Sharanjeet Sharanjeet-Kaur

Prof. Sharanjeet Sharanjeet-Kaur

Universiti Kebangsaan Malaysia (UKM)
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Journal of Optometry
Verified
Journal Article
Open access
SSSharanjeet Sharanjeet-Kaur
Sharanjeet Sharanjeet-Kaur
CHChien Yee Ho
Chien Yee Ho
HMHaliza Abdul Mutalib
Haliza Abdul Mutalib
AGAhmad Rohi Ghazali
Ahmad Rohi Ghazali
To investigate the relationship between tear ferning patterns (TFP) and non-invasive tear break-up time (NIBUT) in normal Asian subjects. One hundred and forty-five adults with no ocular surface disorders were recruited. TFP and NIBUT were determined. Tears were collected using a capillary tube and allowed to air dry at room temperature for 10min. TFP was later observed using a light microscope and classified according to Rolando's classification. Measurement for NIBUT was obtained using a Tearscope with the slit lamp magnification. It was found that there is no significant difference between gender in TFP (Z=-1.77, P>.05) and NIBUT (Z=-1.475, P>.05). There is also no significant difference between Malay, Chinese, Indian, and other races in TFP, (H(3)=4.85, P>.05) and NIBUT (H(3)=2.18, P>.05). However, there is a significant difference between age groups of 20-29, 30-39, 40-49,and 50-60 years old in both TFP (H(3)=28.25, P<.01) and NIBUT (H(3)=36.50, P<.001). Spearman's correlation showed there was a significant relationship between TFP and NIBUT (r=-0.55, P<.001), age and NIBUT (r=-0.50, P<.001), age and TFP (r=0.41, P<.001), McMonnies score and NIBUT (r=-0.40, P<.001), McMonnies score and TFP (r=0.31, P<.001), as well as age and McMonnies score (r=0.52, P<.001). TFP and NIBUT was age dependent but not gender and race dependent. Older subjects had higher grade of TFP and McMonnies questionnaire score but lower NIBUT value. TFP and NIBUT can be used to assess the tear film quality.

1 October 2015 in Journal of Optometry
Verified
Journal Article
Open access
SISiti Aishah Ismail
Siti Aishah Ismail
SSSharanjeet Sharanjeet-Kaur
Sharanjeet Sharanjeet-Kaur
HMHaliza Abdul Mutalib
Haliza Abdul Mutalib
NNNor Fariza Ngah
Nor Fariza Ngah
To determine the influence of age and gender on macular sensitivity to light in healthy subjects of 4 age groups using the MP-1 microperimeter. A prospective study was carried out on 50 healthy subjects (age range: 18-60 years) divided into 4 age groups; 18-30 years, 31-40 years, 41-50 years and 51-60 years. Full-threshold microperimetry of the central 10° of retina was performed utilizing 32 points with the MP-1. Macula area was divided into four quadrants, which were superior nasal (SN), inferior nasal (IN), inferior temporal (IT) and superior temporal (ST). Total mean sensitivity at 10° for age groups 18-30 years, 31-40 years, 41-50 years and 51-60 years were 19.46 ± 0.30, 19.40 ± 0.39, 19.47 ± 0.35 and 18.73 ± 0.75 (dB), respectively. There was a significant difference in total mean retinal sensitivity at 10° and at the four quadrants with age but not for gender. The retinal sensitivity was highest in the IT quadrant and lowest in the SN quadrant for all age groups. The linear regression analysis revealed that there was a 0.019 dB, 0.016 dB, 0.022 dB, 0.029 dB and 0.029 dB per year age-related decline in mean macular sensitivity within the central 10° diameter in the SN, IN, IT and ST quadrants respectively. Among normal healthy subjects, there was a linear decline in retinal light sensitivity with increasing age with the highest reduction in the superior nasal quadrant and lowest in the inferior temporal quadrant.

AYArifah Nur Yahya
Arifah Nur Yahya
SSSharanjeet Sharanjeet-Kaur
Sharanjeet Sharanjeet-Kaur
SASaadah Mohamed Akhir
Saadah Mohamed Akhir
Uncorrected refractive error, especially myopia, in young children can cause permanent visual impairment in later life. However, data on the normative development of refractive error in this age group is limited, especially in Malaysia. The aim of this study was to determine the distribution of refractive error in a sample of infants and young children between the ages of 6 to 36 months in a prospective, cross-sectional study. Cycloplegic retinoscopy was conducted on both eyes of 151 children of mean age 18.09 ± 7.95 months. Mean spherical equivalent refractive error for the right and left eyes was +0.85 ± 0.97D and +0.86 ± 0.98D, respectively. The highest prevalence of refractive error was astigmatism (26%), followed by hyperopia (12.7%), myopia (1.3%) and anisometropia (0.7%). There was a reduction of hyperopic refractive error with increasing age. Myopia was seen to emerge at age 24 months. In conclusion, the prevalence of astigmatism and hyperopia in infants and young children was high, but that of myopia and anisometropia was low. There was a significant reduction in hyperopic refractive error towards emmetropia with increasing age. It is recommended that vision screening be conducted early to correct significant refractive error that may cause disruption to clear vision.

