Maria Rezvova

Ms. Maria Rezvova

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
ASAmelia Seifalian
Amelia Seifalian
MRMaria Rezvova
Maria Rezvova
KKKirill Yu Klyshnikov
Kirill Yu Klyshnikov
TGTatiana V. Glushkova
Tatiana V. Glushkova
LBLeonid S. Barbarash
Leonid S. Barbarash
Polymeric heart valves seem to be an attractive alternative to mechanical and biological prostheses as they are more durable, due to the superior properties of novel polymers, and have the biocompatibility and hemodynamics comparable to tissue substitutes. This study reports a comprehensive assessment of a nanocomposite based on the functionalised graphene oxide and poly(carbonate-urea)urethane with the trade name “Hastalex” in comparison with GORE-TEX, a commercial polymer routinely used for cardiovascular medical devices. Experimental data have proved that GORE-TEX has a 2.5-fold (longitudinal direction) and 3.5-fold (transverse direction) lower ultimate tensile strength in comparison with Hastalex (p < 0.05). The contact angles of Hastalex surfaces (85.2 ± 1.1°) significantly (p < 0.05) are lower than those of GORE-TEX (127.1 ± 6.8°). The highest number of viable cells Ea.hy 926 is on the Hastalex surface exceeding 7.5-fold when compared with the GORE-TEX surface (p < 0.001). The platelet deformation index for GORE-TEX is 2-fold higher than that of Hastalex polymer (p < 0.05). Calcium content is greater for GORE-TEX (8.4 mg/g) in comparison with Hastalex (0.55 mg/g). The results of this study have proven that Hastalex meets the main standards required for manufacturing artificial heart valves and has superior mechanical, hemocompatibility and calcific resistance properties in comparison with GORE-TEX.

8 August 2021 in Polymers
Verified
Journal Article
Open access
PDF file
LALarisa Antonova
Larisa Antonova
EKEvgeniya Krivkina
Evgeniya Krivkina
VSViktoriia Sevostianova
Viktoriia Sevostianova
AMAndrey V. Mironov
Andrey V. Mironov
MRMaria Rezvova
Maria Rezvova
LBLeonid Barbarash
Leonid Barbarash
Tissue-engineered vascular graft for the reconstruction of small arteries is still an unmet clinical need, despite the fact that a number of promising prototypes have entered preclinical development. Here we test Poly(3-hydroxybutyrate-co-3-hydroxyvalerate)Poly(ε-caprolactone) 4-mm-diameter vascular grafts equipped with vascular endothelial growth factor (VEGF), basic fibroblast growth factor (bFGF) and stromal cell-derived factor 1α (SDF-1α) and surface coated with heparin and iloprost (PHBV/PCL[VEGF-bFGF-SDF]Hep/Ilo, n = 8) in a sheep carotid artery interposition model, using biostable vascular prostheses of expanded poly(tetrafluoroethylene) (ePTFE, n = 5) as a control. Primary patency of PHBV/PCL[VEGF-bFGF-SDF]Hep/Ilo grafts was 62.5% (5/8) at 24 h postimplantation and 50% (4/8) at 18 months postimplantation, while all (5/5) ePTFE conduits were occluded within the 24 h after the surgery. At 18 months postimplantation, PHBV/PCL[VEGF-bFGF-SDF]Hep/Ilo grafts were completely resorbed and replaced by the vascular tissue. Regenerated arteries displayed a hierarchical three-layer structure similar to the native blood vessels, being fully endothelialised, highly vascularised and populated by vascular smooth muscle cells and macrophages. The most (4/5, 80%) of the regenerated arteries were free of calcifications but suffered from the aneurysmatic dilation. Therefore, biodegradable PHBV/PCL[VEGF-bFGF-SDF]Hep/Ilo grafts showed better short- and long-term results than bio-stable ePTFE analogues, although these scaffolds must be reinforced for the efficient prevention of aneurysms.

8 November 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
MRMaria Rezvova
Maria Rezvova
PNPavel Nikishau
Pavel Nikishau
Sergei V KostjukSergei V Kostjuk
Sergei V Kostjuk
TGTatyana Glushkova
Tatyana Glushkova
LBLeonid Barbarash
Leonid Barbarash
Superior polymers represent a promising alternative to mechanical and biological materials commonly used for manufacturing artificial heart valves. The study is aimed at assessing poly(styrene-block-isobutylene-block-styrene) (SIBS) properties and comparing them with polytetrafluoroethylene (Gore-texTM, a reference sample). Surface topography of both materials was evaluated with scanning electron microscopy and atomic force microscopy. The mechanical properties were measured under uniaxial tension. The water contact angle was estimated to evaluate hydrophilicity/hydrophobicity of the study samples. Materials’ hemocompatibility was evaluated using cell lines (Ea.hy 926), donor blood, and in vivo. SIBS possess a regular surface relief. It is hydrophobic and has lower strength as compared to Gore-texTM (3.51 MPa vs. 13.2/23.8 MPa). SIBS and Gore-texTM have similar hemocompatibility (hemolysis, adhesion, and platelet aggregation). The subcutaneous rat implantation reports that SIBS has a lower tendency towards calcification (0.39 mg/g) compared with Gore-texTM (1.29 mg/g). SIBS is a highly hemocompatible material with a promising potential for manufacturing heart valve leaflets, but its mechanical properties require further improvements. The possible options include the reinforcement with nanofillers and introductions of new chains in its structure.

