Naveed Alam

Dr. Naveed Alam

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2022 in Fire Safety Journal
Verified
Journal Article
Closed access
ANAli Nadjai
Ali Nadjai
Naveed AlamNaveed Alam
Naveed Alam
MCMarion Charlier
Marion Charlier
OVOlivier Vassart
Olivier Vassart
SWStephen Welch
Stephen Welch
JSJohan Sjostrom
Johan Sjostrom

29 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Donatella de SilvaDonatella de Silva
Donatella de Silva
Naveed AlamNaveed Alam
Naveed Alam
ANAli Nadjai
Ali Nadjai
ENEmidio Nigro
Emidio Nigro
FAFaris Ali
Faris Ali
Slim floor systems are very common nowadays and various types are currently being used for the construction of high-rise buildings and car parks. Concrete in slim floor beams encases the steel beam section which helps to improve their fire resistance. Despite their higher fire resistance, several fire protection materials like intumescent coatings are often used to achieve a higher fire resistance where desired. The thermal properties and behaviour of various intumescent coating materials were previously studied through experimental investigations. This paper presents finite element analyses to simulate the response of unprotected and protected slim floor beams in fire using different simulation tools. For this purpose, fire tests conducted on unprotected slim floor beams and intumescent coating materials are modelled using research and commercial software. Results from the analyses are compared and verified with the available test data. These validated models are later combined to study the behaviour of protected slim floor beams in fire. Results from the study show that the research and the commercial software replicate the behaviour of slim floor beams and protection materials with good accuracy. Due to the presence of the intumescent coating, the protected slim floor beams displayed a better fire resistance as the temperature of the steel part remained below 400 °C even after 60-min of standard heating. The protected slim floor beams continued to support the external loads even after 120 min of heating.

13 May 2022 in Journal of Structural Fire Engineering
Verified
Journal Article
Closed access
ANAli Nadjai
Ali Nadjai
Naveed AlamNaveed Alam
Naveed Alam
MCMarion Charlier
Marion Charlier
OVOlivier Vassart
Olivier Vassart
XDXu Dai
Xu Dai
JSJohan Sjostrom
Johan Sjostrom
Purpose: In the frame of the European RFCS TRAFIR project, three large compartment fire tests involving steel structure were conducted by Ulster University, aiming at understanding in which conditions a travelling fire develops, as well as how it behaves and impacts the surrounding structure.Design/methodology/approach: During the experimental programme, the path and geometry of the travelling fire was studied and temperatures, heat fluxes and spread rates were measured. Influence of the travelling fire on the structural elements was also monitored during the travelling fire tests.Findings: This paper provides details related to the influence of travelling fires on a central structural steel column.Originality/value: The experimental data are presented in terms of the gas temperatures recorded in the test compartment near the column, as well as the temperatures recorded in the steel column at different levels. Because of the large data, only fire test one results are discussed in this paper.

1 October 2021 in Journal of Building Engineering
Verified
Journal Article
Closed access
Naveed AlamNaveed Alam
Naveed Alam
ANAli Nadjai
Ali Nadjai
FHFrancois Hanus
Francois Hanus
CKCharles Kahanji
Charles Kahanji
OVOlivier Vassart
Olivier Vassart

2 June 2025 in Journal of Structural Fire Engineering
Verified
Journal Article
Closed access
RKRabinder Kumar
Rabinder Kumar
Naveed AlamNaveed Alam
Naveed Alam
ANAli Nadjai
Ali Nadjai
Purpose: Steel columns are fundamental load-bearing elements in building structures, and their performance under fire conditions is critical for ensuring overall structural safety. Failures in these key components can lead to catastrophic building collapses. This emphasises the need for an in-depth understanding of their behaviour in fire scenarios. This review provides a comprehensive analysis of experimental and numerical studies that provide a comprehensive foundation for understanding the fire performance of steel columns. Design/methodology/approach: A wide range of experimental investigations is reviewed, focusing on the structural response of steel columns under fire exposure. Key aspects such as the behaviour of restrained columns, the impacts of load ratio and slenderness on critical temperatures are examined. Additionally, numerical methodologies are systematically outlined, with a step-by-step explanation of finite element modelling (FEM) development, covering element type selection, boundary conditions and fire loading simulations. Two case studies are presented to validate the numerical models against experimental results, reinforcing the reliability of the FEM approach in predicting real-world behaviour. Findings: The review consolidates findings from experimental and numerical studies and discusses the critical parameters influencing the fire performance of steel columns. Additionally, this review highlights potential research gaps, including the need for further studies on the behaviour of steel columns under travelling fires and the influence of real fire scenarios with varying heating and cooling phases. Originality/value: This review establishes a comprehensive foundation for understanding the fire performance of steel columns. Furthermore, by identifying key research gaps, it outlines directions for future studies aimed at improving the understanding and predictive accuracy of steel structures exposed to fire.

29 October 2025 in Fire
Verified
Journal Article
Open access
PDF file
RKRabinder Kumar
Rabinder Kumar
Naveed AlamNaveed Alam
Naveed Alam
ANAli Nadjai
Ali Nadjai
This paper presents a validated computational workflow for simulating the fire-induced collapse of steel moment-resisting frames, comparing static general and dynamic explicit analysis procedures. Whereas most existing studies employ dynamic explicit analysis for collapse validation, this work evaluates the capability of the static general approach as a viable alternative. Finite element models developed with beam and shell elements capture both global instability and local failure modes. The results show that the static general procedure effectively reproduces quasi-static post-buckling behaviour and predicts the critical failure temperature within 2–3% of experimental results, similar to the dynamic explicit method. For the dynamic explicit procedure, sensitivity analyses are conducted to optimise time scaling, mesh refining, and ensure realistic physical response while maintaining computational efficiency. The study demonstrates that, along with dynamic explicit analysis, static general procedure also offers a practical and reliable alternative for simulating fire-induced structural collapse, reducing computational time by up to eighteen times for beam models and around six times for shell models, while maintaining reliable accuracy.