6 September 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MOMatic Orehar
Matic Orehar
RDRok Dolenec
Rok Dolenec
GFGeorges El Fakhri
Georges El Fakhri
SKSamo Korpar
Samo Korpar
PKPeter Križan
Peter Križan
RPRok Pestotnik
Rok Pestotnik
In time-of-flight positron emission tomography (TOF-PET), a coincidence time resolution (CTR) below 100 ps reduces the angular coverage requirements and, thus, the geometric constraints of the scanner design. Among other possibilities, this opens the possibility of using flat-panel PET detectors. Such a design would be more cost-accessible and compact and allow for a higher degree of modularity than a conventional ring scanner. However, achieving adequate CTR is a considerable challenge and requires improvements at every level of detection. Based on recent results in the ongoing development of optimised TOF-PET photodetectors and electronics, we expect that within a few years, a CTR of about 75 ps will be be achievable at the system level. In this work, flat-panel scanners with four panels and various design parameters were simulated, assessed and compared to a reference scanner based on the Siemens Biograph Vision using NEMA NU 2-2018 metrics. Point sources were also simulated, and a method for evaluating spatial resolution that is more appropriate for flat-panel geometry is presented. We also studied the effects of crystal readout strategies, comparing single-crystal and module readout levels. The results demonstrate that with a CTR below 100 ps, a flat-panel scanner can achieve image quality comparable to that of a reference clinical scanner, with considerable savings in scintillator material.

1 April 2026 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
YNYassir Najmaoui
Yassir Najmaoui
YCYanis Chemli
Yanis Chemli
MTMaxime Toussaint
Maxime Toussaint
YPYoann Petibon
Yoann Petibon
BMBaptiste Marty
Baptiste Marty
TMThibault Marin
Thibault Marin
Image reconstruction for positron emission tomography (PET) requires an accurate model of the PET scanner geometry and degrading factors to produce high-quality and clinically meaningful images. It is typically implemented by scanner manufacturers, with proprietary software designed specifically for each scanner. This limits the ability to perform direct comparisons between scanners or to develop advanced image reconstruction algorithms. Open-source image reconstruction software can offer an alternative to manufacturer implementations, allowing more control and portability. Several existing software packages offer a wide range of features and interfaces, but there is still a need for an engine that simultaneously offers reusable code, fast implementation and convenient interfaces for interoperability and extensibility.

26 October 2024
Verified
Conference Paper
Closed access
MOMatic Orehar
Matic Orehar
RDR. Dolenec
R. Dolenec
GFG. El Fakhri
G. El Fakhri
DGD. Gascón
D. Gascón
AGA. Gola
A. Gola
RPR. Pestotnik
R. Pestotnik
Flat panel detectors for positron emission tomography carry the capability to deliver a cost accessible, compact, flexible and modular alternative to standard cylindrical scanners. The modular nature means that a scanner could be assembled by combining the detectors in any number of ways, such as using two or four panels to achieve different angular coverages or placing panels consecutively to achieve total body coverage. This new geometry also comes with significant challenges in image reconstruction. Sufficient coincidence timing resolution is required to avoid artifacts in reconstructed images due to limited angular coverage and to compensate for the reduced sensitivity. In this work, flat panel scanners were simulated using GATE software and images were reconstructed using CASToR. Over a million core hours were utilised to obtain these results, making heavy use of high-performance computing. Various phantoms and metrics were used to compare the performance of the flat panel scanners to a reference scanner based on the current state-of-the-art clinical scanner, Siemens Biograph Vision. The results demonstrate that with improved timing resolution, flat panel scanners can achieve image quality comparable to the reference scanner while using less than a third of the scintillator material or achieve long axial coverage (1.2 m) while using the same amount of material and achieving homogeneous contrast across the axial length of the scanner.

24 June 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
GRGašper Razdevšek
Gašper Razdevšek
RDRok Dolenec
Rok Dolenec
MOMatic Orehar
Matic Orehar
RPRok Pestotnik
Rok Pestotnik
GFGeorges El Fakhri
Georges El Fakhri
SMStanislaw Majewski
Stanislaw Majewski
Objective: Time-of-flight (TOF) resolution improves positron emission tomography (PET) by localizing annihilation events along the line of response, which reduces statistical noise and improves image quality. In open-geometry PET systems, improved TOF can compensate for limited angular sampling by reducing geometric distortions and reconstruction artifacts. This work quantitatively studies how TOF resolution and angular coverage together determine image quality in open-geometry PET. Approach: Using Monte Carlo simulations, we estimate the minimum angular coverage required to obtain reconstructions with minimal distortion for different TOF performance levels. An idealized PET scanner model is first used to isolate the effects of angular sampling and TOF, without detector-related blurring. Five angular coverages (60°, 90°, 120°, 150°, and 180°) and six coincidence timing resolutions (400, 200, 100, 75, 50, and 25 ps FWHM) are evaluated. Image quality is assessed using point sources, the Derenzo phantom, and the NEMA image quality phantom, reporting spatial resolution, contrast recovery, background variability, and geometric distortion quantified by ellipse fitting. Main results: The results show that TOF resolutions below approximately 100 ps are a key enabling factor for highly open PET geometries, substantially reducing limited-angle artifacts and allowing image quality to approach that of full-ring systems. The main trends are further validated using a realistic Monte Carlo model of the Siemens Biograph Vision PET/CT scanner. Significance: These results provide practical design guidance for next-generation open-geometry PET systems, showing that fast TOF performance can reduce required detector coverage while preserving image quality.

4 November 2023
Verified
Conference Paper
Closed access
TMThibault Marin
Thibault Marin
YZY. Zhuo
Y. Zhuo
MOMatic Orehar
Matic Orehar
GRG. Razdevšekc
G. Razdevšekc
RDR. Dolenec
R. Dolenec
GFGeorges El Fakhri
Georges El Fakhri
Positron emission tomography (PET) has become standard practice in many clinical applications including oncology, cardiology and neurology. Recent developments in PET scanners have pushed the limits of these applications, thanks to long axial field of view scanners which can improve system sensitivity and the use of time-of-flight (TOF) information which can improve spatial resolution. However, the cost and space requirements for total-body PET systems has created a need for flexible, low-cost yet high-sensitivity systems with large axial field of view. Additionally, currently achievable TOF resolutions (around 200 ps for current clinical scanners) limit the gains in image resolution. In this work, we present the first reconstructions for a flexible two-panel ultra-high TOF resolution PET system expected to achieve 75 ps full-width at half maximum (FWHM). The scanner relies on pixelated L(Y)SO scintillators with novel detectors with dual readout measuring depth-of-interaction (DOI) information. The performance of the new system is demonstrated on Monte-Carlo simulations of an anthropomorphological numerical phantom reconstructed using a newly developed TOF+DOI-enabled reconstruction engine. The presented reconstructions exhibit high image quality, demonstrating the promise of the proposed PET system.