Sanathana Konugolu Venkata Sekar

Dr. Sanathana Konugolu Venkata Sekar

Biophotonics@Tyndall, IPIC, Tyndall National Institute, Lee Maltings, Dyke Parade, T12R5CP Cork, Ireland
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Sanathana Konugolu Venkata SekarSanathana Konugolu Venkata Sekar
Sanathana Konugolu Venkata Sekar
IBIlaria Bargigia
Ilaria Bargigia
Alberto Dalla MoraAlberto Dalla Mora
Alberto Dalla Mora
PTPaola Taroni
Paola Taroni
ARAlessandro Ruggeri
Alessandro Ruggeri
AFAndrea Farina
Andrea Farina
In recent years, diffuse optical spectroscopy (DOS) is advancing as a promising tool for noninvasive quantification of tissue constituents in pathological diagnostics.1 2. 3. – 4 Traditionally, in vivo diffuse optical measurements have been performed, at most, in the 600- to 1100-nm window.5 6. – 7 This is due to high hemoglobin absorption below 600 nm and dominant water absorption combined with lack of suitable detection technology above 1100 nm. Furthermore, studies are most often performed below 900 nm, where more conventional and cheaper detectors are available. However, recent investigations emphasize the advantage of high penetration depth and enhanced constituent specificity in the short wave infrared (SWIR) 1100- to 1700-nm range.8 9. – 10 Importantly, the lack of systematic characterization of tissue constituents in the SWIR range prevents its widespread use for in vivo applications.

8 December 2015 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Open access
Sanathana Konugolu Venkata SekarSanathana Konugolu Venkata Sekar
Sanathana Konugolu Venkata Sekar
AMAlberto Dalla Mora
Alberto Dalla Mora
IBIlaria Bargigia
Ilaria Bargigia
EMEdoardo Martinenghi
Edoardo Martinenghi
CLClaus Lindner
Claus Lindner
AFAndrea Farina
Andrea Farina
We report on the design, development, and performance assessment of a portable time-resolved system measuring absorption and scattering spectra of highly diffusive media over the 600-1350 nm range. In view of clinical use, two strategies were implemented; the first one equips the system with high responsivity in key tissue absorbing regions, whereas the second one makes the system immune to time drift. The MEDPHOT protocol was used for the performance assessment of the instrument. Finally, the system was enrolled into its first in vivo trial phase, measuring the broadband absorption and scattering spectra of human manubrium, abdomen fat tissues, and forehead for the in vivo quantification of key tissue constituents.

4 April 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
LCLorenzo Cortese
Lorenzo Cortese
GPGiuseppe Lo Presti
Giuseppe Lo Presti
MPMarco Pagliazzi
Marco Pagliazzi
DCDavide Contini
Davide Contini
AMAlberto Dalla Mora
Alberto Dalla Mora
TDTurgut Durduran
Turgut Durduran
We present the recipe and characterization for preparing liquid phantoms that are suitable for both near-infrared spectroscopy and diffuse correlation spectroscopy. The phantoms have well-defined and tunable optical and dynamic properties, and consist of a solution of water and glycerol with fat emulsion as the scattering element. The recipe takes into account the effect of bulk refractive index changes due to the addition of glycerol, which is commonly used to alter the sample viscosity.

27 October 2017 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
MPM. Pagliazzi
M. Pagliazzi
Sanathana Konugolu Venkata SekarSanathana Konugolu Venkata Sekar
Sanathana Konugolu Venkata Sekar
LCL. Colombo
L. Colombo
EME. Martinenghi
E. Martinenghi
JMJ. Minnema
J. Minnema
TDT. Durduran
T. Durduran
Diffuse correlation spectroscopy (DCS), combined with time-resolved reflectance spectroscopy (TRS) or frequency domain spectroscopy, aims at path length (i.e. depth) resolved, non-invasive and simultaneous assessment of tissue composition and blood flow. However, while TRS provides a path length resolved data, the standard DCS does not. Recently, a time domain DCS experiment showed path length resolved measurements for improved quantification with respect to classical DCS, but was limited to phantoms and small animal studies. Here, we demonstrate time domain DCS for in vivo studies on the adult forehead and the arm. We achieve path length resolved DCS by means of an actively mode-locked Ti:Sapphire laser that allows high coherence pulses, thus enabling adequate signal-to-noise ratio in relatively fast (~1 s) temporal resolution. This work paves the way to the translation of this approach to practical in vivo use.

28 February 2020 in Biomedical Optics Express
Verified
Journal Article
Open access
SMSARA MOSCA
SARA MOSCA
PLPranav Lanka
Pranav Lanka
NSNick Stone
Nick Stone
Sanathana Konugolu Venkata SekarSanathana Konugolu Venkata Sekar
Sanathana Konugolu Venkata Sekar
PMPavel Matousek
Pavel Matousek
APAntonio Pifferi
Antonio Pifferi
We present a systematic characterization of the optical properties (µa and µs’) of nine representative ex vivo porcine tissues over a broadband spectrum (650-1100 nm). We applied time-resolved diffuse optical spectroscopy measurements for recovering the optical properties of porcine tissues depicting a realistic representation of the tissue heterogeneity and morphology likely to be found in different ex vivo tissues. The results demonstrate a large spectral and inter-tissue variation of optical properties. The data can be exploited for planning or simulating ex vivo experiments with various biophotonics techniques, or even to construct artificial structures mimicking specific pathologies exploiting the wide assortment in optical properties.

28 March 2019 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
Sanathana Konugolu Venkata SekarSanathana Konugolu Venkata Sekar
Sanathana Konugolu Venkata Sekar
APAndrea Pacheco
Andrea Pacheco
PMPierluigi Martella
Pierluigi Martella
HLHaiyang Li
Haiyang Li
PLPranav Lanka
Pranav Lanka
SAStefan Andersson-Engels
Stefan Andersson-Engels
We present a tissue mimicking optical phantom recipe to create robust well tested solid phantoms. The recipe consists of black silicone pigment (absorber), silica microspheres (scatterer) and silicone rubber (SiliGlass, bulk material). The phantom recipe was characterized over a broadband spectrum (600-1100 nm) for a wide range of optical properties (absorption 0.1-1 cm−1, reduced scattering 5-25 cm−1) that are relevant to human organs. The results of linearity show a proper scaling of optical properties as well as the absence of coupling between the absorber and scatterer at different concentrations. A reproducibility of 4% among different preparations was obtained, with a similar grade of spatial homogeneity. Finally, a 3D non-scattering mock-up phantom of an infant torso made with the same recipe bulk material (SiliGlass) was presented to project the futuristic aspect of our work that is 3D printing human organs of biomedical relevance.