Representative Publications

View All Publications
27 October 2017 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
MPM. Pagliazzi
M. Pagliazzi
Sanathana Konugolu Venkata SekarSanathana Konugolu Venkata Sekar
Sanathana Konugolu Venkata Sekar
LCL. Colombo
L. Colombo
EME. Martinenghi
E. Martinenghi
JMJ. Minnema
J. Minnema
TDT. Durduran
T. Durduran
Diffuse correlation spectroscopy (DCS), combined with time-resolved reflectance spectroscopy (TRS) or frequency domain spectroscopy, aims at path length (i.e. depth) resolved, non-invasive and simultaneous assessment of tissue composition and blood flow. However, while TRS provides a path length resolved data, the standard DCS does not. Recently, a time domain DCS experiment showed path length resolved measurements for improved quantification with respect to classical DCS, but was limited to phantoms and small animal studies. Here, we demonstrate time domain DCS for in vivo studies on the adult forehead and the arm. We achieve path length resolved DCS by means of an actively mode-locked Ti:Sapphire laser that allows high coherence pulses, thus enabling adequate signal-to-noise ratio in relatively fast (~1 s) temporal resolution. This work paves the way to the translation of this approach to practical in vivo use.

17 June 2020 in Optics Letters
Verified
Journal Article
Closed access
LCLorenzo Colombo
Lorenzo Colombo
MPMarco Pagliazzi
Marco Pagliazzi
Sanathana Konugolu Venkata SekarSanathana Konugolu Venkata Sekar
Sanathana Konugolu Venkata Sekar
DCDavide Contini
Davide Contini
Turgut DurduranTurgut Durduran
Turgut Durduran
APAntonio Pifferi
Antonio Pifferi
Time-domain diffuse correlation spectroscopy (TD-DCS) is a newly emerging optical technique that exploits pulsed, yet coherent light to non-invasively resolve the blood flow in depth. In this work, we have explored TD-DCS at longer wavelengths compared to those previously used in literature (i.e., 750–850 nm). The measurements were performed using a custom-made titanium-sapphire mode-locked laser, operating at 1000 nm, and an InGaAs photomultiplier as a detector. Tissue-mimicking phantoms and in vivo measurements during arterial arm cuff occlusion in n = 4 adult volunteers were performed to demonstrate the proof of concept. We obtained a good signal-to-noise ratio, following the hemodynamics continuously with a relatively fast (1 Hz) sampling rate. In all the experiments, the auto-correlation functions show a decay rate approximately five-fold slower compared to shorter wavelengths. This work demonstrates the feasibility of in vivo TD-DCS in this spectral region and its potentiality for biomedical applications.

15 June 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
PLPranav Lanka
Pranav Lanka
LYLin Yang
Lin Yang
DODavid Orive-Miguel
David Orive-Miguel
JVJoshua D. Veesa
Joshua D. Veesa
STSusanna Tagliabue
Susanna Tagliabue
APAntonio Pifferi
Antonio Pifferi
Diffuse optics (DO) encompasses a range of photonics tools based on the study of random photon migration in highly scattering media—biological tissues in particular. Due to its unique features, DO is emerging as a powerful means for clinical or homecare diagnostics.1 The basic physics of DO is related to the detection of temporal or spatial alteration in photon distribution re-emitted on the tissue surface.2 Due to the low power (typically few mW) of injected near-infrared light (600- to 1100-nm range), DO is inherently noninvasive. The photon temporal (or spatial) distribution carries information on the absorption—ultimately related to tissue chemical composition, such as water, lipid, collagen content, oxy- and deoxy-hemoglobin concentration, cytochrome c-oxidase3—and scattering properties—linked to tissue microstructure. Further, DO is one of the few noninvasive modalities capable of providing functional information, e.g., brain or muscle activation.4 It can be operated noncontact through remote light illumination and collection.5 It explores the tissue well below the skin at depths of up to 2 to 4 cm. It can provide quantitative operator-independent assessment of the tissue status, such as hemoglobin oxygenation level in the brain. Finally, it is highly scalable, sharing the same technology from large clinical tomographic systems down to wearable devices or homecare appliances.6 For all these aspects, DO is attracting more and more interest in many fields, such as monitoring vital signs like brain oxygenation in critical care or during interventions,7 tumor diagnostics as for breast cancer,8 investigating the impact of lifestyle and nutrition on our body,9 or other fields such as neuroscience and psychology,10 sports, and leisure.11 Even further, the operator independence, the depth sensitivity, and the scalability in addition to noninvasiveness make this option attractive for telemedicine and homecare of patients remotely.

