Ambient air pollution is a well-recognized risk for various diseases including asthma and heart diseases. However, it remains unclear whether air pollution may also be a risk of ocular allergic diseases. Using a web-based, nation-wide, cross-sectional study design, we examined whether the level of ambient air pollution is significantly associated with the prevalence of ocular allergic diseases. A web-based questionnaire was posted to invite the participants who are members of the Japan Ophthalmologist Association and their family members. The answers from 3004 respondents were used to determine whether there were significant associations between the level of the pollutants and the prevalence of ocular allergic diseases. The study period was between March to May 2017. The data of the air pollutants during 2012 to 2016 were obtained from the National Institute for Environmental Studies. The prevalence of allergic diseases was calculated by post stratification and examined for significant associations with the level of pollutants using multiple logistic regression analyses. The prevalence of seasonal allergic conjunctivitis, perennial allergic conjunctivitis, atopic keratoconjunctivitis (AKC), and vernal keratoconjunctivitis (VKC) in Japan was 45.4%, 14.0%, 5.3%, and 1.2%, respectively. The high prevalence of the severe forms of allergic conjunctivitis, including AKC and VKC, were significantly associated with the levels of the air pollutants. The prevalence of AKC was significantly associated with the levels of NO2 with an odds ratio (OR) of 1.23 (per quintile). The prevalence of VKC was significantly associated with the levels of NOx and PM10 with ORs of 1.72 and 1.54 respectively. The significant associations between the prevalence of AKC and VKC and the levels of air pollutants indicate that clinicians need to be aware that air pollutants may pose serious risks of vision threatening severe ocular allergy.
Background: Visual impairments and age-related eye diseases need to be detected and treated in a timely manner. However, this is often hampered by lack of appropriate medical equipment. We have invented a portable, recordable, and smartphone-attachable slit-lamp device, called the Smart Eye Camera (SEC). The aim of this study was to compare evaluating nuclear cataract (NUC) between the SEC and the conventional, non-portable slit-lamp microscope. Methods: A total of 128 eyes of 64 Japanese patients (mean age: 73.95 ± 9.28 years; range: 51‒92 years; female: 34) were enrolled. The NUC was classified into four grades (grade 0 to 3) based on three standard photographs of nuclear opacities according to the WHO classification by ophthalmologists. An ophthalmic healthcare assistant (non-ophthalmologist) filmed the eyes in video mode by the SEC and an ophthalmologist graded the NUC. Grade correlation and inter-rater reproducibility were determined. Results: NUC grading by the two approaches correlated significantly (both eyes: r = 0.871 [95%CI: 0.821 to 0.907; p < 0.001]). Inter-rater agreement was high (weighted κ = 0.807 [95%CI: 0.798 to 0.816; p < 0.001]). Conclusions: This study suggests that the SEC is as reliable as the conventional non-portable slit-lamp microscope for evaluating NUC.
1 August 2016 in Journal of Allergy and Clinical Immunology
Allergic conjunctival disease (ACD) is an inflammatory disease of the conjunctiva that is mainly caused by type I hypersensitivity response to allergens and accompanied by subjective symptoms and other findings induced by antigens. ACD is classified as allergic conjunctivitis, atopic keratoconjunctivitis, vernal keratoconjunctivitis, and giant papillary conjunctivitis. This article summarizes the third edition of the Japanese guidelines for allergic conjunctival diseases published in 2021 and outlines the diagnosis, pathogenesis, and treatment of ACD. Since the introduction of immunosuppressive eye drops, the treatment strategies for severe ACDs have significantly changed. To clarify the recommended standard treatment protocols for ACD, the advantages and disadvantages of these treatments were assessed using clinical questions, with a focus on the use of steroids and immunosuppressive drugs. This knowledge will assist healthcare providers and patients in taking an active role in medical decision making.
Background: The incidence of allergic conjunctival diseases (ACDs) is gradually increasing worldwide. Both ophthalmologists and non-ophthalmologists prescribe eye drops to treat ACDs; however, there are many cases which are treated without sufficient examination and diagnosis of the eyes. We have invented a portable, recordable, and smartphone-attachable slit-lamp device—Smart Eye Camera (SEC). The purpose of this study was to compare the diagnostic abilities of ACDs between the SEC and the conventional, non-portable slit-lamp microscope. Methods: This prospective observational study included 32 eyes of 17 Japanese patients (mean age: 21.5 ± 14.8 years; range: 11–51 years; female: 5). The severity of 10 objective signs in the palpebral conjunctiva, bulbar conjunctiva, limbus, and cornea were scored on a grading scale of 0 to 4 (0 = normal; 1+ = mild; 2+ = moderate; 3+ = severe), respectively. First, the conventional slit-lamp microscope was used to examine the grade of the ACDs. Second, another ophthalmologist filmed the eyes using the SEC and two other ophthalmologists evaluated the grades on another day. The correlation and inter-rater reproducibility in total scores among the two devices were determined. Results: Total scores of clinical signs, evaluated by the two approaches, correlated significantly (both eyes: r = 0.918 (95% CI: 0.839 to 0.959; p < 0.001)), with substantial inter-rater agreement (weighted κ value = 0.631 (95% CI: 0.601 to 0.661; p < 0.001)). Conclusions: The SEC is as reliable as the conventional non-portable slit-lamp microscope for assessing ACDs.