation of sand particles. Under the test condition, fine particles (< 0.075 mm) and fine sand particles (0.075–0.25 mm) dominate in the lost soil particles. Soil particles larger than 0.6 mm are hardly to lose.
Drainage conditions are supposed to have significant influence on sand liquefaction behavior. An infiltration device was utilized in cyclic triaxial tests to reproduce different drainage conditions by altering dry density of the within silt. Permeability coefficient ratio (kp) was utilized for quantifying the drainage boundary effect. Cyclic triaxial tests were conducted on saturated Fujian standard sand samples. Test results were used to evaluate the liquefaction potential by using the energy approach. It can be concluded that, if kp increases slightly bigger than zero, excess pore water pressure (EPWP) will respond more fiercely, and the dissipated energy that triggers sand liquefaction will be less. By considering kp, an energy-based database was built by taking kp into consideration and different neural network (NN) models were constructed to predict liquefaction potential by energy approaches accurately under different drainage boundary conditions. It was suggested that the neuro-fuzzy (NF)-based NN model has more satisfactory performance.
27 October 2017 in Journal of Offshore Mechanics and Arctic Engineering
Artificial frozen soils (AFS) have been used widely as temporary retaining walls in strata with soft and water-saturated soil deposits. After excavations, frozen soils thaw, and the lateral earth pressure penetrates through the soils subjected to freeze-thaw, and acts on man-made facilities. Therefore, it is important to investigate the lateral pressure (coefficient) responses of soils subjected to freeze-thaw to perform structure calculations and stability assessments of man-made facilities. A cubical testing apparatus was developed and tests were performed on susceptible soils under conditions of freezing to a stable thermal gradient and then thawing with a uniform temperature (Fnonuni-Tuni). The experimental results indicated a lack of notable anisotropy for the maximum lateral pre-consolidated pressures induced by the specimen's compaction and freeze-thaw. However, the freeze-thaw led to a decrement of lateral earth pressure coefficient K0, and K0 decrement under the horizontal Fnonuni-Tuni was greater than that under the vertical Fnonuni-Tuni. The measured K0 for normally consolidated and over-consolidated soil specimens exhibited anisotropic characteristics under the vertical Fnonuni-Tuni and horizontal Fnonuni-Tuni treatments. The anisotropies of K0 under the horizontal Fnonuni-Tuni were greater than that under the vertical Fnonuni-Tuni, and the anisotropies were more noticeable in the unloading path than that in the loading path. These observations have potential significances to the economical and practical design of permanent retaining walls in soft and water-saturated soil deposits.
Deep mining is an inevitable trend in China and the world, for which the construction of deep and large vertical shafts is the primary task. A shaft sinking headframe is a basic structure for supporting various hoisting and sinking equipment during vertical shaft construction. The design of the shaft sinking headframe is challenging due to the significant differences in the geometry and working load compared to conventional steel structures. Recently, the effect of uneven foundation settlement on the shaft sinking headframe has been of great concern when sinking shafts by the freezing sinking method or in permafrost soil areas. In this study, finite element calculations were performed to investigate the mechanical behavior of the SA-3 shaft sinking headframe under uneven foundation settlement (0.001–0.006 L) and normal working-load conditions. The results indicate that the most unfavorable condition for the stress of members is the diagonal double foundation settlement, and in the view of the geometric offset, the most unfavorable condition is the same-side double foundation settlement. The corner members near the settled foundation were changed from a state of compression to tension. Uneven foundation settlement of less than 0.001 L is acceptable for the safety and service performance of the shaft sinking headframe. These criteria can be used for reference in engineering practice.
In order to further reveal the pile-soil interaction mechanism during precast pile driving in saturated soft soil in coastal areas, the compaction effect and excess pore pressure response of a single pile and adjacent pile penetration under hammer driven pile construction are analyzed by using the cavity expansion and model test method. The results show that pile driving in saturated soil layer will cause large soil compaction and accumulation of excess pore water pressure. Under the model test conditions, the variation range of soil pressure and excess pore pressure is about 0.7–3.0 times and 0.5–1.5 times of soil mass weight stress. As the driving of adjacent pile, soil pressure at the constructed pile-soil interface increases gradually and fluctuates at the same time, and multi peak phenomenon appears under the influence of different soil layers. At the initial stage of driving, the pile driving force is mainly borne by the pile side friction, and the pile tip resistance will actions as the increase of penetration depth, and the relationship between them is basically linear. These results have certain guiding and reference value for the construction of precast pile driving in saturated soft soil in coastal areas.