3 January 2023 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
AKAlexander Kostyunin
Alexander Kostyunin
TGTatiana V. Glushkova
Tatiana V. Glushkova
ALArseniy Lobov
Arseniy Lobov
EOEvgeny A. Ovcharenko
Evgeny A. Ovcharenko
BZBozhana R. Zainullina
Bozhana R. Zainullina
AKAnton Kutikhin
Anton Kutikhin
Background: Whereas the risk factors for structural valve degeneration (SVD) of glutaraldehyde‐treated bioprosthetic heart valves (BHVs) are well studied, those responsible for the failure of BHVs fixed with alternative next‐generation chemicals remain largely unknown. This study aimed to investigate the reasons behind the development of SVD in ethylene glycol diglycidyl ether–treated BHVs. Methods and Results: Ten ethylene glycol diglycidyl ether–treated BHVs excised because of SVD, and 5 calcified aortic valves (AVs) replaced with BHVs because of calcific AV disease were collected and their proteomic profile was deciphered. Then, BHVs and AVs were interrogated for immune cell infiltration, microbial contamination, distribution of matrix‐degrading enzymes and their tissue inhibitors, lipid deposition, and calcification. In contrast with dysfunctional AVs, failing BHVs suffered from complement‐driven neutrophil invasion, excessive proteolysis, unwanted coagulation, and lipid deposition. Neutrophil infiltration was triggered by an asymptomatic bacterial colonization of the prosthetic tissue. Neutrophil elastase, myeloblastin/proteinase 3, cathepsin G, and matrix metalloproteinases (MMPs; neutrophil‐derived MMP‐8 and plasma‐derived MMP‐9), were significantly overexpressed, while tissue inhibitors of metalloproteinases 1/2 were downregulated in the BHVs as compared with AVs, together indicative of unbalanced proteolysis in the failing BHVs. As opposed to other proteases, MMP‐9 was mostly expressed in the disorganized prosthetic extracellular matrix, suggesting plasma‐derived proteases as the primary culprit of SVD in ethylene glycol diglycidyl ether–treated BHVs. Hence, hemodynamic stress and progressive accumulation of proteases led to the extracellular matrix degeneration and dystrophic calcification, ultimately resulting in SVD. Conclusions: Neutrophil‐ and plasma‐derived proteases are responsible for the loss of BHV mechanical competence and need to be thwarted to prevent SVD.

21 May 2020 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
LALarisa Antonova
Larisa Antonova
AMAndrey V. Mironov
Andrey V. Mironov
Arseniy E YuzhalinArseniy E Yuzhalin
Arseniy E Yuzhalin
EKEvgeniya Krivkina
Evgeniya Krivkina
ASAmin R. Shabaev
Amin R. Shabaev
LBLeonid Barbarash
Leonid Barbarash
The development of novel biodegradable vascular grafts of a small diameter (<6 mm) is an unmet clinical need for patients requiring arterial replacement. Here we performed a pre-clinical study of new small-caliber biodegradable vascular grafts using a sheep model of carotid artery implantation. The 4 mm diameter vascular grafts were manufactured using a mix of polyhydroxybutyrate/valerate and polycaprolactone supplemented with growth factors VEGF, bFGF and SDF-1α (PHBV/PCL-GFmix) and additionally modified by a polymer hydrogel coating with incorporation of drugs heparin and iloprost (PHBV/PCL-GFmixHep/Ilo). Animals with carotid artery autograft implantation and those implanted with clinically used GORE-TEX® grafts were used as control groups. We observed that 24 h following surgery, animals with carotid artery autograft implantation showed 87.5% patency, while all the PHBV/PCL-GFmix and GORE-TEX® grafts displayed thrombosis. PHBV/PCL-GFmixHep/Ilo grafts demonstrated 62.5% patency 24 h following surgery and it had remained at 50% 1 year post-operation. All the PHBV/PCL grafts completely degraded less than 1 year following surgery and were replaced by de novo vasculature without evidence of calcification. On the other hand, GORE-TEX® grafts displayed substantial amounts of calcium deposits throughout graft tissues. Thus, here we report a potential clinical usefulness of PHBV/PCL grafts upon their additional modification by growth factors and drugs to promote endothelialization and reduce thrombogenicity.

1 January 2019 in Russian Journal of Applied Chemistry
Verified
Journal Article
Closed access
PDF file
MRMaria Rezvova
Maria Rezvova
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
PNP. A. Nikishev
P. A. Nikishev
SKS. V. Kostyuk
S. V. Kostyuk
TGT. V. Glushkova
T. V. Glushkova
LBL. S. Barabash
L. S. Barabash
Search for promising polymer materials as a base for cusps of leaflet heart valve prostheses is a topical problem from the viewpoint of limited durability of fixed biological material. For this...