Naudia Gray

Mrs. Naudia Gray

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
NGNaudia Gray
Naudia Gray
MHMary Halstead
Mary Halstead
NGNathalie Gonzalez
Nathalie Gonzalez
LVLiza Valentin-Blasini
Liza Valentin-Blasini
CWClifford Watson
Clifford Watson
R. Steven PappasR. Steven Pappas
R. Steven Pappas
As the technology of electronic nicotine delivery systems (ENDS), including e-cigarettes, evolves, assessing metal concentrations in liquids among brands over time becomes challenging. A method for quantification of chromium, nickel, copper, zinc, cadmium, tin, and lead in ENDS liquids using triple quadrupole inductively coupled plasma mass spectrometry was developed. The method’s limits of detection (LODs) were 0.031, 0.032, 3.15, 1.27, 0.108, 0.099, 0.066 µg/g for Cr, Ni, Cu, Zn, Cd, Sn, and Pb respectively. Liquids analyzed were from different brands and flavors of refill bottles or single-use, rechargeable, and pod devices from different years. Scanning electron microscopy with energy dispersive spectroscopy further evaluated the device components’ compositions. Refill liquids before contacting a device were below lowest reportable levels (LRL) for all metals. Copper and zinc were elevated in liquids from devices containing brass. Cadmium was <LRL in all liquids and was not observed in device components. Cr, Ni, Cu, Zn, Sn, and Pb, reported in µg/g, ranged from <LRL to 0.396, 4.04, 903, 454, 0.898, and 13.5 respectively. Elevated metal concentrations in the liquid were also elevated in aerosol from the corresponding device. The data demonstrates the impact of device design and materials on toxic metals in ENDS liquid.

23 December 2020 in Journal of Analytical Toxicology
Verified
Journal Article
Open access
PDF file
NGNaudia Gray
Naudia Gray
MHMary Halstead
Mary Halstead
LVLiza Valentin-Blasini
Liza Valentin-Blasini
CWClifford Watson
Clifford Watson
R. Steven PappasR. Steven Pappas
R. Steven Pappas
High-quality, accurate data on liquid contents and aerosol emissions from electronic nicotine delivery systems (ENDS, e.g., e-cigarettes) are crucial to address potential health concerns as these devices evolve and mature. Metals are an important class of ENDS constituents that merit attention as they have various health implications. Proper sampling, handling and aerosol trapping materials are essential to generate accurate quantitative metal data and to reduce the likelihood of inaccurate results originating from inappropriate collection vessels and materials that contribute to high background levels. Published methods that meet these criteria were applied to the analyses of chromium, nickel, copper, zinc, cadmium, tin and lead in liquid and aerosol from mint/menthol and tobacco flavors of currently popular pod-based devices from three manufacturers. Metal concentrations from pods that had not been used for generating aerosol ranged from below our lowest reportable level to 0.164 µg/g for Cr, 61.3 µg/g for Ni, 927 µg/g for Cu, 14.9 µg/g for Zn, 58.2 µg/g for Sn and 2.56 µg/g for Pb. Cadmium was included in our analyte panel and was not present above detection limits in liquid or aerosol. Aerosol metal concentrations (using a 55-mL puff) ranged from below our lowest reportable level to 29.9 ng/10 puffs for Cr, 373 ng/10 puffs for Ni, 209 ng/10 puffs for Cu, 4,580 ng/10 puffs for Zn, 127 ng/10 puffs for Sn and 463 ng/10 puffs for Pb. Our results showed some metal delivery from all the products examined and highly variable metal levels between manufacturer, brand and package.

29 September 2021 in Toxics
Verified
Journal Article
Open access
PDF file
NGNathalie Gonzalez
Nathalie Gonzalez
NGNaudia Gray
Naudia Gray
R. Steven PappasR. Steven Pappas
R. Steven Pappas
MHMary Halstead
Mary Halstead
ELErica Lewis
Erica Lewis
BBBenjamin Blount
Benjamin Blount
Research gaps exist in toxic metals characterization in e-cigarette, or vaping, products (EVPs) as these analytes typically have low concentrations and most standard aerosol trapping techniques have high metals background. An additional complication arises from differences in the EVP liquid formulations with nicotine products having polar properties and non-nicotine products often being non-polar. Differences in polar and non-polar matrices and the subsequent aerosol chemistries from various EVPs required modifications of our previously reported nicotine-based EVP aerosol method. Validation and application of the expanded method, suitable for both hydrophobic and hydrophilic aerosols, are reported here. The metals analyzed for this study were Al, Cr, Fe, Co, Ni, Cu, Cd, Sn, Ba, and Pb. The method limits of detection for the modified method ranged from 0.120 ng/10 puffs for Cd to 29.3 ng/10 puffs for Al and were higher than reported for the previous method. Results of the analyses for metals in aerosols obtained from 50 EVP products are reported. Cannabinoid based EVP aerosols were below reportable levels, except for one sample with 16.08 ng/10 puffs for Cu. Nicotine-based EVP results ranged from 6.72 ng/10 puffs for Pb to 203 ng/10 puffs for Sn. Results of the analyses for these metals showed that aerosols from only 5 of the 50 devices tested had detectable metal concentrations. Concentrations of toxic elements in the aerosols for nicotine-based EVP aerosol metal concentration ranges were consistent with previously published results of aerosol analyses from this class of devices.

