Héctor Enrique Jaramillo Suárez

Prof. Héctor Enrique Jaramillo Suárez

Valle del Cauca, Colombia, Universidad Autónoma de Occidente, Santiago de Cali, Colombia
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016 in Journal of Biomechanics
Verified
Journal Article
Closed access
Héctor Enrique Jaramillo SuárezHéctor Enrique Jaramillo Suárez
Héctor Enrique Jaramillo Suárez
CPChristian M. Puttlitz
Christian M. Puttlitz
KMKirk McGilvray
Kirk McGilvray
JGJosé J. García
José J. García

1 October 2015 in Journal of Manufacturing Processes
Verified
Journal Article
Closed access
MBMario Buchely
Mario Buchely
HCHenry Colorado
Henry Colorado
Héctor Enrique Jaramillo SuárezHéctor Enrique Jaramillo Suárez
Héctor Enrique Jaramillo Suárez

5 June 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
GGGabriel Gruber
Gabriel Gruber
LNLuis Fernando Nicolini
Luis Fernando Nicolini
MRMarx Ribeiro
Marx Ribeiro
TLTanja Lerchl
Tanja Lerchl
HWHans-Joachim Wilke
Hans-Joachim Wilke
KNKati Nispel
Kati Nispel
Introduction: Numerical modeling of the intervertebral disc (IVD) is challenging due to its complex and heterogeneous structure, requiring careful selection of constitutive models and material properties. A critical aspect of such modeling is the representation of annulus fibers, which significantly impact IVD biomechanics. This study presents a comparative analysis of different methods for fiber reinforcement in the annulus fibrosus of a finite element (FE) model of the human IVD.Methods: We utilized a reconstructed L4-L5 IVD geometry to compare three fiber modeling approaches: the anisotropic Holzapfel-Gasser-Ogden (HGO) model (HGO fiber model) and two sets of structural rebar elements with linear-elastic (linear rebar model) and hyperelastic (nonlinear rebar model) material definitions, respectively. Prior to calibration, we conducted a sensitivity analysis to identify the most important model parameters to be calibrated and improve the efficiency of the calibration. Calibration was performed using a genetic algorithm and in vitro range of motion (RoM) data from a published study with eight specimens tested under four loading scenarios. For validation, intradiscal pressure (IDP) measurements from the same study were used, along with additional RoM data from a separate publication involving five specimens subjected to four different loading conditions.Results: The sensitivity analysis revealed that most parameters, except for the Poisson ratio of the annulus fibers and C01 from the nucleus, significantly affected the RoM and IDP outcomes. Upon calibration, the HGO fiber model demonstrated the highest accuracy (R2 = 0.95), followed by the linear (R2 = 0.89) and nonlinear rebar models (R2 = 0.87). During the validation phase, the HGO fiber model maintained its high accuracy (RoM R2 = 0.85; IDP R2 = 0.87), while the linear and nonlinear rebar models had lower validation scores (RoM R2 = 0.71 and 0.69; IDP R2 = 0.86 and 0.8, respectively).Discussion: The results of the study demonstrate a successful calibration process that established good agreement with experimental data. Based on our findings, the HGO fiber model appears to be a more suitable option for accurate IVD FE modeling considering its higher fidelity in simulation results and computational efficiency.

25 March 2008 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
NSN.A. de Sánchez
N.A. de Sánchez
Héctor Enrique Jaramillo SuárezHéctor Enrique Jaramillo Suárez
Héctor Enrique Jaramillo Suárez
ZVZ. Vivas
Z. Vivas
WAW. Aperador
W. Aperador
CAC. Amaya
C. Amaya
JCJ.C. Caicedo
J.C. Caicedo
CrN/ZrN (1, 8, 15, and 30) bilayers were deposited onto AISI 420 steel substrates at 250 °C and 6.6x10-3 mbar with gas ratio Ar/N2 50:3.0 as gas mixture and bias -60V were applied. AFM analysis presented different morphologies, showing that the coatings with 15 bilayers had an average grain size of 49 nm; while the 30-bilayer coating exhibited grain sizes of 99 nm. Coating thicknesses were 3 μm, approximately. The Vickers Test revealed that coatings with 8, 15, and 30 bilayers bore better impact resistance than coatings with 1 bilayer. This result is considered, bearing in mind that in many bilayers propagation of fissures is slower, because the presence of layer inter-phases leads to fissures straying in other directions. Slight corrosion specks are present, but mass loss was around 40 mg. in one bilayer, a higher value than for the coatings with 15 bilayers that was near 18 mg. Homogeneity, grain size, fracture resistance, and corrosion resistance of the coatings with 15 and 30 bilayers are suitable for mechanical applications of these types of coatings, as shown in mechanical measurements. These results indicate that for engineering applications under corrosive environments, the use of these types of bilayer coatings on AISI 420 stainless steel is highly recommended.