13 June 2022 in Saudi Journal of Ophthalmology
Verified
Journal Article
Open access
LRLina H. Raffa
Lina H. Raffa
KAKareem Allinjawi
Kareem Allinjawi
SSSharanjeet Sharanjeet-Kaur
Sharanjeet Sharanjeet-Kaur
SASaadah M. Akhir
Saadah M. Akhir
HMHaliza A. Mutalib
Haliza A. Mutalib
PURPOSE: The study aimed to establish the outcome of multifocal contact lenses (MFCL) (Multistage + 1.50D and Proclear + 3.00D) on myopia progression and axial length elongation over an 18-month period. METHODS: Thirty myopic schoolchildren (5 males and 25 females) aged between 13 and 15 years were randomly assigned to wear either single vision contact lens (SVCL), Multistage MFCL + 1.50D, or Proclear +3.00D MFCL for 1½ years using a double-masked design. Cycloplegic refraction, corneal curvature, and axial length were measured. RESULTS: Myopia progression was controlled by 38.6% and 66.6% in children wearing Multistage + 1.50D and Proclear +3.00D MFCL, respectively, in comparison to children wearing SVCL over an 18-month period. In terms of axial elongation, this study found a 31.1% and 63.2% control in axial elongation over 18 months of treatment in comparison to the SVCL group. No statistical significant difference in corneal curvature was found between initial and last visits for all the three groups (SVCL, P = 0.90; Multistage + 1.50 MFCL, P = 0.78, and Proclear + 3.00 MFCL, P = 0.05). CONCLUSION: Proclear +3.00D MFCL was revealed to cause slow development of myopia and axial elongation among myopic schoolchildren. MFCL with higher add powers could be more effective on myopia progression in comparison with moderate add powers.

1 July 2019 in Journal of Optometry
Verified
Journal Article
Open access
SSSharanjeet Sharanjeet-Kaur
Sharanjeet Sharanjeet-Kaur
SISiti-Aishah Ismail
Siti-Aishah Ismail
HMHaliza Abdul Mutalib
Haliza Abdul Mutalib
NNNor Fariza Ngah
Nor Fariza Ngah
The purpose of this study was to determine the relationship between HbA1c values and retinal sensitivity at central 10° using the MP-1 microperimeter. A prospective study was carried out on 32 healthy subjects (control group) and 60 diabetic patients. The diabetic patients were divided into 2 groups. Group 1 comprised of 30 patients without diabetic retinopathy (DR) and group 2 had 30 patients with mild non-proliferative DR. A full-threshold microperimetry of the central 10° of retina (the macula) was performed on all subjects, utilizing 32 points with the MP-1. The relationship between light sensitivity and HbA1c value was calculated using linear regression analysis. Total mean sensitivity at 10° for group 1 without DR, group 2 with mild NPDR and control group were 18.67±0.83, 17.98±1.42 and 19.45±0.34 (dB), respectively. There was a significant difference in total mean retinal sensitivity at 10° between the 3 groups (F(2,89)=18.14, p=0.001). A simple linear regression was calculated to predict HbA1c based on retinal sensitivity. A significant regression equation was found (F(1,90)=107.61, p=0.0001, with an R2 of 0.545). The linear regression analysis revealed that there was a 0.64dB decline in mean retinal sensitivity within the central 10° diameter with an increase of 1mmHg of HbA1c. Retinal sensitivity at the central 10° of the macula is affected by changes in HbA1c values.

RGRituparna Ghoshal
Rituparna Ghoshal
SSSharanjeet Sharanjeet-Kaur
Sharanjeet Sharanjeet-Kaur
NFNorliza Mohamad Fadzil
Norliza Mohamad Fadzil
HMHaliza Abdul Mutalib
Haliza Abdul Mutalib
DGDr. Somnath Ghosh
Dr. Somnath Ghosh
RARoslin Azni Abd Aziz
Roslin Azni Abd Aziz
In early and intermediate age related macular degeneration (ARMD), visual acuity alone has failed to explain the complete variation of vision. The aim of the present study was to determine correlation between different visual functions and retinal morphology in eyes with early and intermediate ARMD. In this single center cross sectional study, patients diagnosed as early or intermediate ARMD in at least one eye were recruited. Visual functions measured were best- corrected distance visual acuity (DVA), near vision acuity (NVA), reading speed (RS), and contrast sensitivity (CS). Parameters such as thickness (RT) and volume (RV) of the retina, outer retinal layer thickness (ORLT) and volume (ORLV), outer nuclear layer thickness (ONLT) and volume (ONLV), retinal pigment epithelium layer-Bruch’s membrane complex thickness (RPET) and volume (RPEV) were assessed employing semi-auto segmentation method of Spectralis optical coherence tomography (OCT). Twenty-six eyes were evaluated. DVA, CS, and RS showed significantly good correlation with RPET, ONLT, and ONLV, whereas NVA showed good correlation with ONLV and RPET. The present study concluded that RS, CS, NVA, and DVA represent the morphological alteration in early stages and should be tested in clinical settings. ONLT, ONLV, and RPET morphological parameters can be employed as important biomarkers in diagnosis of early to intermediate ARMD.