Kirill Yu Klyshnikov

Dr. Kirill Yu Klyshnikov

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MRMaria Rezvova
Maria Rezvova
KKKirill Yu Klyshnikov
Kirill Yu Klyshnikov
AGAleksandr Gritskevich
Aleksandr Gritskevich
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
The development of a novel artificial heart valve with outstanding durability and safety has remained a challenge since the first mechanical heart valve entered the market 65 years ago. Recent progress in high-molecular compounds opened new horizons in overcoming major drawbacks of mechanical and tissue heart valves (dysfunction and failure, tissue degradation, calcification, high immunogenic potential, and high risk of thrombosis), providing new insights into the development of an ideal artificial heart valve. Polymeric heart valves can best mimic the tissue-level mechanical behavior of the native valves. This review summarizes the evolution of polymeric heart valves and the state-of-the-art approaches to their development, fabrication, and manufacturing. The review discusses the biocompatibility and durability testing of previously investigated polymeric materials and presents the most recent developments, including the first human clinical trials of LifePolymer. New promising functional polymers, nanocomposite biomaterials, and valve designs are discussed in terms of their potential application in the development of an ideal polymeric heart valve. The superiority and inferiority of nanocomposite and hybrid materials to non-modified polymers are reported. The review proposes several concepts potentially suitable to address the above-mentioned challenges arising in the R&D of polymeric heart valves from the properties, structure, and surface of polymeric materials. Additive manufacturing, nanotechnology, anisotropy control, machine learning, and advanced modeling tools have given the green light to set new directions for polymeric heart valves.

24 March 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
ASAmelia Seifalian
Amelia Seifalian
MRMaria Rezvova
Maria Rezvova
KKKirill Yu Klyshnikov
Kirill Yu Klyshnikov
TGTatiana V. Glushkova
Tatiana V. Glushkova
LBLeonid S. Barbarash
Leonid S. Barbarash
Polymeric heart valves seem to be an attractive alternative to mechanical and biological prostheses as they are more durable, due to the superior properties of novel polymers, and have the biocompatibility and hemodynamics comparable to tissue substitutes. This study reports a comprehensive assessment of a nanocomposite based on the functionalised graphene oxide and poly(carbonate-urea)urethane with the trade name “Hastalex” in comparison with GORE-TEX, a commercial polymer routinely used for cardiovascular medical devices. Experimental data have proved that GORE-TEX has a 2.5-fold (longitudinal direction) and 3.5-fold (transverse direction) lower ultimate tensile strength in comparison with Hastalex (p < 0.05). The contact angles of Hastalex surfaces (85.2 ± 1.1°) significantly (p < 0.05) are lower than those of GORE-TEX (127.1 ± 6.8°). The highest number of viable cells Ea.hy 926 is on the Hastalex surface exceeding 7.5-fold when compared with the GORE-TEX surface (p < 0.001). The platelet deformation index for GORE-TEX is 2-fold higher than that of Hastalex polymer (p < 0.05). Calcium content is greater for GORE-TEX (8.4 mg/g) in comparison with Hastalex (0.55 mg/g). The results of this study have proven that Hastalex meets the main standards required for manufacturing artificial heart valves and has superior mechanical, hemocompatibility and calcific resistance properties in comparison with GORE-TEX.

1 February 2016 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
KKKirill Yu Klyshnikov
Kirill Yu Klyshnikov
Arseniy E YuzhalinArseniy E Yuzhalin
Arseniy E Yuzhalin
GSG.V. Savrasov
G.V. Savrasov
AKAlexander Kokov
Alexander Kokov
YKY.A. Kudryavtseva
Y.A. Kudryavtseva

8 November 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
MRMaria Rezvova
Maria Rezvova
PNPavel Nikishau
Pavel Nikishau
Sergei V KostjukSergei V Kostjuk
Sergei V Kostjuk
TGTatyana Glushkova
Tatyana Glushkova
LBLeonid Barbarash
Leonid Barbarash
Superior polymers represent a promising alternative to mechanical and biological materials commonly used for manufacturing artificial heart valves. The study is aimed at assessing poly(styrene-block-isobutylene-block-styrene) (SIBS) properties and comparing them with polytetrafluoroethylene (Gore-texTM, a reference sample). Surface topography of both materials was evaluated with scanning electron microscopy and atomic force microscopy. The mechanical properties were measured under uniaxial tension. The water contact angle was estimated to evaluate hydrophilicity/hydrophobicity of the study samples. Materials’ hemocompatibility was evaluated using cell lines (Ea.hy 926), donor blood, and in vivo. SIBS possess a regular surface relief. It is hydrophobic and has lower strength as compared to Gore-texTM (3.51 MPa vs. 13.2/23.8 MPa). SIBS and Gore-texTM have similar hemocompatibility (hemolysis, adhesion, and platelet aggregation). The subcutaneous rat implantation reports that SIBS has a lower tendency towards calcification (0.39 mg/g) compared with Gore-texTM (1.29 mg/g). SIBS is a highly hemocompatible material with a promising potential for manufacturing heart valve leaflets, but its mechanical properties require further improvements. The possible options include the reinforcement with nanofillers and introductions of new chains in its structure.

22 September 2020 in Polymers
Verified
Journal Article
Open access
PDF file
MRMaria Rezvova
Maria Rezvova
Arseniy E YuzhalinArseniy E Yuzhalin
Arseniy E Yuzhalin
TGTatyana Glushkova
Tatyana Glushkova
MMMiraslau I. Makarevich
Miraslau I. Makarevich
PNPavel Nikishau
Pavel Nikishau
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
In this study, we incorporated carbon nanotubes (CNTs) into poly(styrene-block-isobutylene-block-styrene) (SIBS) to investigate the physical characteristics of the resulting nanocomposite and its cytotoxicity to endothelial cells. CNTs were dispersed in chloroform using sonication following the addition of a SIBS solution at different ratios. The resultant nanocomposite films were analyzed by X-ray microtomography, optical and scanning electron microscopy; tensile strength was examined by uniaxial tension testing; hydrophobicity was evaluated using a sessile drop technique; for cytotoxicity analysis, human umbilical vein endothelial cells were cultured on SIBS–CNTs for 3 days. We observed an uneven distribution of CNTs in the polymer matrix with sporadic bundles of interwoven nanotubes. Increasing the CNT content from 0 wt% to 8 wt% led to an increase in the tensile strength of SIBS films from 4.69 to 16.48 MPa. The engineering normal strain significantly decreased in 1 wt% SIBS–CNT films in comparison with the unmodified samples, whereas a further increase in the CNT content did not significantly affect this parameter. The incorporation of CNT into the SIBS matrix resulted in increased hydrophilicity, whereas no cytotoxicity towards endothelial cells was noted. We suggest that SIBS–CNT may become a promising material for the manufacture of implantable devices, such as cardiovascular patches or cusps of the polymer heart valve.

1 September 2014 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
KKKirill Yu Klyshnikov
Kirill Yu Klyshnikov
AVA.R. Vlad
A.R. Vlad
ISI.N. Sizova
I.N. Sizova
AKAlexander Kokov
Alexander Kokov
IZI.U. Zhuravleva
I.U. Zhuravleva