Donatella de Silva

Dr. Donatella de Silva

Department of Structures for Engineering and Architecture, University of Naples Federico II, 80125 Naples, Italy

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2022 in Coatings
Verified
Journal Article
Open access
PDF file
Donatella de SilvaDonatella de Silva
Donatella de Silva
INIolanda Nuzzo
Iolanda Nuzzo
ENEmidio Nigro
Emidio Nigro
AOAntonio Occhiuzzi
Antonio Occhiuzzi
Intumescent coatings (ICs) are often used for protecting steel buildings during a fire when the structural, aesthetic, and architectural features of the structural members should be preserved. Indeed, ICs form a thin protective layer on the steel surface, that if exposed to fire or elevated temperatures, expands in volume with a consequent reduction in density. Hence, the protective layer captivates heat and protects the structural member from damage or elevated deformation. This reactive fire protection is designed using prescriptive tables, in which the IC thickness is chosen according to the required fire resistance, critical temperature, and section factor of the steel element. These tables are elaborated on the basis of the tests results according to the UNI EN 13381-8 standard, which is the reference for characterizing reactive systems such as ICs. For its reactive nature, this fire protection has to be applied to the structure in a controlled manner, and it is good practice to verify its correct application by measuring thickness and adhesion in situ through regulated methods. The qualification process of IC systems in Italy can be realized through a voluntary certification within the scope of a European technical assessment or by means of a national technical assessment certificate that is mandatory. All these aspects related to qualification, assessment, and design of ICs are often ignored by both designers and manufacturers, especially in Italy. Therefore, this paper describes all the approaches, introducing the main technical differences, in order to provide a sort of guideline on the use of these reactive fire protections.

15 November 2022 in Fire Safety Journal
Verified
Journal Article
Open access
Donatella de SilvaDonatella de Silva
Donatella de Silva
MAM. Andreini
M. Andreini
ABA. Bilotta
A. Bilotta
GRG. De Rosa
G. De Rosa
SMS. La Mendola
S. La Mendola
ORO. Rios
O. Rios

19 January 2023 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Open access
PDF file
Donatella de SilvaDonatella de Silva
Donatella de Silva
MGMarco Gallo
Marco Gallo
LFLaura De Falco
Laura De Falco
ENEmidio Nigro
Emidio Nigro
In recent years, due to the rapid urbanization, the fire risk in transport infrastructures is becoming more critical. These fires, typically caused by highly flammable materials, can significantly compromise the stability of the structure, as well as cause significant economic and social losses. However, in current regulations, no fire design or verification criteria are provided for bridges and the buildings prescriptions are not directly applicable due to the significant differences among the fire conditions. Therefore, starting from a deep literature review, different performance levels for bridges’ structural fire resistance were proposed. These levels were linked to the fire risk classification suggested by Kodur et al., for identifying the most vulnerable bridges to fire. This methodology was applied both to the prescriptive and performance-based approaches, using nominal and natural fire curves derived by advanced zone models of several bridge fire scenarios. To better investigate the structural fire performance of bridges, parametric analyses of a typological bridge were conducted for identifying the most critical structural systems and fire scenarios. One of the most relevant finding is that the use of performance-based approach allows to consider more realistic fire conditions, to satisfy higher performance levels with an optimization of the fire protection design. Therefore, the proposed approach can be useful both for designers and industrial category to assess the bridge performances in fire, not only according to prescriptive approach but also considering the performance-based one.

27 February 2023 in Fire
Verified
Journal Article
Open access
PDF file
Donatella de SilvaDonatella de Silva
Donatella de Silva
SSSamuele Sassi
Samuele Sassi
GRGabriella De Rosa
Gabriella De Rosa
GCGiorgio Corbella
Giorgio Corbella
ENEmidio Nigro
Emidio Nigro
The main objective of this study is to compare the results in terms of gas temperature and structural elements temperature, using different localized fire models. In particular, with reference to an open car park fire, the simplified Hasemi localized fire model was firstly used for assessing the steel temperature of a typological steel-concrete beam. In the second step, the computational fluid dynamics (CFD) models were applied, also varying the geometry of the fire source; in the first case a 3D flame was considered, in the second case a flat flame source was modelled. The latter represented one of the main research novelties of this work. All the analyses were carried out without and with the activation of a sprinkler system, simulated by varying the Heat Release Rate curve, according to the Italian national fire technical code. The main results show that there was a significant effect of the fire model, indeed the Hasemi model generally overestimated the steel element temperature. Moreover, an effect of fire source modelling was observed, with greater temperature for a 3D fire source modelling in the case of no sprinkler activation. In all the analyses, to consider the sprinkler system leaded to a beneficial effect on temperature.

