Jorge Castizo-Olier

Dr. Jorge Castizo-Olier

Fundació TecnoCampus Mataró-Maresme
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Jorge Castizo-OlierJorge Castizo-Olier
Jorge Castizo-Olier
AIAlfredo Irurtia
Alfredo Irurtia
MJMonèm Jemni
Monèm Jemni
MCMarta Carrasco-Marginet
Marta Carrasco-Marginet
RFRaúl Fernández-García
Raúl Fernández-García
FRFerran A Rodríguez
Ferran A Rodríguez
Bioelectrical impedance vector analysis (BIVA) is a general concept that includes all methodologies used in the analysis of the bioelectrical vector, whereas the "classic" BIVA is a patented methodology included among these methods of analysis. Once this was clarified, the systematic review of the literature provides a deeper insight into the scope and range of application of BIVA in sport and exercise. The main goal of this work was to systematically review the sources on the applications of BIVA in sport and exercise and to examine its usefulness and suitability as a technique for the evaluation of body composition, hydration status, and other physiological and clinical relevant characteristics, ultimately to trace future perspectives in this growing area, including a proposal for a research agenda. Systematic literature searches in PubMed, SPORTDiscus and Scopus databases up to July, 2017 were conducted on any empirical investigations using phase-sensitive bioimpedance instruments to perform BIVA within exercise and sport contexts. The search included healthy sedentary individuals, physically active subjects and athletes. Nineteen eligible papers were included and classified as sixteen original articles and three scientific conference communications. Three studies analysed short-term variations in the hydration status evoked by exercise/training through whole-body measurements, eleven assessed whole-body body composition changes induced by long-term exercise, four compared athletic groups or populations using the whole-body assessment, and two analysed bioelectrical patterns of athletic injuries or muscle damage through localised bioimpedance measurements. BIVA is a relatively new technique that has potential in sport and exercise, especially for the assessment of soft-tissue injury. On the other hand, the current tolerance ellipses of “classic” BIVA are not a valid method to identify dehydration in individual athletes and a new approach is needed. “Specific” BIVA, a method which proposes a correction of bioelectrical values for body geometry, emerges as the key to overcome “classic” BIVA limitations regarding the body composition assessment. Further research establishing standardised testing procedures and investigating the relationship between physiology and the bioelectrical signal in sport and exercise is needed.

7 June 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MCMarta Carrasco-Marginet
Marta Carrasco-Marginet
Jorge Castizo-OlierJorge Castizo-Olier
Jorge Castizo-Olier
LRLara Rodríguez-Zamora
Lara Rodríguez-Zamora
Xavier IglesiasXavier Iglesias
Xavier Iglesias
FRFerran A Rodríguez
Ferran A Rodríguez
AIAlfredo Irurtia
Alfredo Irurtia
The assessment of body hydration is a complex process, and no measurement is valid for all situations. Bioelectrical impedance vector analysis (BIVA) has emerged as a relatively novel technique for assessing hydration status in sports. We applied BIVA a) to determine hydration changes evoked by an intense synchronized swimming (SS) training session; b) to characterize the sample of young elite swimmers in relation with a nonathletic reference population; and c) to generate its 50%, 75% and 95% percentiles of the bioelectrical variables. Forty-nine elite SS female swimmers of two age categories, comen (Co: 13.9 ± 0.9 years, n = 34) and junior (Jr: 16.3 ± 0.6 years, n = 15), performed a long, high intensity training session. Body mass (BM) and bioelectrical variables (R, resistance; Xc, reactance; PA, phase angle; and Z, impedance module) were assessed pre- and post-training. BIVA was used to characterize 1) the distribution pattern of the bioelectrical vector (BIA vector) for both age groups, and 2) pre- to post-training BIA vector migration. Bioelectrical variables were also correlated with BM change values. Most swimmers were mostly located outside the 75% and some beyond the 95% percentile of the bioelectrical tolerance ellipses of the general population. The BIA vector showed statistically significant differences in both Co (T2 = 134.7, p = 0.0001) and Jr (T2 = 126.2, p < 0.001). Both groups were also bioelectrically different (T2 = 17.6, p < 0.001). After the training session, a decrease in BM (p = 0.0001) and an increase in BIA variables (p = 0.01) was observed. BIVA also showed a significant pre-post vector migration both in Co (T2 = 82.1; p < 0.001) and Jr (T2 = 41.8; p < 0.001). No correlations were observed between BM changes and bioelectrical variables. BIVA showed specific bioelectrical characteristics in young elite SS athletes. Considering the decrease in BM and the migration of the BIA vector, we conclude that the homeostatic hydration status of these young elite female swimmers was affected by the execution of intense training sessions. From a methodological perspective, BIVA appears to be sensitive enough to detect subtle hydration changes, but further research is needed to ensure its validity and reliability. Moreover, these findings highlight the importance of ensuring adequate fluid intake during training in young SS athletes.

