Current cochlear implant (CI) systems provide substantial benefits for patients with severe hearing loss. However, they do not allow for 24/7 hearing, mainly due to the external parts that cannot be worn in all everyday situations. One of the key missing parts for a totally implantable CI (TICI) is the microphone, which thus far has not been implantable. The goal of the current project was to develop a concept for a packaging technology for state-of-the-art microelectromechanical systems (MEMS) microphones that record the liquid-borne sound inside the inner ear (cochlea) as a microphone signal input for a TICI. The packaging concept incorporates requirements, such as biocompatibility, long-term hermeticity, a high sensing performance and a form factor that allows sensing inside the human cochlea and full integration into the existing CI electrode array. The present paper (1) describes the sensor packaging concept and the corresponding numerical and experimental design verification process and (2) gives insight into new engineering solutions for sensor packaging. Overall, a packaging concept was developed that enables MEMS microphone technology to be used for a TICI system.
Introduction: The round window membrane (RWM) acts as a pressure-relieving membrane for incompressible cochlear fluid. The reinforcement of the RWM has been used as a surgical intervention for the treatment of superior semicircular canal dehiscence and hyperacusis. The aim of this study was to investigate how RWM reinforcement affects sound pressure variations in the cochlea. Methods: The intracochlear sound pressure (ICSP) was simultaneously measured in the scala tympani (ST) and scala vestibuli (SV) of cadaveric human temporal bones (HTBs) in response to acoustic stimulation for three RWM reinforcement materials (soft tissue, cartilage, and medical-grade silicone). Results: The ICSP in the ST was significantly increased after RWM reinforcement for frequencies below 2 kHz. Between 400 and 600 Hz, all three materials demonstrated the highest median pressure increase. The higher the RWM stiffness, the larger the pressure increase: silicone (7 dB) < soft tissue (10 dB) < cartilage (13 dB). The ICSP in the SV was less affected by reinforcement. The highest median pressure increase was 3 dB. The experimental findings can be explained with numerical models of cochlear mechanics. Discussion and conclusions: RWM reinforcement increases the sound pressure in ST at lower frequencies but only has a minor influence on the SV pressure.
(1) Background: The measurement of intracochlear sound pressure (ICSP) is relevant to obtain better understanding of the biomechanics of hearing. The goal of this work was a proof of concept of a partially implantable intracochlear acoustic receiver (ICAR) fulfilling all requirements for acute ICSP measurements in a large animal. The ICAR was designed not only to be used in chronic animal experiments but also as a microphone for totally implantable cochlear implants (TICI). (2) Methods: The ICAR concept was based on a commercial MEMS condenser microphone customized with a protective diaphragm that provided a seal and optimized geometry for accessing the cochlea. The ICAR was validated under laboratory conditions and using in-vivo experiments in sheep. (3) Results: For the first time acute ICSP measurements were successfully performed in a live specimen that is representative of the anatomy and physiology of the human. Data obtained are in agreement with published data from cadavers. The surgeons reported high levels of ease of use and satisfaction with the system design. (4) Conclusions: Our results confirm that the developed ICAR can be used to measure ICSP in acute experiments. The next generation of the ICAR will be used in chronic sheep experiments and in TICI.
Micro-Electro-Mechanical Systems (MEMS) acoustic transducers are highly sophisticated devices with high sensing performance, small size, and low power consumption. To be applied in an implantable medical device, they require a customized packaging solution with a protecting shell, usually made from titanium (Ti), to fulfill biocompatibility and hermeticity requirements. To allow acoustic sound to be transferred between the surroundings and the hermetically sealed MEMS transducer, a compliant diaphragm element needs to be integrated into the protecting enclosure. In this paper, we present a novel fabrication technology for clamped micron-thick Ti diaphragms that can be applied on arbitrary 3D substrate geometry and hence directly integrated into the packaging structure. Stiffness measurements on various diaphragm samples illustrate that the technology enables a significant reduction of residual stress in the diaphragm developed during its deposition on a polymer sacrificial material.
1 March 2018 in The Journal of the Acoustical Society of America
The goal of the present project is to develop intracochlear acoustic receivers (ICAR’s) for measurement of the sound pressure in the inner ear of human temporal bones and in acute large animal experiments. In addition, the ICAR is designed to be used as an implantable microphone for totally implantable cochlear implant (TICI) systems. The presented ICAR concept is based on a commercially available MEMS condenser microphone customized with a protective diaphragm providing sealing properties and optimized sensor head geometry for accessing the tiny fluid-filled cavities of the human inner ear. The first ICAR prototypes (PT I) have been used for numerous intracochlear sound pressure measurements in human and sheep temporal bones. The data thus obtained are in good agreement with the literature. The second ICAR prototype (PT II) was further adapted for surgical insertion in the scala tympani in acute large animal experiments. First experiments have been successfully performed and further revealed that the presented ICAR concept is a suitable receiver technology for TICI systems. Currently, the development of a fully biocompatible ICAR (PT III) is ongoing. This sensor must fulfill all important requirements of a TICI device such as high performance, low power consumption and good system integration.
Background: The brainstem auditory-evoked response (BAER) is an established electrophysiological measure of neural activity from the auditory nerve up to the brain stem. The BAER is used to diagnose abnormalities in auditory pathways and in neurophysiological human and animal research. However, normative data for BAERs in sheep, which represent an adequate large animal model for translational and basic otological research, are lacking. Objective: The aim of this study was to assess the function of the ovine auditory nervous system by determining normative values for the BAER and to compare sheep with human BAER data. Methods: In this retrospective study, BAER data for click stimuli at a range of sound pressure levels (SPLs) were analyzed. A series of 15 samples from six sheep with a mean age of 41.8 months was included. Results: The mean BAER threshold was 45.3 dB SPL. At 100 dB SPL, the mean (±standard deviation, SD) latency of wave V was 4.35 (±0.18) ms, that of wave III was 2.44 (±0.15) ms, and that of wave I was 0.88 (±0.13) ms. At 100 dB SPL, the mean interpeak latency of waves I–III was 1.56 (±0.18) ms, that of waves III–V was 1.91 (±0.16) ms, and that of waves I–V was 3.47 (±0.20) ms. The mean amplitudes at 100 dB SPL were 0.04 (±0.03) µV for wave I, 0.50 (±0.24) µV for wave III, and 0.40 (±0.25) µV for wave V. Conclusions: The normative values for sheep BAERs were reproducible and similar to those of humans. The normative BAER values further support sheep as an adequate animal model for otological research.