Chemical looping combustion (CLC) is one of the most advanced technologies allowing for the reduction in CO2 emissions during the combustion of solid fuels. The modified method combines chemical looping with oxygen uncoupling (CLOU) and in situ gasification chemical looping combustion (iG-CLC). As a result, an innovative hybrid chemical looping combustion came into existence, making the above two technologies complementary. Since the complexity of the CLC is still not sufficiently recognized, the study of this process is of a practical significance. The paper describes the experiences in the modelling of complex geometry CLC equipment. The experimental facility consists of two reactors: an air reactor and a fuel reactor. The paper introduces the fuzzy logic (FL) method as an artificial intelligence (AI) approach for the prediction of SO2 and NOx (i.e., NO + NO2) emissions from coal and biomass combustion carried out in air-firing; oxyfuel; iG-CLC; and CLOU conditions. The developed model has been successfully validated on a 5 kWth research unit called the dual fluidized bed chemical looping combustion of solid fuels (DFB-CLC-SF).
The paper is focused on the idea of multi-fuel combustion in a large-scale circulating fluidized bed (CFB) boiler. The article discusses the concept of simultaneous coal and syngas combustion. A comprehensive three-dimensional computational fluid dynamics (CFD) model is developed, which allows us to describe complex phenomena that occur in the combustion chamber of the CFB boiler burning coal and syngas produced from coal sludge.
Energy efficiency is one of the most important topics nowadays. It is strictly related to energy demand, energy policy, environmental pollution, and economic issues. Energy efficiency can be increased and operating costs reduced by using waste heat from other processes. One of the possibilities is to use sorption chillers to produce chilled water and desalinated water. Low-temperature waste heat is not easy to utilize because of the low energy potential. Using adsorption chillers in low-temperature conditions allows utilizing waste heat and producing useful products in many regions of the world. The paper presents the results of an experimental study carried out on a three-bed adsorption chiller with desalination function, using silica gel and water as a working pair. The laboratory test stand included one evaporator, one condenser, and three separate tanks for water, desalinated water, and brine, respectively. The test stands scheme and description were presented. All results were obtained during several test hours with stable temperature conditions in the range of 57–85 °C for the heating water. It is found that the Coefficient of Performance (COP) increased from 0.20 to 0.58 when the heating water temperature increased from 57 to 85 °C. A similar finding is reported for Specific Cooling Power (SCP), which increased from 27 to 160 W/kg as the heating water temperature increased from 57 to 85 °C. It can be concluded that the heating water temperature strongly impacts the performance of the adsorption chiller.
This paper presents the results of numerical computations for a large-scale OFz-425 CFB (circulating fluidized bed) boiler utilizing coal and syngas. Four different operating scenarios are considered, including the reference variant, corresponding to the conventional, mono-combustion of bituminous coal, and three tests involving replacement of secondary air and part of the coal stream with syngas fed by start-up burners. Pressure, gas velocity, temperature, and carbon dioxide distribution in the combustion chamber are discussed in the paper. The results indicate that the syngas supply leads to an increase in local temperature and carbon dioxide concentrations. The proposed concept is not advisable as it may lead to frequent emergency stops of the CFB boiler.
4 November 2020 in Journal of Energy Resources Technology
The main drawback of phase change materials (PCMs) is their low thermal conductivity, which limits the possibilities of a wide range of implementations. Therefore, the researchers, as found in the literature, proposed several methods to improve the thermal conductivity of PCMs, including inserting high thermal conductivity materials in nano-, micro-, and macro-scales, as well as encapsulation of PCMs. However, these inserts impact the other properties of PCMs like latent heat, melting temperature, thermal stability, and cycling stability. Hence, this paper aims to review the available in the open literature research on the main properties of enhanced PCMs that undergo solid–liquid transition. It is found that inserting high thermal conductivity materials and encapsulation results in improved thermal conductivity of PCMs, but it decreases their latent heat. Moreover, the insertions can act as nucleating agents, and the supercooling degree can be reduced. Some of the thermal conductivity enhancers (TCEs) may prevent PCMs from leakage. However, some test results are inconsistent and some seem to be questionable. Therefore, this review indicates these discrepancies and gaps in knowledge and points out possible directions for further research.