14 September 2021 in Frontiers in Physiology
Verified
Journal Article
Open access
ÁCÁlex Cebrián-Ponce
Álex Cebrián-Ponce
AIAlfredo Irurtia
Alfredo Irurtia
MCMarta Carrasco-Marginet
Marta Carrasco-Marginet
GSGonzalo Saco-Ledo
Gonzalo Saco-Ledo
MGMontserrat Girabent-Farrés
Montserrat Girabent-Farrés
Jorge Castizo-OlierJorge Castizo-Olier
Jorge Castizo-Olier
Background: Electrical impedance myography (EIM) is a non-invasive method that provides information about muscle health and changes that occur within it. EIM is based on the analysis of three impedance variables: resistance, reactance, and the phase angle. This systematic review of the literature provides a deeper insight into the scope and range of applications of EIM in health and physical exercise. The main goal of this work was to systematically review the studies on the applications of EIM in health and physical exercise in order to summarize the current knowledge on this method and outline future perspectives in this growing area, including a proposal for a research agenda. Furthermore, some basic assessment principles are provided.Methods: Systematic literature searches on PubMed, Scopus, SPORTDiscus and Web of Science up to September 2020 were conducted on any empirical investigations using localized bioimpedance devices to perform EIM within health and physical exercise contexts. The search included healthy individuals, elite soccer players with skeletal muscle injury, and subjects with primary sarcopenia. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist was used to develop the systematic review protocol. The quality and risk of bias of the studies included were assessed with the AQUA tool.Results: Nineteen eligible original articles were included in this review, which were separated into three tables according to the nature of the study. The first table includes six studies on the bioelectrical characterization of muscle. The second table includes five studies analyzing muscle changes in injured elite soccer players. The third table includes studies on the short-, medium-, and long-term bioelectrical adaptations to physical exercise.Conclusions: EIM has been used for the evaluation of the muscle condition in the clinical field over the last few years, especially in different neuromuscular diseases. It can also play an important role in other contexts as an alternative to complex and expensive methods such as magnetic resonance imaging. However, further research is needed. The main step in establishing EIM as a valid tool in the scientific field is to standardize the protocol for performing impedance assessments.

