Background: Pyruvate kinase M2 (PKM2) is a regulator of the processes of glycolysis and oxidative phosphorylation, but the roles that it plays in endometrial cancer remain largely unknown. This study evaluated the PKM2 expression in normal endometrium, endometrial hyperplasia, and endometrial carcinoma, and its prognostic value was investigated in endometrial carcinoma patients. Methods: A hospital-based retrospective review was conducted to examine the immunohistochemical PKM2 distribution in 206 endometrium samples from biopsies or hysterectomies. The immunoreactivity of PKM2 was divided into groups of low and high scores according to the extent and intensity of staining. Results: Intense cytoplasmic staining was observed for the PKM2 protein in malignant endometrial lesions. A high PKM2 score was observed in many endometrial carcinoma samples (50.0%), but there was a low percentage in endometrial atypical hyperplasia (12.5%). High PKM2 expression was not found in the normal endometrium (0.0%) nor endometrial hyperplasia without atypia (0.0%). The PKM2 protein score was significantly higher in endometrial carcinoma samples than premalignant endometrial lesions (p < 0.001). Notably, higher PKM2 scores in cases of endometrial carcinoma correlated with poor overall survival (p = 0.006), and the hazard ratio for death was 3.40 (95% confidence interval, 1.35–8.56). Conclusions: Our results indicate that the prevalence of PKM2high tumor cells in endometrial carcinoma is significantly associated with worse prognostic factors and favors a poor prognosis. The expression of PKM2 is also a potential histopathological biomarker for use in the differential diagnosis of malignant and premalignant endometrial lesions.
During certain clinical situations, some parturients require instruments for operative vaginal delivery, and various designs of vacuum extractors may affect the fetal head. To investigate the biomechanical effects of divergent sizes of silicone rubber vacuum extractors, we employed finite element analysis in this study. First, we constructed computer models for different vacuum extractor sizes (diameters: 40 mm, 50 mm, 60 mm, and 70 mm), flat surface, hemispherical ball, and fetal head shape. A hemispherical ball was the main design for the vacuum extractor model, and the material used for the vacuum extractor was silicone rubber. Next, the settings of 1 mm vacuum extractor displacement and vacuum cap pressure of 60 cmHg were applied. The main observation markers of this study were the respective von Mises stresses on the vacuum extractor and skull by the reaction force on the fixed end. The concluded results revealed that vacuum extractors with larger diameters lead to greater reaction force, stress, and strain on fetal heads. Therefore, this study’s biomechanical analytic consequences suggest that clinicians avoid selecting larger vacuum extractors during operative instrumental delivery so that fetal heads will experience less external force, deformation, and resultant complications. It could also provide a practical reference for obstetricians for instrumental vaginal delivery with the vacuum extractor made of silicone rubber.