Haliza Abdul Mutalib

Dr. Haliza Abdul Mutalib

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
WZWan Mimi Diyana Wan Zaki
Wan Mimi Diyana Wan Zaki
HMHaliza Abdul Mutalib
Haliza Abdul Mutalib
Laily Azyan RamlanLaily Azyan Ramlan
Laily Azyan Ramlan
AHAini Hussain
Aini Hussain
AMAOUACHE Mustapha
AOUACHE Mustapha
Advances in computing and AI technology have promoted the development of connected health systems, indirectly influencing approaches to cataract treatment. In addition, thanks to the development of methods for cataract detection and grading using different imaging modalities, ophthalmologists can make diagnoses with significant objectivity. This paper aims to review the development and limitations of published methods for cataract detection and grading using different imaging modalities. Over the years, the proposed methods have shown significant improvement and reasonable effort towards automated cataract detection and grading systems that utilise various imaging modalities, such as optical coherence tomography (OCT), fundus, and slit-lamp images. However, more robust and fully automated cataract detection and grading systems are still needed. In addition, imaging modalities such as fundus, slit-lamps, and OCT images require medical equipment that is expensive and not portable. Therefore, the use of digital images from a smartphone as the future of cataract screening tools could be a practical and helpful solution for ophthalmologists, especially in rural areas with limited healthcare facilities.

1 October 2015 in Journal of Optometry
Verified
Journal Article
Open access
SISiti Aishah Ismail
Siti Aishah Ismail
SSSharanjeet Sharanjeet-Kaur
Sharanjeet Sharanjeet-Kaur
HMHaliza Abdul Mutalib
Haliza Abdul Mutalib
NNNor Fariza Ngah
Nor Fariza Ngah
To determine the influence of age and gender on macular sensitivity to light in healthy subjects of 4 age groups using the MP-1 microperimeter. A prospective study was carried out on 50 healthy subjects (age range: 18-60 years) divided into 4 age groups; 18-30 years, 31-40 years, 41-50 years and 51-60 years. Full-threshold microperimetry of the central 10° of retina was performed utilizing 32 points with the MP-1. Macula area was divided into four quadrants, which were superior nasal (SN), inferior nasal (IN), inferior temporal (IT) and superior temporal (ST). Total mean sensitivity at 10° for age groups 18-30 years, 31-40 years, 41-50 years and 51-60 years were 19.46 ± 0.30, 19.40 ± 0.39, 19.47 ± 0.35 and 18.73 ± 0.75 (dB), respectively. There was a significant difference in total mean retinal sensitivity at 10° and at the four quadrants with age but not for gender. The retinal sensitivity was highest in the IT quadrant and lowest in the SN quadrant for all age groups. The linear regression analysis revealed that there was a 0.019 dB, 0.016 dB, 0.022 dB, 0.029 dB and 0.029 dB per year age-related decline in mean macular sensitivity within the central 10° diameter in the SN, IN, IT and ST quadrants respectively. Among normal healthy subjects, there was a linear decline in retinal light sensitivity with increasing age with the highest reduction in the superior nasal quadrant and lowest in the inferior temporal quadrant.

14 April 2017 in Malaysian Journal of Medical Sciences
Verified
Journal Article
Closed access
SGSomnath Ghosh
Somnath Ghosh
HMHaliza Abdul Mutalib
Haliza Abdul Mutalib
SKSharanjeet Kaur
Sharanjeet Kaur
RGRituparna Ghoshal
Rituparna Ghoshal
SRShamala Retnasabapathy
Shamala Retnasabapathy
To evaluate corneal cell morphology in patients with keratoconus using an in vivo slit scanning confocal microscope. A cross-sectional study was conducted to evaluate the corneal cell morphology of 47 keratoconus patients and 32 healthy eyes without any ocular disease. New keratoconus patients with different disease severities and without any other ocular co-morbidity were recruited from the ophthalmology department of a public hospital in Malaysia from June 2013 to May 2014. Corneal cell morphology was evaluated using an in vivo slit-scanning confocal microscope. Qualitative and quantitative data were analysed using a grading scale and the Nidek Advanced Visual Information System software, respectively. The corneal cell morphology of patients with keratoconus was significantly different from that of healthy eyes except in endothelial cell density (P = 0.072). In the keratoconus group, increased level of stromal haze, alterations such as the elongation of keratocyte nuclei and clustering of cells at the anterior stroma, and dark bands in the posterior stroma were observed with increased severity of the disease. The mean anterior and posterior stromal keratocyte densities and cell areas among the different stages of keratoconus were significantly different (P < 0.001 and P = 0.044, respectively). However, the changes observed in the endothelium were not significantly different (P > 0.05) among the three stages of keratoconus. Confocal microscopy observation showed significant changes in corneal cell morphology in keratoconic cornea from normal healthy cornea. Analysis also showed significant changes in different severities of keratoconus. Understanding the corneal cell morphology changes in keratoconus may help in the long-term monitoring and management of keratoconus.

