Nima Seifnaraghi

Nima Seifnaraghi


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2024 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JLJiayang Li
Jiayang Li
Dai JiangDai Jiang
Dai Jiang
Yu WuYu Wu
Yu Wu
JZJiaxing Zhang
Jiaxing Zhang
NSNima Seifnaraghi
Nima Seifnaraghi
ADAndreas Demosthenous
Andreas Demosthenous
Functional lung imaging for neonates using electrical impedance tomography (EIT) requires a fast frame rate to avoid under sampling the faster respiratory rate in neonates than adults. Also, the EIT system must have low power consumption to facilitate wireless operation during kangaroo care. The application of existing EIT systems primarily designed for adults is limited by the trade-off between power consumption and speed of the impedance readout. This article presents an integrated EIT system in a 65 nm CMOS node featuring a novel ultralow-power time-to-digital impedance readout method based on dc cross-point detection. To increase the resolution of the impedance readout, a dynamic comparator with multi-phase voltage-controlled oscillator (VCO)-based least-common-multiple (LCM) coherent clock control is used, yielding a measured impedance error of 0.94% and a phase error of 0.81 $^{\circ}$ over a frequency range from 100 to 500 kHz in a 10 $\mu$ s measurement time. In addition, a novel fast-settling switch matrix allows multiplexing the single impedance readout channel, significantly decreasing power consumption without degradation in speed. The EIT system has a maximum frame rate of 355 frames per second (fps) and a total power consumption of 1.76 mW. The impedance readout and digitization consume 172 $\mu$ W, a power reduction of 83%–93% compared to prior work. The frame rate is both suitable for neonatal lung imaging and other fast EIT applications. Both in vitro and adult in vivo measurements are presented.

21 January 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
NSNima Seifnaraghi
Nima Seifnaraghi
SGSerena de Gelidi
Serena de Gelidi
SNSven Nordebo
Sven Nordebo
MKMerja Kallio
Merja Kallio
IFInez Frerichs
Inez Frerichs
Richard BayfordRichard Bayford
Richard Bayford
This paper presents a new method for selecting a patient specific forward model to compensate for anatomical variations in electrical impedance tomography (EIT) monitoring of neonates. The method uses a combination of shape sensors and absolute reconstruction. It takes advantage of a probabilistic approach which automatically selects the best estimated forward model fit from pre-stored library models. Absolute/static image reconstruction is performed as the core of the posterior probability calculations. The validity and reliability of the algorithm in detecting a suitable model in the presence of measurement noise is studied with simulated and measured data from 11 patients.

27 July 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Richard BayfordRichard Bayford
Richard Bayford
RDRui Damaso
Rui Damaso
NNNazanin Neshatvar
Nazanin Neshatvar
YIYevhen Ivanenko
Yevhen Ivanenko
TRThomas W Rademacher
Thomas W Rademacher
ADAndreas Demosthenous
Andreas Demosthenous
Abstract Objective: An imaging device to locate functionalized nanoparticles, whereby therapeutic agents are transported from the site of administration specifically to diseased tissues, remains a challenge for pharmaceutical research. Here, we show a new method based on electrical impedance tomography (EIT) to provide images of the location of gold nanoparticles (GNPs) and the excitation of GNPs with radio frequencies (RF) to change impedance permitting an estimation of their location in cell models Methods: We have created an imaging system using quantum cluster GNPs as a contrast agent, activated with RF fields to heat the functionalized GNPs, which causes a change in impedance in the surrounding region. This change is then identified with EIT. Results: Images of impedance changes of around 804% are obtained for a sample of citrate stabilized GNPs in a solution of phosphate-buffered saline. A second quantification was carried out using colorectal cancer cells incubated with culture media, and the internalization of GNPs into the colorectal cancer cells was undertaken to compare them with the EIT images. When the cells were incubated with functionalized GNPs, the change was more apparent, approximately 402%. This change was reflected in the EIT image as the cell area was more clearly identifiable from the rest of the area. Significance: EIT can be used as a new method to locate functionalized GNPs in human cells and help in the development of GNP-based drugs in humans to improve their efficacy in the future.

