Rok Dolenec

Dr. Rok Dolenec


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2011 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SKS. Korpar
S. Korpar
RDRok Dolenec
Rok Dolenec
PKPeter Križan
Peter Križan
RPR. Pestotnik
R. Pestotnik
ASA. Stanovnik
A. Stanovnik

30 September 2015 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
RDRok Dolenec
Rok Dolenec
SKS. Korpar
S. Korpar
PKP. Križan
P. Križan
RPR. Pestotnik
R. Pestotnik

27 September 2024 in The European Physical Journal C
Verified
Journal Article
Open access
PDF file
DRDania Consuegra Rodríguez
Dania Consuegra Rodríguez
RDRok Dolenec
Rok Dolenec
PKPeter Križan
Peter Križan
SKSamo Korpar
Samo Korpar
ASAndrej Seljak
Andrej Seljak
RPRok Pestotnik
Rok Pestotnik
Photodetectors used in future high-energy physics experiments will need to keep sufficient performance during a few years of data-taking despite radiation load, which, for example, in the planned upgrade of the Ring Imaging Cherenkov detectors in Large Hadron Collider beauty (LHCb) experiment is estimated at about 10 $$^{13}$$ 13 1-MeV neutron equivalent per cm $$^{2}$$ 2 (neq/cm $$^{2}$$ 2 ). Silicon photomultipliers (SiPMs) are considered as candidates for photodetectors for this application. However, their sensitivity to neutron irradiation may seriously compromise their operation, with the increase in dark count rates being the primary limitation after the irradiation. In this work, 1 $$\times $$ × 1 mm $$^{2}$$ 2 15 $$\mu $$ μ m pitch NUV-HD-RH silicon photomultipliers developed by the Fondazione Bruno Kessler were characterized before and after the irradiation. In total, 5 SiPMs were irradiated at the Jožef Stefan Institute TRIGA nuclear reactor with different fluences from 10 $$^{9}$$ 9 neq/cm $$^{2}$$ 2 up to 10 $$^{13}$$ 13 neq/cm $$^{2}$$ 2 . The SiPMs were also annealed at high temperatures and re-characterized after the annealing. For the SiPM characterization in all the cases, current–voltage (I-V curve) measurements, dark count rate measurements, and waveform analysis, including single photon time resolution, were carried out at different controlled temperature steps from room temperature down to the liquid nitrogen temperature. While cooling to − 20 $$^{\circ }$$ ∘ C was enough for the SiPM irradiated at 10 $$^{9}$$ 9 neq/cm $$^{2}$$ 2 to recover the ability to resolve single photons, by 10 $$^{13}$$ 13 neq/cm $$^{2}$$ 2 , cooling to liquid nitrogen temperature was necessary. With sufficient cooling, the measured single photon time resolution was around 90 ps FWHM for all irradiation levels.

6 September 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MOMatic Orehar
Matic Orehar
RDRok Dolenec
Rok Dolenec
GFGeorges El Fakhri
Georges El Fakhri
SKSamo Korpar
Samo Korpar
PKPeter Križan
Peter Križan
RPRok Pestotnik
Rok Pestotnik
In time-of-flight positron emission tomography (TOF-PET), a coincidence time resolution (CTR) below 100 ps reduces the angular coverage requirements and, thus, the geometric constraints of the scanner design. Among other possibilities, this opens the possibility of using flat-panel PET detectors. Such a design would be more cost-accessible and compact and allow for a higher degree of modularity than a conventional ring scanner. However, achieving adequate CTR is a considerable challenge and requires improvements at every level of detection. Based on recent results in the ongoing development of optimised TOF-PET photodetectors and electronics, we expect that within a few years, a CTR of about 75 ps will be be achievable at the system level. In this work, flat-panel scanners with four panels and various design parameters were simulated, assessed and compared to a reference scanner based on the Siemens Biograph Vision using NEMA NU 2-2018 metrics. Point sources were also simulated, and a method for evaluating spatial resolution that is more appropriate for flat-panel geometry is presented. We also studied the effects of crystal readout strategies, comparing single-crystal and module readout levels. The results demonstrate that with a CTR below 100 ps, a flat-panel scanner can achieve image quality comparable to that of a reference clinical scanner, with considerable savings in scintillator material.

8 August 2018 in Springer Proceedings in Physics
Verified
Book Chapter
Closed access
PDF file
KOK. Ogawa
K. Ogawa
IAI. Adachi
I. Adachi
RDRok Dolenec
Rok Dolenec
KHK. Hataya
K. Hataya
HKH. Kakuno
H. Kakuno
YYY. Yusa
Y. Yusa

8 August 2018 in Springer Proceedings in Physics
Verified
Book Chapter
Closed access
PDF file
MYM. Yonenaga
M. Yonenaga
IAI. Adachi
I. Adachi
RDRok Dolenec
Rok Dolenec
KHK. Hataya
K. Hataya
HKH. Kakuno
H. Kakuno
YYY. Yusa
Y. Yusa