Nicolaas Bernardus Roozen

Prof. Nicolaas Bernardus Roozen

KU Leuven
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2007 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
ILI. Lopez
I. Lopez
RBR.E.A. Blom
R.E.A. Blom
NRNicolaas Bernardus Roozen
Nicolaas Bernardus Roozen
HNH. Nijmeijer
H. Nijmeijer

1 October 2013 in Applied Acoustics
Verified
Journal Article
Closed access
NRNicolaas Bernardus Roozen
Nicolaas Bernardus Roozen
QLQ. Leclère
Q. Leclère

1 June 2015 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
NRNicolaas Bernardus Roozen
Nicolaas Bernardus Roozen
LLL. Labelle
L. Labelle
Monika RychtarikovaMonika Rychtarikova
Monika Rychtarikova
CGC. Glorieux
C. Glorieux

13 November 2015 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
LLLiwang Liu
Liwang Liu
KZKuo Zhong
Kuo Zhong
Troy MunroTroy Munro
Troy Munro
SASalvador Alvarado
Salvador Alvarado
RCRenaud Côte
Renaud Côte
CGChrist Glorieux
Christ Glorieux
Neural network recognition of features of the fluorescence spectrum of a thermosensitive probe is exploited in order to achieve fluorescence-based thermometry with an accuracy of 200 mK with 100 MHz bandwidth, and with high robustness against fluctuations of the probe laser intensity used. The concept is implemented on a rhodamine B dyed mixture of copper chloride and glycerol, and the temperature dependent fluorescence is investigated in the temperature range between 234 K and 311 K. The spatial dependence of the calibrated amplitude and phase of photothermally induced temperature oscillations along the axis of the excitation laser are determined at different modulation frequencies. The spatial and frequency dependence of the extracted temperature signals is well fitted by a 1D multi-layer thermal diffusion model. In a time domain implementation of the approach, the gradual temperature rise due to the accumulation of the DC component of the heat flux supplied by repetitive laser pulses as well the immediate transient temperature evolution after each single pulse is extracted from acquired temporal sequences of fluorescence spectra induced by a CW green laser. A stroboscopic implementation of fluorescence thermometry, using a pulsed fluorescence evoking probe laser, is shown to achieve remote detection of temperature changes with a time resolution of 10 ns.

1 January 2016 in Acta Acustica united with Acustica
Verified
Journal Article
Closed access
Monika RychtarikovaMonika Rychtarikova
Monika Rychtarikova
HMHerbert Muellner
Herbert Muellner
VCVojtech Chmelík
Vojtech Chmelík
NRNicolaas Bernardus Roozen
Nicolaas Bernardus Roozen
DUDaniel Urbán
Daniel Urbán
CGChrist Glorieux
Christ Glorieux
This article presents a perceptual comparison of the loudness of a large range of 64 different typical “living room” sounds transmitted through two different walls: (1) a light-weight wall, composed of gypsum boards mounted on metal “C” studs and (2) a heavy-weight wall, built out of lime sand bricks plastered on one side. The two walls had different (laboratory measured) sound insulation spectra, but their Rw + C50−5000 rating was the same: 52 dB. Compared to the heavy-weight wall, the mass-spring-mass-type light-weight wall had better sound insulation properties in the middle frequency range and worse at low frequencies below 100 Hz and above 3150 Hz. Listening subjects had to choose the loudest stimuli between a pair of sounds (as transmitted through the lightweight and the masonry wall) presented through headphones in random order with one repetition, following a two-alternative forced choice (2AFC) procedure. Two sets of listening tests were conducted in this study, playing stimuli at realistic sound level and on artificially overall increased level. The listening experiments revealed significant differences in subjective assessment between the two types of acoustic insulation. The results also infer that the discussed single number rating does not adequately correspond with people’s perception.status: publishe

13 June 2008 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
NRNicolaas Bernardus Roozen
Nicolaas Bernardus Roozen
AKA. H. Koevoets
A. H. Koevoets
AHA. J. Den Hamer
A. J. Den Hamer
Lorentz-force-induced vibrations in MRI systems cause significant acoustic noise levels during scanning, the main acoustic noise source being the vibrating gradient coil. In this paper, a novel active vibration control technique is presented to reduce vibrations of the gradient coil, and hence, achieve a reduction of acoustic noise during scanning. The active vibration control technique uses seismic masses that are actuated by means of piezo actuators to create forces on the gradient coil counteracting its vibrations. Using four seismic mass actuators, a vibration reduction of 3-8 dB at resonance frequencies is achieved, giving an overall vibration reduction of 3 dB for a typical field gradient (FE)-echo planar imaging (EPI) gradient sequence, as substantiated by measurements. Using eight actuators, an overall vibration reduction of 5 dB is predicted for this sequence.