Finite element analysis (FEA) is increasingly applied to medicine because it could increase accuracy and rapid outcomes. However, there is a lack of the method to determine Young's modulus and Poisson's ratio for fresh femoral bone and the mathematical principle's optimization for calculating nonuniform configuration. This study aimed to investigate the surrogate model for the optimization method to determine Young's modulus and Poisson's ratio of the fresh femoral bone. Young's modulus and Poisson's ratio obtained 20 ranked pairs by the Latin hypercube sampling method. The values were calculated in the finite element for root mean square error (RMSE) and were then used for solutions by a quadratic function, radial basis function (RBF), and Kriging (KG). The lowest RMSE value was 0.1518 for the RBF method, with the young's modulus at 304.4756 and the Poisson's ratio at 0.3334. The current study identified the RBF technique to determine the properties of the femoral bone. Moreover, the RBF procedure might apply to other long bones because of the comparable nonuniform configuration.
1 September 2013 in Applied Mechanics and Materials
In HDD air flow simulation, the well known LES turbulent model requires large computing times and resources, including CPU, RAM and storage intensive which is not appropriate when using various variables. The effect of an air damper is studied by the k-e model with a reduced boundary due to the lower number of equations, computing time and computer resources. Firstly the RMS velocities of a partial model are compared between LES and k-e and then the reduced boundary models are compared with the partial model. The RMS velocity errors of the partial model compared with LES and k-e are less than 6 %. The mean RMS velocity errors compared with the reduced boundary model and the partial model are 3.93% at ID and 2.12% at MD position while the OD position increased to 26.5% because there is no effect from a return flow from the flex bracket and voice coil zone. Computing time of the reduced boundary and k-e model is reduced by 68.4%. In primary HDD air flow analysis, the k-e method together with a reduced model can be used to predict the effect of an air damper.
21 February 2018 in IOP Conference Series: Earth and Environmental Science
The damper plate effect in a hard disk drive is studied using computational fluid dynamics technique. The well known Large Eddy Simulation technique needs high resources for computing power and time. This study presents a steady k-e turbulent model which needs lower resources but can predict the flow effect. The 3.5 inch hard disk drive is modeled with a hexahedral mesh for the computational domain. First, the RMS velocities of the model without damper plate and head stack assembly compared with LES and the transient k-e method are less than 6 %. After that, the damper plate is inserted into the model and the RMS velocity is compared using 4 methods which are LES, transient k-e, steady-transient k-e and steady k-e respectively. The results of k-e are very close to each other. The RMS velocity errors compared with LES rises up to 12.35-13.20 percent in the middle diameter zone, where there is an effect from diverted flow. The steady k-e provides a good computing time with 20 min/100 iterations and can show the trend of the damper plate effect which can be used usefully in future design work for various variables.