Stefania Fichera

Dr. Stefania Fichera


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
Alessandro CiociaAlessandro Ciocia
Alessandro Ciocia
Angela AmatoAngela Amato
Angela Amato
Paolo Di LeoPaolo Di Leo
Paolo Di Leo
SFStefania Fichera
Stefania Fichera
Gabriele MalgaroliGabriele Malgaroli
Gabriele Malgaroli
STSlavka Tzanova
Slavka Tzanova
This paper presents a methodology to maximize the self-sufficiency or cost-effectiveness of grid-connected prosumers by optimizing the sizes of photovoltaic (PV) systems and electrochemical batteries. In the optimal sizing procedure, a limitation on the maximum injection in the grid can affect the energy flows, the economic effectiveness of the investments, and thus the sizing results. After the explanation of the procedure, a case study is presented, and a parametric analysis of the effect of possible injection limits is shown. The procedure is applied to size plants for an Italian domestic prosumer, whose electric load profile was measured for a year. A software program developed using the proposed methodology is also briefly presented. It is used for both research and educational purposes, both in laboratory classes and in remote lessons.

1 May 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Filippo SpertinoFilippo Spertino
Filippo Spertino
Alessandro CiociaAlessandro Ciocia
Alessandro Ciocia
Paolo Di LeoPaolo Di Leo
Paolo Di Leo
SFStefania Fichera
Stefania Fichera
Gabriele MalgaroliGabriele Malgaroli
Gabriele Malgaroli
ARAlessandro Ratclif
Alessandro Ratclif
The present paper proposes a multidisciplinary procedure to correctly design a microgrid of all-electric nZEBs (nearly Zero Energy Buildings) from both electrical and thermal points of view. The procedure is suitable for new buildings supplied by local renewables, without the use of fossil fuel and with zero emissions. First, the thermal demand of each single nZEB is assessed, as a function of the installation site, building layout and physics, and material composing the envelope. Thanks to heat pumps, the thermal demand is transformed in electric load. Thus, the total electric consumption profiles, which include user's appliances and heating/cooling, are studied and compared with Photovoltaic (PV) generation supported by electrochemical storages. Both PV and batteries are simulated thanks to appropriate models. Regarding the PV production assessment, the present work proposes an improvement with respect to the use of traditional models, and it is based on experimental results on PV generators of recent production. The design methodology is applied to a real case of “energy community” composed of three nZEB units, that will be built in the campus of Politecnico di Torino, available to students and staff. The three units share PV production and storage capacity to reach the complete grid-independence.

29 November 2019 in Energies
Verified
Journal Article
Open access
PDF file
JAJawad Ahmad
Jawad Ahmad
Alessandro CiociaAlessandro Ciocia
Alessandro Ciocia
SFStefania Fichera
Stefania Fichera
AMAli Faisal Murtaza
Ali Faisal Murtaza
Filippo SpertinoFilippo Spertino
Filippo Spertino
During their operational life, photovoltaic (PV) modules may exhibit various defects for poor sorting of electrical performance during manufacturing, mishandling during transportation and installation, and severe thermo-mechanical stresses. Electroluminescence testing and infrared thermographic imaging are the most common tests for checking these defects, but they are only economically viable for large PV plants. The defects are also manifested as abnormal electrical properties of the affected PV modules. For defect diagnosis, the appropriate parameters on their I-V curves are open circuit voltage, photo-generated current, series resistance, and the shunt resistance. The health of PV modules can be assessed by calculating these values and comparing them with the reference parameters. If these defects are diagnosed in time, the power loss is avoided and safety hazards are mitigated. This paper first presents a review of common defects in PV modules and then a review of the methods used to find the above-mentioned parameters during the normal PV operation. A simple approach to determine the resistances of the equivalent circuit is discussed. Finally, through a modification in an ordinary maximum power point tracking (MPPT) algorithm, information about the state of health of PV modules is obtained. This method is effective, especially if applied to submodule-integrated MPPT architectures.