15 June 2022 in BMC Research Notes
Verified
Journal Article
Open access
PDF file
NSNima Seifnaraghi
Nima Seifnaraghi
SGSerena de Gelidi
Serena de Gelidi
IFInéz Frerichs
Inéz Frerichs
MKMerja Kallio
Merja Kallio
Erich SorantinErich Sorantin
Erich Sorantin
Richard BayfordRichard Bayford
Richard Bayford
Objective: This study investigates the development of the thoracic cross-section at the nipple line level during the early stages of life. Unlike the descriptive awareness regarding chest development course, there exist no quantitative references concerning shape, circumference and possible dependencies to age, gender or body weight. The proposed mathematical relations are expected to help create guidelines for more realistic modelling and potential detection of abnormalities. One potential application is lung electrical impedance tomography (EIT) monitoring where accurate chest models are crucial in both extracting reliable parameters for regional ventilation function and design of EIT belts. Despite their importance, such reference data is not readily available for the younger age range due to insufficient data amid the regulations of neonatal imaging. Results: Chest circumference shows the highest correlation to body weight following the relation $$f\left(x\right)= 18.3735 \ \mathrm{ln}\left(0.0012x+2.1010\right)$$ f x = 18.3735 ln 0.0012 x + 2.1010 where x is the body weight in grams and f(x) is the chest circumference in cm at the nipple line level. No statistically significant difference in chest circumference between genders was detected. However, the shape indicated signs of both age and gender dependencies with on average boys developing a more rectangular shape than girls from the age of 1 years and 9 months.

1 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NNNazanin Neshatvar
Nazanin Neshatvar
RDRui Damaso
Rui Damaso
NSNima Seifnaraghi
Nima Seifnaraghi
ADAndreas Demosthenous
Andreas Demosthenous
RBRichard Bayford
Richard Bayford
Nanoparticle-based drugs are rapidly evolving to treat different conditions and have considerable potential. A new system based on the combination of electrical impedance tomography (EIT) imaging and a power amplifier with a RF coil has been developed to study the effect of gold nanoparticles (AuNPs) when excited in the MHz frequency range. We show that samples including AuNPs have a temperature increase of 1–1.5 °C due to the presence of RF excitation at 13.56 MHz which provides a higher rate of change for solutions without AuNPs. They also show more than a 50% increase in conductivity in difference imaging as the result of this excitation. The change for samples without AuNPs is 40%.

28 June 2023 in IEEE Access
Verified
Journal Article
Open access
NSNima Seifnaraghi
Nima Seifnaraghi
SGS. De Gelidi
S. De Gelidi
IFI. Frerichs
I. Frerichs
MKM. Kallio
M. Kallio
Erich SorantinErich Sorantin
Erich Sorantin
Richard BayfordRichard Bayford
Richard Bayford
This paper investigates the overlooked effects of the patient recumbency positions on one of the key clinically used parameters in chest electrical impedance tomography (EIT) monitoring – the silent spaces. This parameter could impact medical decisions and interventions by indicating how well each lung is being ventilated. Yet it is largely dependent on assumptions of prior model at the reconstruction stage and the closely linked region of interest (ROI) during the final calculations. The potential effect of switching recumbency modes on silent spaces as a results of internal organ movements and consequently changes in initial assumptions, has been studied. The displacement and deformations caused by posture changes from supine to lateral recumbent were evaluated via simulations considering the simultaneous gravity-dependent movement and/or deformations of heart, mediastinum, lungs and the diaphragm. The reliability of simulations was verified against reference radiography images of an 18-month-old infant in supine and decubitus lateral positions. Inspecting a set of 10 patients from age range of 1 to 2 years old revealed improvements of up to 30% in the silent space parameters when applying posture consistent amendments as opposed to fixed model/ROI to each individual. To minimize the influence of image reconstruction technique on the results two different EIT reconstruction algorithms were implemented. The outcome emphasized the importance of including recumbency situation during chest EIT monitoring within the considered age range.