25 October 2021 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
MMMd Mustafa Md-Muziman-Syah
Md Mustafa Md-Muziman-Syah
NMNur Solehah Muzir
Nur Solehah Muzir
HMHaliza Abdul Mutalib
Haliza Abdul Mutalib
NHNoorhazayti Ab. Halim
Noorhazayti Ab. Halim
The Quality of Life Impact Refractive Correction (QIRC) questionnaire is a Rasch-validated instrument to assess the quality of life of ametropes with refractive correction. The original QIRC was validated in the United Kingdom. This study aimed to validate the Malay version of the QIRC among refractive correction wearers in Malaysia using Rasch analysis. The original 20-item QIRC was forward-backward translated into Malay in preparation for the Pilot Malay QIRC. The pilot version was pre-tested on 105 spectacle/contact lens-corrected myopes, and the results were reviewed and cross-culturally adapted to produce the Final Malay QIRC. The final version was self-administered to a new sample of 304 participants. A Rasch analysis was conducted to evaluate the items and response categories of the Pilot and the Final Malay QIRC. Test-retest reliability was also analysed on the Final Malay QIRC. Based on the pre-test findings, Rasch analysis revealed a multidimensional scale (functional scale [Items 1 to 13] and emotional scale [Items 14 to 20], which were separated in subsequent analysis), unordered response categories for the functional scale (Category 3 was collapsed into Category 2), one misfit item (Item 3 was removed) and six items required modification (Items 4, 6 to 9, and 12 were reworded and cross-culturally adapted). In the Final Malay QIRC, both the functional and emotional scales had ordered response categories, good person reliability (functional, 0.80; emotional, 0.81) and separation index (functional, 2.01; emotional, 2.06), well-targeted items (targeting precision: functional, 0.28 logits; emotional, 0.08 logits), and satisfactory fit statistics (infit and outfit mean square were less than 1.50 for all items). A noticeable differential item functioning (DIF) between genders was found in Item 18 (DIF contrast, 0.40 logits; p = 0.04). Test-retest reliability analysis demonstrated a high intraclass correlation coefficient (0.94) and Cronbach’s alpha (0.97) with a coefficient of repeatability of ±8.14 units. The Malay-translated version of the QIRC has good psychometric characteristics for assessing the quality of life of refractive correction wearers in Malaysia. This translated and cross-culturally adapted Malay QIRC is a valid and reliable instrument that can be used in routine clinical practice.

18 February 2017 in International Journal of Ophthalmology
Verified
Journal Article
Open access
SGSomnath Ghosh
Somnath Ghosh
HMHaliza Abdul Mutalib
Haliza Abdul Mutalib
SKSharanjeet Kaur
Sharanjeet Kaur
RGRituparna Ghoshal
Rituparna Ghoshal
SRShamala Retnasabapathy
Shamala Retnasabapathy
To evaluate the corneal cell morphology of new keratoconus patients wearing two different types of rigid gas-permeable (RGP) contact lenses for 1y. Thirty nine eyes of 39 new keratoconus patients were selected and randomly fitted with two types of RGP contact lenses. Group 1 had 21 eyes with regular rigid gas-permeable (RRGP) contact lens and rest 18 eyes were in group 2 with specially designed rigid gas-permeable (SRGP) contact lens. Corneal cell morphology was evaluated using a slit scanning confocal microscope at no-lens wear and after 1y of contact lens wearing. After 1y of contact lens wearing in group 1, the mean anterior and posterior stromal keratocyte density were significantly less (P=0.006 and P=0.001, respectively) compared to no-lens wear. The mean cell area of anterior and posterior stromal keratocyte were also significantly different (P=0.005 and P=0.001) from no-lens wear. The anterior and posterior stromal haze increased by 18.74% and 23.81%, respectively after 1y of contact lens wearing. Whereas in group 2, statistically significant changes were observed only in cell density & area of anterior stroma (P=0.001 and P=0.001, respectively) after 1y. While, level of anterior and posterior stromal haze increased by 16.67% and 11.11% after 1y of contact lens wearing. Polymegathism and pleomorphism also increased after 1y of contact lens wearing in both the contact lens groups. Confocal microscopy observation shows the significant alterations in corneal cell morphology of keratoconic corneas wearing contact lenses especially in group 1. The type of contact lens must be carefully selected to minimize changes in corneal cell morphology.

RGRituparna Ghoshal
Rituparna Ghoshal
SSSharanjeet Sharanjeet-Kaur
Sharanjeet Sharanjeet-Kaur
NFNorliza Mohamad Fadzil
Norliza Mohamad Fadzil
HMHaliza Abdul Mutalib
Haliza Abdul Mutalib
DGDr. Somnath Ghosh
Dr. Somnath Ghosh
RARoslin Azni Abd Aziz
Roslin Azni Abd Aziz
In early and intermediate age related macular degeneration (ARMD), visual acuity alone has failed to explain the complete variation of vision. The aim of the present study was to determine correlation between different visual functions and retinal morphology in eyes with early and intermediate ARMD. In this single center cross sectional study, patients diagnosed as early or intermediate ARMD in at least one eye were recruited. Visual functions measured were best- corrected distance visual acuity (DVA), near vision acuity (NVA), reading speed (RS), and contrast sensitivity (CS). Parameters such as thickness (RT) and volume (RV) of the retina, outer retinal layer thickness (ORLT) and volume (ORLV), outer nuclear layer thickness (ONLT) and volume (ONLV), retinal pigment epithelium layer-Bruch’s membrane complex thickness (RPET) and volume (RPEV) were assessed employing semi-auto segmentation method of Spectralis optical coherence tomography (OCT). Twenty-six eyes were evaluated. DVA, CS, and RS showed significantly good correlation with RPET, ONLT, and ONLV, whereas NVA showed good correlation with ONLV and RPET. The present study concluded that RS, CS, NVA, and DVA represent the morphological alteration in early stages and should be tested in clinical settings. ONLT, ONLV, and RPET morphological parameters can be employed as important biomarkers in diagnosis of early to intermediate ARMD.