29 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Donatella de SilvaDonatella de Silva
Donatella de Silva
Naveed AlamNaveed Alam
Naveed Alam
ANAli Nadjai
Ali Nadjai
ENEmidio Nigro
Emidio Nigro
FAFaris Ali
Faris Ali
Slim floor systems are very common nowadays and various types are currently being used for the construction of high-rise buildings and car parks. Concrete in slim floor beams encases the steel beam section which helps to improve their fire resistance. Despite their higher fire resistance, several fire protection materials like intumescent coatings are often used to achieve a higher fire resistance where desired. The thermal properties and behaviour of various intumescent coating materials were previously studied through experimental investigations. This paper presents finite element analyses to simulate the response of unprotected and protected slim floor beams in fire using different simulation tools. For this purpose, fire tests conducted on unprotected slim floor beams and intumescent coating materials are modelled using research and commercial software. Results from the analyses are compared and verified with the available test data. These validated models are later combined to study the behaviour of protected slim floor beams in fire. Results from the study show that the research and the commercial software replicate the behaviour of slim floor beams and protection materials with good accuracy. Due to the presence of the intumescent coating, the protected slim floor beams displayed a better fire resistance as the temperature of the steel part remained below 400 °C even after 60-min of standard heating. The protected slim floor beams continued to support the external loads even after 120 min of heating.

6 February 2024 in Journal of Structural Fire Engineering
Verified
Journal Article
Closed access
Andrea LucheriniAndrea Lucherini
Andrea Lucherini
Donatella de SilvaDonatella de Silva
Donatella de Silva
Purpose: Intumescent coatings are nowadays a dominant passive system used to protect structural materials in case of fire. Due to their reactive swelling behaviour, intumescent coatings are particularly complex materials to be modelled and predicted, which can be extremely useful especially for performance-based fire safety designs. In addition, many parameters influence their performance, and this challenges the definition and quantification of their material properties. Several approaches and models of various complexities are proposed in the literature, and they are reviewed and analysed in a critical literature review.Design/methodology/approach: Analytical, finite-difference and finite-element methods for modelling intumescent coatings are compared, followed by the definition and quantification of the main physical, thermal, and optical properties of intumescent coatings: swelled thickness, thermal conductivity and resistance, density, specific heat capacity, and emissivity/absorptivity.Findings: The study highlights the scarce consideration of key influencing factors on the material properties, and the tendency to simplify the problem into effective thermo-physical properties, such as effective thermal conductivity. As a conclusion, the literature review underlines the lack of homogenisation of modelling approaches and material properties, as well as the need for a universal modelling method that can generally simulate the performance of intumescent coatings, combine the large amount of published experimental data, and reliably produce fire-safe performance-based designs.Research limitations/implications: Due to their limited applicability, high complexity and little comparability, the presented literature review does not focus on analysing and comparing different multi-component models, constituted of many model-specific input parameters. On the contrary, the presented literature review compares various approaches, models and thermo-physical properties which primarily focusses on solving the heat transfer problem through swelling intumescent systems.Originality/value: The presented literature review analyses and discusses the various modelling approaches to describe and predict the behaviour of swelling intumescent coatings as fire protection for structural materials. Due to the vast variety of available commercial products and potential testing conditions, these data are rarely compared and combined to achieve an overall understanding on the response of intumescent coatings as fire protection measure. The study highlights the lack of information and homogenisation of various modelling approaches, and it underlines the research needs about several aspects related to the intumescent coating behaviour modelling, also providing some useful suggestions for future studies.