Zhi-xin Gao

Dr. Zhi-xin Gao

Institute of Process Equipment, College of Energy Engineering, Zhejiang University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2017 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
Zhi-jiang JinZhi-jiang Jin
Zhi-jiang Jin
ZGZhi-xin Gao
Zhi-xin Gao
Jin-yuan QianJin-yuan Qian
Jin-yuan Qian
Zan WuZan Wu
Zan Wu
Bengt SundenBengt Sunden
Bengt Sunden
Hydrodynamic cavitation that occurs inside valves not only increases the energy consumption burden of the whole piping system but also leads to severe damages to the valve body and the piping system with a large economic loss. In this paper, in order to reduce the hydrodynamic cavitation inside globe valves, effects of valve body geometrical parameters including bending radius, deviation distance, and arc curvature linked to in/export parts on hydrodynamic cavitation are investigated by using a cavitation model. To begin with, the numerical model is compared with similar works to check its accuracy. Then, the cavitation index and the total vapor volume are predicted. The results show that vapor primarily appears around the valve seat and connecting downstream pipes. The hydrodynamic cavitation does not occur under a small inlet velocity, a large bending radius, and a large deviation distance. Cavitation intensity decreases with the increase of the bending radius, the deviation distance, and the arc curvature linked to in/export parts. This indicates that valve geometrical parameters should be chosen as large as possible, while the maximal fluid velocity should be limited. This work is of significance for hydrodynamic cavitation or globe valve design.

18 May 2018 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
Jin-yuan QianJin-yuan Qian
Jin-yuan Qian
ZGZhi-xin Gao
Zhi-xin Gao
BLBu-Zhan Liu
Bu-Zhan Liu
Zhi-jiang JinZhi-jiang Jin
Zhi-jiang Jin
Globe valve is widely used in numerous industries, and its driving energy consumption accounts for high percentages of the whole piping system. In order to figure out novel globe valves with low energy consumption, the pilot control globe valve (PCGV) is proposed, which is made up of a main valve and a pilot valve. By the pressure difference of fluid itself, the opened/closed status of the main valve can be controlled by the pilot valve, which can save driving energy and shorten the response time. In order to fit PCGV in an angle displaced piping system, the pilot control angle globe valve (PCAGV) is developed. In this paper, with validated numerical methods, both steady and transient simulations focusing on the valve core diameter, the single/multi orifices, orifice diameters and their arrangements located on the valve core bottom are presented. The results show that the pressure difference increases with the increase of the valve core diameter and the decrease of the orifice diameter, and large orifice diameters (d > 12 mm) should be avoided in case the valve cannot be opened. As for the multi orifices, it can be treated as a single orifice which having similar cross-sectional area. Meanwhile, the opening time of the main valve also increases with the increase of the valve core diameter correspondingly. Besides, a fitting formula of pressure difference calculation depending on the inlet velocity and the valve core diameter is obtained, which is a power–law relationship.

11 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JLJun-ye Li
Jun-ye Li
ZGZhi-xin Gao
Zhi-xin Gao
HWHui Wu
Hui Wu
Zhi-jiang JinZhi-jiang Jin
Zhi-jiang Jin
Cavitation inside globe valves, which is a common phenomenon if there is a high-pressure drop, is numerically investigated in this study. Firstly, the cavitation phenomenon in globe valves with a different number of cages is compared. When there is no valve cage, cavitation mainly appears at the valve seat, the bottom of the valve core, and the downstream pipelines. By installing a valve cage, cavitation bubbles can be restricted around the valve cage protecting the valve body from being damaged. Secondly, the effects of the outlet pressure, the working temperature, and the installation angle of two valve cages in a two-cage globe valve are studied to find out the best method to suppress cavitation, and cavitation number is utilized to evaluate cavitation intensity. Results show that cavitation intensity inside globe valves can be reduced by increasing the valve outlet pressure, decreasing the working temperature, or increasing the installation angle. Results suggest that increasing the outlet pressure is the most efficient way to suppress cavitation intensity in a globe valve, and the working temperature has a minimal effect on cavitation intensity.

11 January 2019 in Processes
Verified
Journal Article
Open access
PDF file
Jin-yuan QianJin-yuan Qian
Jin-yuan Qian
XLXiao-Juan Li
Xiao-Juan Li
ZGZhi-xin Gao
Zhi-xin Gao
Zhi-jiang JinZhi-jiang Jin
Zhi-jiang Jin
Liquid–liquid two-phase flow in microchannels has attracted much attention, due to the superiority of mass transfer enhancement. One of the biggest unresolved challenges is the low mixing efficiency at the microscale. Suitable mixing efficiency is important to promote the mass transfer of two-phase flow in microchannels. In this paper, the mixing efficiency in three junction configurations, including a cross-shaped junction, a cross-shaped T-junction, and a T-junction, is investigated by the volume of fluid (VOF) method coupled with user-defined scalar (UDS) model. All three junction configurations are designed with the same hydraulic diameter of 100 μm. Mixing components are distributed in the front and back parts of the droplet. The mixing efficiency in the droplet forming stage and the droplet moving stage are compared quantitatively. Results show that different junction configurations create very different mixing efficiencies, and the cross-shaped T-junction performs best, with relatively lower disperse phase fractions. However, with an increase of the disperse phase fraction, the cross-shaped junction is superior.

15 March 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
Zhi-jiang JinZhi-jiang Jin
Zhi-jiang Jin
ZGZhi-xin Gao
Zhi-xin Gao
XLXiao-Juan Li
Xiao-Juan Li
Jin-yuan QianJin-yuan Qian
Jin-yuan Qian
Microfluidic systems have witnessed rapid development in recent years. As one of the most common structures, the micro-orifice is always included inside microfluidic systems. Hydrodynamic cavitation in the micro-orifice has been experimentally discovered and is harmful to microfluidic systems. This paper investigates cavitating flow through a micro-orifice. A rectangular micro-orifice with a l/d ratio varying from 0.25 to 4 was selected and the pressure difference between the inlet and outlet varied from 50 to 300 kPa. Results show that cavitation intensity increased with an increase in pressure difference. Decreasing exit pressure led to a decrease in cavitation number and cavitation could be prevented by increasing the exit pressure. In addition, the vapor cavity also increased with an increase in pressure difference and l/d ratio. Results also show the pressure ratio at cavitation inception was 1.8 when l/d was above 0.5 and the cavitation number almost remained constant when l/d was larger than 2. Moreover, there was an apparent difference in cavitation number depending on whether l/d was larger than 1.

7 June 2017 in Journal of Fluids Engineering
Verified
Journal Article
Closed access
PDF file
Zhi-jiang JinZhi-jiang Jin
Zhi-jiang Jin
ZGZhi-xin Gao
Zhi-xin Gao
MZMing Zhang
Ming Zhang
Jin-yuan QianJin-yuan Qian
Jin-yuan Qian
Pilot-control globe valve (PCGV) can use the pressure drop caused by fluid flowing through the orifice located at valve core bottom to open or close the main valve using a small pilot valve. In this paper, computational fluid dynamics (CFD) method is adopted to analyze the pressure drop before and after valve core of PCGV and minor loss of orifice under different structural parameters and inlet velocities, and the simulation results show a good agreement with the experimental results. It turns out that the valve diameters, orifice diameters, and pilot pipe diameters have great influences on the pressure drop and the loss coefficient. Moreover, an expression is proposed which can be used to calculate minor loss coefficient, then to estimate the pressure drop and driving force of a PCGV within limited conditions. This paper can be referenced as guidance for deciding the dimension of structural parameters and spring stiffness during design process of a PCGV.