5 December 2018 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
Héctor Enrique Jaramillo SuárezHéctor Enrique Jaramillo Suárez
Héctor Enrique Jaramillo Suárez
NSNelly Alba de Sánchez
Nelly Alba de Sánchez
Julian AvilaJulian Avila
Julian Avila
The fatigue behaviour of SAE 5160 steel was evaluated before and after applying a shot peening process by using different Almen intensities and surface coverings (uncovered, partial coverage and total coverage). In the high-cycle fatigue tests, maximum stresses of 0.8 Sut, 0.7 Sut and 0.6 Sut were applied in the three-point bending test on an Instron 8872 servo-hydraulic machine at a frequency of 10 Hz and a constant stress ratio of Smin/ Smax = 0.2 for all tests. The fatigue tests were performed based on the ASTM E8, the specimens were classified into six groups for each stress evaluated, and each group consisted of three standardised specimens (ASTM E466). Also, yield strength, ultimate strength, hardness and microhardness were obtained. The Wilcoxon’s non-parametric test was used to statistically compare all the mechanical properties obtained from the base material with those obtained after the application of the shot peening, for the different surface coverings and Almen intensities. The results showed that the shot peening process significantly increases the fatigue strength of the material, with a 94% increase in fatigue strength of the fully coated specimens. However, no significant increase in fatigue strength was found due to a change in the Almen intensity value. A high correlation factor was found between the increase in the ultimate resistance and the increase in Almen intensity; however, for the yield stress the correlation was medium and inverse. For hardness and microhardness, the correlation factor was very low. Finally, the microhardness values revealed a 3% increase in Vickers microhardness of the shot peening specimens compared to the untreated specimens.

7 November 2018 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
Héctor Enrique Jaramillo SuárezHéctor Enrique Jaramillo Suárez
Héctor Enrique Jaramillo Suárez
Due to the importance of the intervertebral disc in the mechanical behavior of the human spine, special attention has been paid to it during the development of finite element models of the human spine. The mechanical behavior of the intervertebral disc is nonlinear, heterogeneous, and anisotropic and, due to the low permeability, is usually represented as a hyperelastic model. The intervertebral disc is composed of the nucleus pulposus, the endplates, and the annulus fibrosus. The annulus fibrosus is modeled as a hyperelastic matrix reinforced with several fiber families, and researchers have used different strain energy density functions to represent it. This paper presents a comparative study between the strain energy density functions most frequently used to represent the mechanical behavior of the annulus fibrosus: the Yeoh and Mooney-Rivlin functions. A finite element model of the annulus fibrosus of the L4-L5 segment under the action of three independent and orthogonal moments of 8 N-m was used, employing Abaqus software. A structured mesh with eight divisions along the height and the radial direction of annulus fibrosus and tetrahedron elements for the endplates were used, and an exponential energy function was employed to represent the mechanical behavior of the fibers. A total of 16 families were used; the fiber orientation varied with the radial coordinate from 25° on the outer boundary to 46° on the inner boundary, measuring it with respect to the transverse plane. The mechanical constants were taken from the reported literature. The range of motion was obtained by finite element analysis using different values of the mechanical constants and these results were compared with the reported experimental data. It was found that the Yeoh function showed a better fit to the experimental range of motion than the Mooney-Rivlin function, especially in the nonlinear region.