1 December 2020 in Toxicology in Vitro
Verified
Journal Article
Open access
KPK. Pearce
K. Pearce
NGNaudia Gray
Naudia Gray
PGPallavi Gaur
Pallavi Gaur
JJJennifer Jeon
Jennifer Jeon
ASA. Suarez
A. Suarez
CWChrista Wright
Christa Wright
Electronic nicotine delivery systems (ENDS) are a rapidly growing global market advertised as a safer alternative to combustible cigarettes. However, comprehensive investigations of END aerosol physicochemical and toxicological properties have not been fully explored across brands to assess relative safety. In this study, we evaluated aerosols collected from three ENDS – Juul Fruit Medley (5% nicotine), Logic Power (2.4% nicotine), and Mistic (1.8% nicotine). ENDS aerosols were generated using standard machine puffing regimen and collected with a novel fluoropolymer condensation trap. Triple quadrupole-inductively coupled plasma-mass determined the presence of heavy metals in collected aerosols. The toxicological effects of ENDS aerosols on normal human bronchial epithelial cells (NHBE) were investigated using cellular viability, reactive oxygen species, oxidative stress assays, along with DNA damage assessments using the CometChip©. Results indicated the total metal concentrations within collected ENDS aerosols were higher for Mistic and Logic compared to Juul. Logic Power aerosols elicited higher reactive oxygen species levels than Mistic and Juul in NHBE after 24-hr exposure. Similar dose-dependent reductions of cellular viability and total glutathione were found for each exposure. However, Logic and Juul aerosols caused greater single stranded DNA damage compared to Mistic. Our study indicates that regardless of brand, ENDS aerosols are toxic to upper airway epithelial cells and may pose a potential respiratory hazard to occasional and frequent users.

13 January 2024 in Toxics
Verified
Journal Article
Open access
PDF file
R. Steven PappasR. Steven Pappas
R. Steven Pappas
NGNaudia Gray
Naudia Gray
MHMary Halstead
Mary Halstead
CWClifford Watson
Clifford Watson
The designs and liquid formulations of Electronic Nicotine Delivery System (ENDS) devices continue to rapidly evolve. Thus, it is important to monitor and characterize ENDS aerosols for changes in toxic constituents. Many ENDS liquid formulations now include the addition of organic acids in a 1 to 1 molar ratio with nicotine. Metal concentrations in aerosols produced by ENDS devices with different nicotine salt formulations were analyzed. Aerosols from devices containing lactic acid had higher nickel, zinc, copper, and chromium concentrations than aerosols produced by devices containing benzoic acid or levulinic acid. Our scanning electron microscope with energy dispersive X-ray analytical findings showed that the metals determined in the inductively coupled plasma-mass spectrometry analytical results were consistent with the metal compositions of the ENDS device components that were exposed to the liquids and that nickel is a major constituent in many ENDS internal components. As a result of the exposure of the nickel-containing components to the ENDS liquids, resulting aerosol nickel concentrations per puff were higher from devices that contained lactic acid in comparison to devices with benzoic or levulinic acid. The aerosol nickel concentrations in 10 puffs from ENDS-containing lactic acid were, in some cases, hundreds of times higher than cigarette mainstream smoke nickel deliveries. Thus, the design of an ENDS device in terms of both physical construction components and the liquid chemical formulations could directly impact potential exposures to toxic constituents such as metals.

1 February 2022 in Talanta
Verified
Journal Article
Closed access
ECElizabeth A. Cowan
Elizabeth A. Cowan
HTHang Tran
Hang Tran
NGNaudia Gray
Naudia Gray
JPJose J. Perez
Jose J. Perez
CWClifford Watson
Clifford Watson
LVLiza Valentín-Blasini
Liza Valentín-Blasini