CECILIA LETE

Dr. CECILIA LETE

Electrochemistry-Corrosion Department, Institute of Physical Chemistry “Ilie Murgulescu” of the Romanian Academy, 202 Splaiul Independentei, 022328 Bucharest, Romania

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2009 in Electrochimica Acta
Verified
Journal Article
Closed access
SLStelian Lupu
Stelian Lupu
CECILIA LETECECILIA LETE
CECILIA LETE
MMMariana Marin
Mariana Marin
NTNicolae Totir
Nicolae Totir
Paul Cătălin BalaurePaul Cătălin Balaure
Paul Cătălin Balaure

1 December 2007 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
FVFEDERICA VALENTINI
FEDERICA VALENTINI
VBVanessa Biagiotti
Vanessa Biagiotti
CECILIA LETECECILIA LETE
CECILIA LETE
GPGiuseppe Palleschi
Giuseppe Palleschi
JWJoseph Wang
Joseph Wang

7 March 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
SLSorina-Alexandra Leau
Sorina-Alexandra Leau
CECILIA LETECECILIA LETE
CECILIA LETE
Stelian LupuStelian Lupu
Stelian Lupu
Neurotransmitters (NTs) are known as endogenous chemical messengers with important roles in the normal functioning of central and peripheral nervous systems. Abnormal levels of certain NTs, such as dopamine, serotonin and epinephrine, have been linked with several neurodegenerative diseases (such as Alzheimer’s disease, Parkinson’s disease and Huntington’s disease). To date, various strategies have been employed for the quantitative determination of NTs, and nanocomposite materials based on conducting polymers and metal nanoparticles constitute a cornerstone for the development of electrochemical sensors with low costs, stability, fast response rates and high selectivity and sensitivity. The preparation and analytical applications of nanocomposite materials based on metal nanoparticles in the electrochemical sensing of neurotransmitters are discussed in this paper. Recent developments in the electrochemical sensing of neurotransmitters are also discussed with emphasis on the benefits brought by metal nanoparticles in improving the sensitivity of the analytical measurements. The electrochemical synthesis methods for the in situ generation of metal nanoparticles within conducting polymer layers are reviewed. The analytical applications of the nanocomposite-sensing materials towards the detection of neurotransmitters such as dopamine, epinephrine and serotonin are discussed in terms of detection and quantification limits, linear response range, sensitivity and selectivity.

1 May 2015 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
CECILIA LETECECILIA LETE
CECILIA LETE
SLStelian Lupu
Stelian Lupu
Boris LakardBoris Lakard
Boris Lakard
JHJean-Yves Hihn
Jean-Yves Hihn
JCJavier del Campo
Javier del Campo

21 May 2013 in Sensors
Verified
Journal Article
Open access
PDF file
Stelian LupuStelian Lupu
Stelian Lupu
CECILIA LETECECILIA LETE
CECILIA LETE
Paul Cătălin BalaurePaul Cătălin Balaure
Paul Cătălin Balaure
DCDan Ion Caval
Dan Ion Caval
CMConstantin Mihailciuc
Constantin Mihailciuc
JCJavier del Campo
Javier del Campo
Bio-composite coatings consisting of poly(3,4-ethylenedioxythiophene) (PEDOT) and tyrosinase (Ty) were successfully electrodeposited on conventional size gold (Au) disk electrodes and microelectrode arrays using sinusoidal voltages. Electrochemical polymerization of the corresponding monomer was carried out in the presence of various Ty amounts in aqueous buffered solutions. The bio-composite coatings prepared using sinusoidal voltages and potentiostatic electrodeposition methods were compared in terms of morphology, electrochemical properties, and biocatalytic activity towards various analytes. The amperometric biosensors were tested in dopamine (DA) and catechol (CT) electroanalysis in aqueous buffered solutions. The analytical performance of the developed biosensors was investigated in terms of linear response range, detection limit, sensitivity, and repeatability. A semi-quantitative multi-analyte procedure for simultaneous determination of DA and CT was developed. The amperometric biosensor prepared using sinusoidal voltages showed much better analytical performance. The Au disk biosensor obtained by 50 mV alternating voltage amplitude displayed a linear response for DA concentrations ranging from 10 to 300 μM, with a detection limit of 4.18 μM.

25 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Juan García-GuzmánJuan García-Guzmán
Juan García-Guzmán
DIDavid López Iglesias
David López Iglesias
Laura M Cubillana-AguileraLaura M Cubillana-Aguilera
Laura M Cubillana-Aguilera
CECILIA LETECECILIA LETE
CECILIA LETE
Stelian LupuStelian Lupu
Stelian Lupu
DBDolores Bellido-Milla
Dolores Bellido-Milla
The application of a novel Poly(3,4-ethylenedioxythiophene)-Tyrosinase/Sonogel-Carbon electrode (PEDOT-Tyr/SNGC) biosensor to beers and wines analysis is proposed. This biosensor implies a new Sinusoidal Current (SC) electrodeposition method to immobilize the enzyme generating a nanostructure surface. The biosensors were characterized electrochemically, employing cyclic voltammetry and electrochemical impedance spectroscopy. Sensitivity, limit of detection, and correlation coefficients of the linear fitting were 2.40 × 10−4 µA·µM−1, 4.33 µM, and R2 = 0.9987, respectively. Caffeic acid is used as the reference polyphenol. A sampling of nine beers (four lager, three stout, and two non-alcoholic beers), and four wines (three red and one white wine) purchased in a local store was performed. The Polyphenol indeces for beers and wines have been assessed using the proposed biosensor, and the obtained values are in agreement with the literature data. Antioxidant properties of the samples using the 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid (ABTS) radical spectrophotometric method were also evaluated. The correlation between the polyphenol index and the antioxidant capacity was obtained for beers and wines.