In order to monitor the rail base, the dispersion characteristics and propagation properties of the guided wave are studied. Firstly, two modes named as Modes V1 and V2 are selected by the semianalytical finite element method (SAFE). The region at the bottom edge can be monitored by Mode V1, while the junction of the base edge and the flange can be detected by Mode V2. Then, the characteristics in the propagation process are analyzed using the finite element method (FEM). The two modes can be separated about 0.6 ms after they are excited. Thirdly, a wave attenuation algorithm based on mean is proposed to quantify the wave attenuation. Both waves can have weak attenuation and be detected within 5 m. Finally, a mode-identified experiment is performed to validate the aforementioned analysis. And a defect detection experiment is performed to demonstrate the excellent monitoring characteristics using Mode V2. These results can be used to monitor the rail base in practice engineering.
The nanopositioning stage with a piezoelectric driver usually compensates for the nonlinear outer-loop hysteresis characteristic of the piezoelectric effect using the Prandtl–Ishlinskii (PI) model under a single-ring linear voltage, but cannot accurately describe the characteristics of the inner-loop hysteresis under the reciprocating linear voltage. In order to improve the accuracy of the nanopositioning, this study designs a nanopositioning stage with a double-parallel guiding mechanism. On the basis of the classical PI model, the study firstly identifies the hysteresis rate tangent slope mark points, then segments and finally proposes a phenomenological model—the mark-segmented Prandtl–Ishlinskii (MSPI) model. The MSPI model, which is fitted together by each segment, can further improve the fitting accuracy of the outer-loop hysteresis nonlinearity, while describing the inner-loop hysteresis nonlinearity perfectly. The experimental results of the inverse model compensation control show that the MSPI model can achieve 99.6% reciprocating linear voltage inner-loop characteristic accuracy. Compared with the classical PI model, the 81.6% accuracy of the hysteresis loop outer loop is improved.
In order to solve the problem of low precision and efficiency in the balancing process due to the movement of balance counterweights in a built-in mechanical on-line dynamic balance system, an optimization strategy for the mass compensation of the mechanical on-line dynamic balancing system is proposed, and a mass compensation optimization model is established. The optimization model takes the phase of counterweight movement as the optimization variable and the residual stress under dynamic balance as the optimization objective. Through the optimization model, the movement phase of the counterweight can be calculated, and the counterweight can be moved to a balanced position that significantly reduces the degree of unbalance. An experiment platform was built to carry out comparison experiments under different rotating speeds and unbalance levels. By comparing the residual stress, amplitude, and dynamic balancing time of the spindle before and after the balance, the accuracy of the phase of the counterweight that is calculated by the optimization model is verified. The optimized dynamic balance compensation strategy and the unoptimized were compared by experiments at different rotating speeds. The experimental results showed that, compared to the unoptimized balance, the amplitude of the spindle after optimizing balance with a dynamic balancing device can decrease by 30.39% on average, with its maximum amplitude decreasing by up 50.18%, and the balancing time can decrease by 31.72% on average, with its maximum balancing time decreasing by up to 43.86%. The research results showed that an optimization strategy can effectively improve dynamic balance efficiency and greatly reduce vibration amplitude, which provides the necessary theoretical basis for improving the running precision of the spindle system.
In order to measure the axial force in the rail, a dynamic model of discretely supported rails with axial force is first established, and the dynamic response of the rail under a hammering force is studied. First, the rail is simplified to an Euler beam, and its displacement at any point in the frequency domain is derived. Second, a hammer experiment is carried out, and its results are compared with the theoretical results to prove the theoretical derivation. Finally, the effects of axial force, varied sleeper spacings, and the number of loose fasteners on the natural frequency are studied, respectively. The results show that the axial force has a linear relationship with the natural frequencies; when there are many loose fasteners, varied sleeper spacings have a weak influence on the linear relationship between the axial force and the natural frequency; the sensitive frequency band is within 500 Hz. These conclusions indicate how to accurately measure the axial force in the rail and can be effectively applied to engineering practice.