Tereza Komárková

Dr. Tereza Komárková

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Eva ZezulováEva Zezulová
Eva Zezulová
KHKamila Hasilová
Kamila Hasilová
TKTereza Komárková
Tereza Komárková
SPStoniš Patrik
Stoniš Patrik
ŠJŠtoller Jiří
Štoller Jiří
AOAnton Ondřej
Anton Ondřej
The protective structure is designed to protect the live force against the impact of a shock wave and projectiles, it cannot be diagnosed by the destructive method which devalues the protective structure by sampling. The authors are looking for a combination of suitable non-destructive technology (NDT) methods that would be used in the future to prove the degree of damage to cement-based protective structures after an explosion. This article represents the first part of an experiment designed to verify the applicability of NDT methods, to evaluate the degree of damage of the protective structure in the field. The experiment consists of three parts. The first part is a laboratory verification of the initial material characteristics of the materials used. The first test set of structural elements is made of steel fiber-reinforced concrete. The elements are evaluated using NDT methods and for comparison by destructive laboratory methods. The second part is the impact of structures using explosion and evaluation of the condition of structures using NDT methods in the field. The last part is used to verify the results of the NDT method, which ensures the residual strength of the structure in the laboratory and try to find the relationship between changes in the results of NDT methods and the residual strength. Radiography was included in the introductory and concluding parts of the experiment to verify the results. Although this method is not suitable for using in-situ, it is the only standardized method of the NDT methods used.

30 September 2016 in Key Engineering Materials
Verified
Journal Article
Closed access
PDF file
TKTereza Komárková
Tereza Komárková
Measuring instruments used for non-destructive testing of structures thanks to advances in electronics and electrical engineering are still more frequently applied. Among the building materials with which the ability to perform quality control using non-destructive testing methods would be most welcome is indisputably steel reinforced fibre concrete (SFRC). The paper deals with the design of new methods and methodologies that enable determination of the concentration and orientation of steel fibres in steel fibre reinforced concrete. Especially the distribution of steel fibres in concrete is the quintessential aspect of this construction material. Initial results of experiments have demonstrated the applicability of the proposed methods and methodologies and the objective of the article is to introduce it to the scientific community.

20 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Eva ZezulováEva Zezulová
Eva Zezulová
KHKamila Hasilová
Kamila Hasilová
PDPetr Dvořák
Petr Dvořák
BDBranislav Dubec
Branislav Dubec
TKTereza Komárková
Tereza Komárková
JŠJiří Štoller
Jiří Štoller
Fortification structures, both military and civilian, are designed to resist a blast explosion to some extent. Their technical condition after a blast load must be assessed in a fast and reliable way to enable the users’ decision about the future use of the structure. Preferably, for the assessment of the protective structure, the non-destructive testing method should be used. To assess the suitability of ultrasound testing method for fortification structures built from steel fiber reinforced concrete, an investigation in a laboratory and in situ was conducted, together with numerical simulation and statistical evaluation. The numerical simulation of the blast load of a steel fiber reinforced concrete slab was conducted using multiphysics simulation software with the aim to verify basic parameters of the field experiment. During the field tests, several slabs were loaded by plastic explosive and changes in the structure of the slabs, before and after the blast load, were examined using the ultrasound pass-through method. After the field tests, the slabs were subjected to a destructive laboratory test to determine their residual strength. Subsequently, the data sets obtained from the measurements were tested using functional data analysis. The results from the ultrasound pulse method show that specimens after a dynamic blast load can in some cases increase the strength of their cement matrix.

1 February 2018 in Measurement Science Review
Verified
Journal Article
Open access
PDF file
TKTereza Komárková
Tereza Komárková
Pavel FialaPavel Fiala
Pavel Fiala
MSMiloslav Steinbauer
Miloslav Steinbauer
ZRZdenek Roubal
Zdenek Roubal
Steel-fiber reinforced concrete is a composite material characterized by outstanding tensile properties and resistance to the development of cracks. The concrete, however, exhibits such characteristics only on the condition that the steel fibers in the final, hardened composite have been distributed evenly. The current methods to evaluate the distribution and concentration of a fiber composite are either destructive or exhibit a limited capability of evaluating the concentration and orientation of the fibers. In this context, the paper discusses tests related to the evaluation of the density and orientation of fibers in a composite material. Compared to the approaches used to date, the proposed technique is based on the evaluation of the electrical impedance Z in the band close to the resonance of the sensor–sample configuration. Using analytically expressed equations, we can evaluate the monitored part of the composite and its density at various depths of the tested sample. The method employs test blocks of composites, utilizing the resonance of the measuring device and the measured sample set; the desired state occurs within the interval of between f=3 kHz and 400 kHz.

1 January 2018 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
TKTereza Komárková
Tereza Komárková
JLJaromír Láník
Jaromír Láník
OAOndrej Anton
Ondrej Anton
Steel fiber reinforced concretes are currently very popular, especially in the construction of industrial floors of warehouses and other halls with relatively large floor areas. However, it is important to mention that despite the rapid development of steel fiber reinforced concretes, the standards and regulations for their designing and testing have not been unified yet. This paper presents findings about the physicomechanical parameters of the steel fiber reinforced concretes manufactured by adding steel fibers into the truck mixer on the building site. The experimentally obtained results from the performed tests of tensile strength in bending according to various procedures are compared, and the suitability of the methods used is assessed according to these procedures.

16 July 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
TKTereza Komárková
Tereza Komárková
JLJ Lanik
J Lanik
LTL Topolar
L Topolar
JSJ Stoller
J Stoller
PSP Stonis
P Stonis
At present, steel fibre reinforced concrete can be classified as a composite material commonly used for load-bearing building structures. Adding steel fibers to fresh mixture improves its mechanical properties in comparison to plain concrete. The problem is, however, the production technology, which has not been standardized by regulations so far, and thus, proposals for the amount of steel fibers added to the mixture are still based on the long-term experience and performed tests. The paper describes an experiment focused on the determination and assessment of mechanical properties of steel fibre reinforced concretes with high concentrations of fibres (40 kg/m3, 80 kg/m3 and 120 kg/m3). To better understand the behavior of test specimens during the three-point bending test, the acoustic emission method was used, which is able to capture active defects. The results show that the increasing amount of fibers has the influence on values of FRk,0.5 and FRk,res,1 (e.g. for concentration 40 kg/m3 is FRk, 0.5 = 13.27 kN and for 120 kg/m3 is FRk, 0.5 = 21.18 kN).