chih-en Kuo

Dr. chih-en Kuo

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2012 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SLSheng-Fu Liang
Sheng-Fu Liang
CKchih-en Kuo
chih-en Kuo
YHYu-Han Hu
Yu-Han Hu
YPYu-Hsiang Pan
Yu-Hsiang Pan
YWYung-Hung Wang
Yung-Hung Wang
In this paper, we propose an automatic sleep-scoring method combining multiscale entropy (MSE) and autoregressive (AR) models for single-channel EEG and to assess the performance of the method comparatively with manual scoring based on full polysomnograms. This is the first time that MSE has ever been applied to sleep scoring. All-night polysomnograms from 20 healthy individuals were scored using the Rechtschaffen and Kales rules. The developed method analyzed the EEG signals of C3-A2 for sleep staging. The results of automatic and manual scorings were compared on an epoch-by-epoch basis. A total of 8480 30-s sleep EEG epochs were measured and used for performance evaluation. The epoch-by-epoch comparison was made by classifying the EEG epochs into five states (Wake/REM/S1/S2/SWS) by the proposed method and manual scoring. The overall sensitivity and kappa coefficient of MSE alone are 76.9% and 0.65, respectively. Moreover, the overall sensitivity and kappa coefficient of our proposed method of integrating MSE, AR models, and a smoothing process can reach the sensitivity level of 88.1% and 0.81, respectively. Our results show that MSE is a useful and representative feature for sleep staging. It has high accuracy and good home-care applicability because a single EEG channel is used for sleep staging.

1 March 2012 in Journal of Neuroscience Methods
Verified
Journal Article
Closed access
SLSheng-Fu Liang
Sheng-Fu Liang
CKchih-en Kuo
chih-en Kuo
YHYu-Han Hu
Yu-Han Hu
YCYu-Shian Cheng
Yu-Shian Cheng

1 June 2015 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SLSheng-Fu Liang
Sheng-Fu Liang
CKchih-en Kuo
chih-en Kuo
YLYi-Chieh Lee
Yi-Chieh Lee
WLWen-Chieh Lin
Wen-Chieh Lin
YLYen-Chen Liu
Yen-Chen Liu
FSFu-Zen Shaw
Fu-Zen Shaw
Health care researchers have recently developed several home-based sleep monitoring systems and mobile applications that support healthy sleep by monitoring a user's sleep environment, activities, or sleep quality. This study describes the design and evaluation of an electrooculogram (EOG)-based system for an automatic sleep monitoring. Compared with polysomnogram or electroencephalogram recordings, EOG has the advantage of easy placement and can be operated by the users themselves. We also design an intelligent eye mask that is user friendly for measuring sleep stage and quality. Two user experiments were carried out to demonstrate that the proposed system produces valid measurements of sleep stage and sleep quality and has good usability and reliability while not disturbing sleep significantly. These findings suggest that our system can also be applied to long-term sleep monitoring or sleep environment control to improve the user's sleep quality and make sleep more comfortable.

21 August 2012 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
SPShing-Tai Pan
Shing-Tai Pan
CKchih-en Kuo
chih-en Kuo
JZJian-Hong Zeng
Jian-Hong Zeng
SLSheng-Fu Liang
Sheng-Fu Liang
Background: Approximately one-third of the human lifespan is spent sleeping. To diagnose sleep problems, all-night polysomnographic (PSG) recordings including electroencephalograms (EEGs), electrooculograms (EOGs) and electromyograms (EMGs), are usually acquired from the patient and scored by a well-trained expert according to Rechtschaffen & Kales (R&K) rules. Visual sleep scoring is a time-consuming and subjective process. Therefore, the development of an automatic sleep scoring method is desirable. Method: The EEG, EOG and EMG signals from twenty subjects were measured. In addition to selecting sleep characteristics based on the 1968 R&K rules, features utilized in other research were collected. Thirteen features were utilized including temporal and spectrum analyses of the EEG, EOG and EMG signals, and a total of 158 hours of sleep data were recorded. Ten subjects were used to train the Discrete Hidden Markov Model (DHMM), and the remaining ten were tested by the trained DHMM for recognition. Furthermore, the 2-fold cross validation was performed during this experiment. Results: Overall agreement between the expert and the results presented is 85.29%. With the exception of S1, the sensitivities of each stage were more than 81%. The most accurate stage was SWS (94.9%), and the least-accurately classified stage was S1 (<34%). In the majority of cases, S1 was classified as Wake (21%), S2 (33%) or REM sleep (12%), consistent with previous studies. However, the total time of S1 in the 20 all-night sleep recordings was less than 4%. Conclusion: The results of the experiments demonstrate that the proposed method significantly enhances the recognition rate when compared with prior studies.

