Xun Yang

Dr. Xun Yang


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
DLDujuan Li
Dujuan Li
HCHuiyi Chen
Huiyi Chen
KFKai Fan
Kai Fan
VLVladimir Labunov
Vladimir Labunov
SLSerguei Lazarouk
Serguei Lazarouk
GWGaofeng Wang
Gaofeng Wang

11 November 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
XYXun Yang
Xun Yang
YFYun Fan
Yun Fan
ZWZhenhua Wu
Zhenhua Wu
CLChaoran Liu
Chaoran Liu
In this paper, we present a highly sensitive and selective detection of serum carcinoembryonic antigen (CEA) based on silicon nanowire (SiNW) array device. With the help of traditional microfabrication technology, low-cost and highly controllable SiNW array devices were fabricated. After a series of surface modification processes, SiNW array biosensors show rapid and reliable response to CEA; the detection limit of serum CEA was 10 fg/mL, the current signal is linear with the logarithm of serum CEA concentration in the range of 10 fg/mL to 100 pg/mL. In this work, SiNW array biosensors can obtain strong signal and high signal-to-noise ratio; these advantages can reduce the production cost of the SiNW-based system and promote the application of SiNWs in the field of tumor marker detection.

29 February 2024 in Physica Scripta
Verified
Journal Article
Closed access
XYXun Yang
Xun Yang
CZChilin Zheng
Chilin Zheng
JLJiahui Liu
Jiahui Liu
JYJing Yu
Jing Yu
LLLiang Long
Liang Long
CLChaoran Liu
Chaoran Liu
This paper presents a high sensitivity silicon nanowire (SiNW) array sensor for precisely quantitating humidity and pH value. Well-aligned nanowires with ordered separation have been fabricated via low-cost and highly controllable traditional top-down fabrication techniques, which are fully compatible with complementary metal oxide semiconductor (CMOS) technology. Compared to bottom-up fabrication techniques, better reproducibility and stability in these procedures are indicated by fabrication results. The packaged SiNW array devices exhibit excellent linearity and repeatability when tested for humidity. Alternatively, the SiNW arrays give a quick and accurate reflection to hydrogen ion concentration after functionalized with APTES solution. Notably, the accuracy of the sensor can reach 0.1 pH. To characterize the immunity and long-term stability of the sensor, the performance of the SiNW array sensor at different temperatures and times was investigated in detail. The test results show that the SiNW array sensor has excellent test performance in gas and liquid environments, and the design makes it more competitive than those of commercialized sensors.

28 June 2022 in Biomaterials Science
Verified
Journal Article
Open access
PDF file
KLKe Lu
Ke Lu
CLChaoran Liu
Chaoran Liu
GWGaofeng Wang
Gaofeng Wang
WYWeihuang Yang
Weihuang Yang
KFKai Fan
Kai Fan
XYXun Yang
Xun Yang
Correction for ‘A highly sensitive silicon nanowire array sensor for joint detection of tumor markers CEA and AFP’ by Ke Lu et al., Biomater. Sci., 2022, https://doi.org/10.1039/D2BM00555G.