12 July 2019 in Neurophotonics
Verified
Journal Article
Open access
PDF file
LCLorenzo Colombo
Lorenzo Colombo
MPMarco Pagliazzi
Marco Pagliazzi
Sanathana Konugolu Venkata SekarSanathana Konugolu Venkata Sekar
Sanathana Konugolu Venkata Sekar
DCDavide Contini
Davide Contini
Alberto Dalla MoraAlberto Dalla Mora
Alberto Dalla Mora
APAntonio Pifferi
Antonio Pifferi
Diffuse correlation spectroscopy (DCS) is an optical technique that measures the scatterer’s motion in diffusive media, traditionally, by injecting a coherent continuous wave (CW) laser beam in a turbid sample and by characterizing the speckle fluctuations by their intensity autocorrelation function. Afterward, using a correlation diffusion model, the motion of red blood cells in the microvasculature is estimated, which has been shown to be proportional to local blood flow (BF).1 The technique is an advancement over diffuse wave spectroscopy,2 which is widely used in the study of nonbiological media. Over the last two decades, DCS has emerged as a promising technique for many clinical applications since it provides a direct measure of BF in deep (>1  cm) tissues.

16 May 2018 in Optics Letters
Verified
Journal Article
Open access
PDF file
MPM. Pagliazzi
M. Pagliazzi
Sanathana Konugolu Venkata SekarSanathana Konugolu Venkata Sekar
Sanathana Konugolu Venkata Sekar
LSLaura Di Sieno
Laura Di Sieno
LCL. Colombo
L. Colombo
Turgut DurduranTurgut Durduran
Turgut Durduran
Alberto Dalla MoraAlberto Dalla Mora
Alberto Dalla Mora
We demonstrate time domain diffuse correlation spectroscopy at quasi-null source-detector separation by using a fast time-gated single-photon avalanche diode without the need of time-tagging electronics. This approach allows for increased photon collection, simplified real-time instrumentation, and reduced probe dimensions. Depth discriminating, quasi-null distance measurement of blood flow in a human subject is presented. We envision the miniaturization and integration of matrices of optical sensors of increased spatial resolution and the enhancement of the contrast of local blood flow changes.

19 February 2021 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
MPMarco Pagliazzi
Marco Pagliazzi
LCLorenzo Colombo
Lorenzo Colombo
EVErnesto E. Vidal-Rosas
Ernesto E. Vidal-Rosas
TDTanja Dragojević
Tanja Dragojević
VPVeronika Parfentyeva
Veronika Parfentyeva
Turgut DurduranTurgut Durduran
Turgut Durduran
Time (or path length) resolved speckle contrast optical spectroscopy (TD-SCOS) at quasi-null (2.85 mm) source-detector separation was developed and demonstrated. The method was illustrated by in vivo studies on the forearm muscle of an adult subject. The results have shown that selecting longer photon path lengths results in higher hyperemic blood flow change and a faster return to baseline by a factor of two after arterial cuff occlusion when compared to SCOS without time resolution. This indicates higher sensitivity to the deeper muscle tissue. In the long run, this approach may allow the use of simpler and cheaper detector arrays compared to time resolved diffuse correlation spectroscopy that are based on readily available technologies. Hence, TD-SCOS may increase the performance and decrease cost of devices for continuous non-invasive, deep tissue blood flow monitoring.