Min Guan

Prof. Min Guan


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2012 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
XCXinbo Chu
Xinbo Chu
MGMin Guan
Min Guan
LLLinsen Li
Linsen Li
YZYang Zhang
Yang Zhang
FZFeng Zhang
Feng Zhang
YZYiping Zeng
Yiping Zeng

11 December 2009 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
LLLinsen Li
Linsen Li
MGMin Guan
Min Guan
GCGuohua Cao
Guohua Cao
YLYiyang Li
Yiyang Li
YZYiping Zeng
Yiping Zeng

31 October 2017 in RSC Advances
Verified
Journal Article
Open access
PDF file
MGMin Guan
Min Guan
LNLitao Niu
Litao Niu
YZYang Zhang
Yang Zhang
XLXingfang Liu
Xingfang Liu
YLYiyang Li
Yiyang Li
YZYiping Zeng
Yiping Zeng
Space charge capacitance and the physical mechanism of negative capacitance in organic light-emitting diodes (OLEDs) by transient current response analysis are investigated for the first time.

1 November 2020 in AIP Advances
Verified
Journal Article
Open access
PDF file
JLJiaming Luo
Jiaming Luo
SLSufang Li
Sufang Li
MXMengke Xu
Mengke Xu
MGMin Guan
Min Guan
MYMengxi Yang
Mengxi Yang
YZYiping Zeng
Yiping Zeng
The high electron mobility transistor (HEMT)-based biosensors are highly competitive in the ultimate application of portable and point-of-care testing. Herein, we have demonstrated highly sensitive and real-time detection of cardiac troponin I (cTnI), a biomarker for the diagnosis of acute myocardial infarction (AMI) using AlGaAs/GaAs HEMT-based biosensors. The device has achieved a lower detection limit of 1 pg/ml in the buffer solution and less than 30 s response time, which demonstrated significant promise in the early diagnosis and screening of AMI. In addition, our results are consistent with the enzyme-linked immunosorbent assay according to the AMI patient’s blood test results. Furthermore, by comparing the two HEMT structures, we also calculated the equilibrium dissociation constant (KD) of the cTnI and cTnI antibody and analyzed the sensing mechanism. The results show that this method is very promising for early diagnosis of AMI.

26 August 2021 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
NCNing Cui
Ning Cui
MGMin Guan
Min Guan
MXMengke Xu
Mengke Xu
CZChenfeng Zhao
Chenfeng Zhao
HSHongyan Shao
Hongyan Shao
YZYiping Zeng
Yiping Zeng

9 June 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MXMengke Xu
Mengke Xu
MGMin Guan
Min Guan
NCNing Cui
Ning Cui
CZChenfeng Zhao
Chenfeng Zhao
YZYang Zhang
Yang Zhang
SLSifang Li
Sifang Li
Herein, we designed several structures of GaAs/AlGaAs extended gate high electron mobility transistors (EG-HEMT) for cTnI detection, in order to explore the mechanism of bio-detection, the limit of detection (LOD) as well as the application in clinical detection. The experiment carried out that 50y structure of EG-HEMT biosensor, whose extended electrode is 50 times as large as the gate, has highest biological regulation ability ( δ). Meanwhile, the concentration range of cTnI detection using 50y EG-HEMT biosensor is about 100 fg ml -1 to 10 μg ml -1 , which is much broader than that of Unicel Dxl800 (usually be used in clinical detection). Furthermore, due to the influence of parasitic resistance and other factors, δ increases with the increase of y, but the rising rate of δ decreases at the same time. By comparing the detecting results of clinical samples, 30y EG-HEMT is the best in the detection of cTnI concentration with a relative error of 6%. In a higher concentration range, it is more accurate than that of the Unicel Dxl800, breaking through its limit.