Piotr Boruta

Mr. Piotr Boruta

AGH University of Science and Technology, Faculty of Energy and Fuels, Department of Thermal and Fluid Flow Machines
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2024 in Energies
Verified
Journal Article
Open access
PDF file
ŁMŁukasz Mika
Łukasz Mika
KSKarol Sztekler
Karol Sztekler
TBTomasz Bujok
Tomasz Bujok
Piotr BorutaPiotr Boruta
Piotr Boruta
EREwelina Radomska
Ewelina Radomska
Green hydrogen, produced by water electrolysis using renewable energy sources (RES), is an emerging technology that aligns with sustainable development goals and efforts to address climate change. In addition to energy, electrolyzers require ultrapure water to operate. Although seawater is abundant on the Earth, it must be desalinated and further purified to meet the electrolyzer’s feeding water quality requirements. This paper reviews seawater purification processes for electrolysis. Three mature and commercially available desalination technologies (reverse osmosis, multiple-effect distillation, and multi-stage flash) were examined in terms of working principles, performance parameters, produced water quality, footprint, and capital and operating expenditures. Additionally, pretreatment and post-treatment techniques were explored, and the brine management methods were investigated. The findings of this study can help guide the selection and design of water treatment systems for electrolysis.

3 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
Piotr BorutaPiotr Boruta
Piotr Boruta
TBTomasz Bujok
Tomasz Bujok
ŁMŁukasz Mika
Łukasz Mika
KSKarol Sztekler
Karol Sztekler
Adsorption refrigeration systems are promising, sustainable solutions for many cooling applications. The operating range and the performance of an adsorption cooling cycle are strongly dependent on the properties of adsorbents, adsorbates, and bed coatings. Therefore, further research and analysis may lead to improved performance of adsorption coolers. In this paper, studies on working pairs using natural refrigerants and the properties of adsorbent coatings were reviewed. The selected working pairs were then thermodynamically characterised and ranked in terms of refrigerant evaporation temperature values. This was found to be a key parameter affecting the applicability of a given adsorbent/adsorbate pair and the value of SCP (Specific Cooling Power), COP (Coefficient of Performance) parameters, which are now commonly used comparison criteria of adsorption chillers. In the analysis of the coating studies, the focus was on the effect of individual parameters on the performance of the cooling system and the effect of using coated beds compared to packed beds. It was found that a fundamental problem in comparing the performance of different cooling systems is the use of different operating conditions during the tests. Therefore, the analysis compares the performance of the systems along with the most important thermodynamic cycle parameters for the latest studies.

1 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
TBTomasz Bujok
Tomasz Bujok
Piotr BorutaPiotr Boruta
Piotr Boruta
ŁMŁukasz Mika
Łukasz Mika
KSKarol Sztekler
Karol Sztekler
In the face of increasing demands with regard to the share of renewable energy sources in the energy mix, adsorption chillers are becoming a potentially important part of the energy transition. A key component of this type of equipment is the heat exchanger in the adsorption bed, the design of which affects both heat and mass transfer. This study includes an analysis of the geometry and materials used to manufacture such heat exchangers. The geometry analysis is mainly based on the evaluation of the impact of the different dimensions of the exchanger components on heat and mass transfer in the bed. The second part of the study focuses on material-related issues where the main emphasis is on the analysis of the thermal inertia of the exchanger. The paper analyses the latest research on the design of exchangers in adsorption beds, mainly from 2015–2021. Currently, the commonly used SCP and COP coefficients and various test conditions do not provide sufficient information for comparative analysis of adsorption bed heat exchangers, so the authors propose to introduce a new index for the evaluation of heat exchangers in terms of the effect of the design parameters on the energy efficiency of an adsorption chiller.

5 August 2023 in Energies
Verified
Journal Article
Open access
PDF file
WKWojciech Kalawa
Wojciech Kalawa
KSKarol Sztekler
Karol Sztekler
Agata Mlonka-MędralaAgata Mlonka-Mędrala
Agata Mlonka-Mędrala
EREwelina Radomska
Ewelina Radomska
Wojciech NowakWojciech Nowak
Wojciech Nowak
Piotr BorutaPiotr Boruta
Piotr Boruta
Adsorption systems are alternatives to compressor cooling systems. Apart from many advantages, these systems are characterized by low COP and SCP parameters. One of the most promising options to improve the performance of adsorption chillers is the replacement of the stationary bed with a fluidized one. A fluidized bed significantly increases the heat and mass transfer within the bed, enables better contact between gas and solid phases, and results in the proper mixing of adsorbent particles. This paper presents the possibility of using fluidized beds in adsorption chillers. This paper shows the results of CFD numerical modelling of the operation of a fluidized bed for an adsorption chiller and simulations of the bed temperature profiles during the adsorption and desorption processes of sorbent in a fluidized bed. This article presents an analysis of CFD simulation results for the optimal angle of heat exchangers.

5 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
LGLucia F. Pérez Garcés
Lucia F. Pérez Garcés
KSKarol Sztekler
Karol Sztekler
LALeonardo Azevedo
Leonardo Azevedo
Piotr BorutaPiotr Boruta
Piotr Boruta
TBTomasz Bujok
Tomasz Bujok
TCTomasz Marcin Chmielniak
Tomasz Marcin Chmielniak
This study investigates the crucial role of Carbon Capture and Storage (CCS) technology in mitigating CO2 emissions from Poland’s power systems, which is essential not only for meeting climate targets but also for maintaining energy security in the country. Acknowledging natural gas as a transitional fuel, the focus is on evaluating the decarbonization potential of the natural gas combined cycle (NGCC) power plant. The NGCC with and without an amine-based carbon capture unit was modeled using IPSEpro (SimTech, version 7.0). It was found that the annual CO2 emission from 435.68 MWe (net) NGCC can be reduced from 1,365,501 tons (357.8 kgCO2/MWh) to 136,556 tons (42.9 kgCO2/MWh). On the other hand, the CCS reduced the net electric power of the NGCC from 435.68 MW to 363.47 MW and the net energy efficiency from 55.60% to 46.39%. Nonetheless, these results demonstrate the potential of using the amine-based CO2 capture technology in NGCC systems. This is especially important in the context of the decarbonization of the Polish power system.

26 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
TBTomasz Bujok
Tomasz Bujok
MSMarcin Sowa
Marcin Sowa
Piotr BorutaPiotr Boruta
Piotr Boruta
ŁMŁukasz Mika
Łukasz Mika
KSKarol Sztekler
Karol Sztekler
PCPatryk Chaja
Patryk Chaja
Solar-powered adsorption chillers are a particularly interesting alternative to energy-intensive conventional refrigeration systems. Integration of the adsorption chiller with solar collectors is a very promising concept since the increase in solar radiation coincides with the increased demand for cooling. Such a solution is very economical and environmentally friendly. It also fits in with current trends related to energy policy and sustainable development. The article presents the results of tests conducted for a two-bed adsorption chiller integrated with solar collectors. The tests were performed on selected days of the summer period (July and August) at the KEZO Research Centre PAS in Jablonna (Poland). Based on the results obtained, the performance parameters of the adsorption chiller were determined, and the problems associated with the integration of all components of the system were identified and discussed. The values of the determined Coefficient of Performance (COP) and cooling capacity for the tested adsorption chiller are, depending on the day on which the tests were conducted, from 0.531 to 0.692 and from 5.16 kW to 8.71 kW, respectively. Analysis of the test results made it possible to formulate conclusions related to the design of integrated systems of adsorption chillers with solar collectors.