17 November 2022 in BMC Medical Informatics and Decision Making
Verified
Journal Article
Open access
PDF file
SHShih-Tien Hsu
Shih-Tien Hsu
YSYu-Jie Su
Yu-Jie Su
CHChian-Huei Hung
Chian-Huei Hung
MCMing-Jer Chen
Ming-Jer Chen
CLChien-Hsing Lu
Chien-Hsing Lu
CKchih-en Kuo
chih-en Kuo
Background: Upon the discovery of ovarian cysts, obstetricians, gynecologists, and ultrasound examiners must address the common clinical challenge of distinguishing between benign and malignant ovarian tumors. Numerous types of ovarian tumors exist, many of which exhibit similar characteristics that increase the ambiguity in clinical diagnosis. Using deep learning technology, we aimed to develop a method that rapidly and accurately assists the different diagnosis of ovarian tumors in ultrasound images. Methods: Based on deep learning method, we used ten well-known convolutional neural network models (e.g., Alexnet, GoogleNet, and ResNet) for training of transfer learning. To ensure method stability and robustness, we repeated the random sampling of the training and validation data ten times. The mean of the ten test results was set as the final assessment data. After the training process was completed, the three models with the highest ratio of calculation accuracy to time required for classification were used for ensemble learning pertaining. Finally, the interpretation results of the ensemble classifier were used as the final results. We also applied ensemble gradient-weighted class activation mapping (Grad-CAM) technology to visualize the decision-making results of the models. Results: The highest mean accuracy, mean sensitivity, and mean specificity of ten single CNN models were 90.51 ± 4.36%, 89.77 ± 4.16%, and 92.00 ± 5.95%, respectively. The mean accuracy, mean sensitivity, and mean specificity of the ensemble classifier method were 92.15 ± 2.84%, 91.37 ± 3.60%, and 92.92 ± 4.00%, respectively. The performance of the ensemble classifier is better than that of a single classifier in three evaluation metrics. Moreover, the standard deviation is also better which means the ensemble classifier is more stable and robust. Conclusion: From the comprehensive perspective of data quantity, data diversity, robustness of validation strategy, and overall accuracy, the proposed method outperformed the methods used in previous studies. In future studies, we will continue to increase the number of authenticated images and apply our proposed method in clinical settings to increase its robustness and reliability.

23 September 2016 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CKchih-en Kuo
chih-en Kuo
YLYi-Che Liu
Yi-Che Liu
DCDa-Wei Chang
Da-Wei Chang
CYChung-Ping Young
Chung-Ping Young
FSFu-Zen Shaw
Fu-Zen Shaw
SLSheng-Fu Liang
Sheng-Fu Liang
Objective: In this study, a wearable actigraphy recording device with low sampling rate (1 Hz) for power saving and data reduction and a high accuracy wake-sleep scoring method for the assessment of sleep were developed. Methods: The developed actigraphy recorder was successfully applied to overnight recordings of 81 subjects with simultaneous polysomnography (PSG) measurements. The total length of recording reached 639.8 h. A wake-sleep scoring method based on the concept of movement density evaluation and adaptive windowing was proposed. Data from subjects with good (N = 43) and poor (N = 16) sleep efficiency (SE) in the range of 52.7-97.42% were used for testing. The Bland-Altman technique was used to evaluate the concordance of various sleep measurements between the manual PSG scoring and the proposed actigraphy method. Results: For wake-sleep staging, the average accuracy, sensitivity, specificity, and kappa coefficient of the proposed system were 92.16%, 95.02%, 71.30%, and 0.64, respectively. For the assessment of SE, the accuracy of classifying the subject with good or poor SE reached 91.53%. The mean biases of SE, sleep onset time, wake after sleep onset, and total sleep time were -0.95%, 0.74 min, 2.84 min, and -4.3 min, respectively. Conclusion: These experimental results demonstrate the robustness and reliability of our method using limited activity information to estimate wake-sleep stages during overnight recordings. Significance: The results suggest that the proposed wearable actigraphy system is practical for the in-home screening of objective sleep measurements and objective evaluation of sleep improvement after treatment.