29 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Jorge Castizo-OlierJorge Castizo-Olier
Jorge Castizo-Olier
TSToni Solà-Perez
Toni Solà-Perez
Jorge Castizo-OlierJorge Castizo-Olier
Jorge Castizo-Olier
MCMarta Carrasco-Marginet
Marta Carrasco-Marginet
ARAlex Roy
Alex Roy
AIAlfredo Irurtia
Alfredo Irurtia
This study compared subcutaneous adipose tissue (SAT) measurements using a skinfold caliper and Renco Lean-Meater Series 12 A-mode portable ultrasound scanner (A-US). It aimed to assess their inter- and intra-rater reliability and measure the agreement between both methods. Eighty-four volunteers of different fitness levels were divided into three groups by Ʃ6 skinfolds: G1 ≤ 55 mm (n = 33 males); G2 > 55 mm (n = 32 males); G3 = 98.0 ± 52.3 mm (n = 19 females). Triceps, subscapular, biceps, iliac crest, supraspinal, abdominal, front thigh and medial calf were assessed by ultrasound and skinfolds. Two technicians for both tools performed triplicate measures. Intraclass correlation (ICC), technical error of measurement (TEM) and coefficients of variation (CVs) were applied for test-retest and inter-rater reliability. Non-Parametric statistics were used in order to establish possible statistical differences and correlation between skinfolds thickness and uncompressed subcutaneous adipose tissue thickness from ultrasound. The amount of agreement between both methods was assessed with Lin’s coefficient and a scatterplot of all site locations. A Bland-Altman plot was constructed to establish limits of agreement between groups and regression analysis was employed to assess the ability of skinfolds to explain the variance of ultrasound. Test-retest ICC for skinfolds and ultrasound were higher than 0.989 and 0.793, respectively. Inter-rater ICC for skinfolds was 0.999 with a 95% CI of 0.995 to 0.999 and for ultrasound was 0.755 with a much larger 95% CI of 0.622 to 0.841. TEMs (> 8.50%) and CVs (> 6.72%) compromised ultrasound reliability. Statistical differences were found in most of the analysed anatomical sites (p < 0.001) except in biceps G2 (Z = -1.150, p = 0.25) and G3 (Z = -1.309, p = 0.19). Good correlations (r > 0.7, p ≤ 0.05) were reported at almost all anatomical sites and groups except for biceps (G1: Rho = 0.26, p = 0.140) and abdominal (G2: Rho = -0.16, p = 0.38; G3: Rho = 0.43, p = 0.068). Lin’s concordance correlation coefficient registered low values of agreement between skinfolds and A-mode ultrasound (ranged from—0.009–0.646). The scatterplot and the estimated regression line drawn through the midst of all anatomical sites of the whole sample had a slope of 0.51 and R2 adjusted = 0.62 was obtained. The combined analysis between the Bland-Altman plot and the linear regression showed that specifically in the G2 and G3 groups, as the SAT increases the differences between skinfolds and ultrasounds measurements also increases. The Renco Lean-Meater ultrasound is not interchangeable with skinfold measures. Its utility is questionable, particularly for assessing SAT in active adult populations. Its poor test-retest and inter-rater reliability as well as the lack of agreement when compared to the skinfolds would exclude the free use of the A-mode ultrasound scanner in its hypothetical replacing of the classical calipers.

1 April 2021 in Clinical Nutrition
Verified
Journal Article
Closed access
SSSilvia Stagi
Silvia Stagi
AIAlfredo Irurtia
Alfredo Irurtia
JRJoaquim Rosales Rafel
Joaquim Rosales Rafel
SCStefano Cabras
Stefano Cabras
RBRoberto Buffa
Roberto Buffa
Elisabetta MariniElisabetta Marini
Elisabetta Marini

4 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
EMEsther Mur-Gimeno
Esther Mur-Gimeno
Francesco CampaFrancesco Campa
Francesco Campa
Badicu GeorgianBadicu Georgian
Badicu Georgian
Jorge Castizo-OlierJorge Castizo-Olier
Jorge Castizo-Olier
EPElisabet Palomera
Elisabet Palomera
Raquel SebioRaquel Sebio
Raquel Sebio
Muscle contractile properties in clinical practice are often measured using either subjective scales or high-cost, inaccessible equipment. In this randomised cross-over study, we aimed to explore the use of tensiomyography (TMG) to assess changes in muscle contractile properties after cold- and warm-water immersion. The muscle contractile properties of the biceps femoris (BF) were assessed using TMG in 12 healthy active men (mean age 23 ± 3 years, Body Mass Index 22.9 ± 1.3 kg/m2) before and after a 20-min warm- or cold-water immersion over a period of 40 min. Muscle displacement (Dm) and contraction time (Tc) were registered as the main variables of the study. There was a significant condition by time interaction for Dm (p < 0.01). Post hoc analysis showed that, compared to the baseline, there was an increase in Dm 40 min after warm-water immersion (p < 0.01) and a decrease at 10 min after cold-water immersion (p < 0.01). No significant effect was found for Tc. Our results indicate that muscle contractile properties are affected by water temperature and time after the immersion; therefore, these factors should be taken into account when water-immersion is used as a recovery strategy.