Angela Amato

Ms. Angela Amato

Department of Energy, Politecnico di Torino (Italy)
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
Alessandro CiociaAlessandro Ciocia
Alessandro Ciocia
Angela AmatoAngela Amato
Angela Amato
Paolo Di LeoPaolo Di Leo
Paolo Di Leo
SFStefania Fichera
Stefania Fichera
Gabriele MalgaroliGabriele Malgaroli
Gabriele Malgaroli
STSlavka Tzanova
Slavka Tzanova
This paper presents a methodology to maximize the self-sufficiency or cost-effectiveness of grid-connected prosumers by optimizing the sizes of photovoltaic (PV) systems and electrochemical batteries. In the optimal sizing procedure, a limitation on the maximum injection in the grid can affect the energy flows, the economic effectiveness of the investments, and thus the sizing results. After the explanation of the procedure, a case study is presented, and a parametric analysis of the effect of possible injection limits is shown. The procedure is applied to size plants for an Italian domestic prosumer, whose electric load profile was measured for a year. A software program developed using the proposed methodology is also briefly presented. It is used for both research and educational purposes, both in laboratory classes and in remote lessons.

27 February 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Filippo SpertinoFilippo Spertino
Filippo Spertino
Angela AmatoAngela Amato
Angela Amato
GCGabriele Casali
Gabriele Casali
Alessandro CiociaAlessandro Ciocia
Alessandro Ciocia
Gabriele MalgaroliGabriele Malgaroli
Gabriele Malgaroli
The reliability of photovoltaic (PV) generators is strongly affected by the performance of Direct Current/Alternating Current (DC/AC) converters, being the major source of PV underperformance. However, generally, their reliability is not investigated at component level: thus, the present work presents a reliability analysis and the repair activity for the components of full bridge DC/AC converters. In the first part of the paper, a reliability analysis using failure rates from literature is carried out for 132 inverters (AC rated power of 350 kW each) with global AC power of 46 MW in a large scale grid-connected PV plant. Then, in the second part of the work, results from literature are compared with data obtained by analyzing industrial maintenance reports in the years 2015–2017. In conclusion, the yearly energy losses involved in the downtime are quantified, as well as their availability.

8 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
Angela AmatoAngela Amato
Angela Amato
Matteo BilardoMatteo Bilardo
Matteo Bilardo
Enrico FabrizioEnrico Fabrizio
Enrico Fabrizio
Valentina SerraValentina Serra
Valentina Serra
Filippo SpertinoFilippo Spertino
Filippo Spertino
In recent years, investigations on advanced technological solutions aiming to achieve high-energy performance in buildings have been carried out by research centers and universities, in accordance with the reduction in buildings’ energy consumption required by European Union. However, even if the research and design of new technological solutions makes it possible to achieve the regulatory objectives, a building’s performance during operation deviates from simulations. To deepen this topic, interesting studies have focused on testing these solutions on full-scale facilities used for real-life activities. In this context, a test facility will be built in the university campus of Politecnico di Torino (Italy). The facility has been designed to be an all-electric nearly Zero Energy Building (nZEB), where heating and cooling demand will be fulfilled by an air-source heat pump and photovoltaic generators will meet the energy demand. In this paper, the facility energy performance is evaluated through a dynamic simulation model. To improve energy self-sufficiency, the integration of lithium-ion batteries in a HVAC system is investigated and their storage size is optimized. Moreover, the facility has been divided into three units equipped with independent electric systems with the aim of estimating the benefits of local energy sharing. The simulation results clarify that the facility meets the expected energy performance, and that it is consistent with a typical European nZEB. The results also demonstrate that the local use of photovoltaic energy can be enhanced thanks to batteries and local energy sharing, achieving a greater independence from the external electrical grid. Furthermore, the analysis of the impact of the local energy sharing makes the case study of particular interest, as it represents a simplified approach to the energy community concept. Thus, the results clarify the academic potential for this facility, in terms of both research and didactic purposes.

16 June 2022 in Solar
Verified
Journal Article
Open access
PDF file
Filippo SpertinoFilippo Spertino
Filippo Spertino
Gabriele MalgaroliGabriele Malgaroli
Gabriele Malgaroli
Angela AmatoAngela Amato
Angela Amato
MQMuhammad Aoun Ejaz Qureshi
Muhammad Aoun Ejaz Qureshi
Alessandro CiociaAlessandro Ciocia
Alessandro Ciocia
HSHafsa Siddiqi
Hafsa Siddiqi
For a photovoltaic (PV) generator, knowledge of the parameters describing its equivalent circuit is fundamental to deeply study and simulate its operation in any weather conditions. In the literature, many papers propose methods to determine these parameters starting from experiments. In the most common circuit, there are five of these parameters, and they generally refer to specific weather conditions. Moreover, the dependence on irradiance and temperature is not investigated for the entire set of parameters. In fact, a few papers present some equations describing the dependence of each parameter on weather conditions, but some of their coefficients are unknown. As a consequence, this information cannot be used to predict the PV energy in any individual weather condition. This work proposes an innovative technique to assess the generated energy by PV modules starting from the knowledge of their equivalent parameters. The model is applied to a highly efficient PV generator with all-back contact, monocrystalline silicon technology, and rated power of 370 W. The effectiveness of the model is investigated by comparing its energy prediction with the value estimated by the most common model in the literature to assess PV energy. Generated energy is predicted by assuming PV power to be constant for a time interval of 1 min.

9 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
Diana ENESCUDiana ENESCU
Diana ENESCU
Alessandro CiociaAlessandro Ciocia
Alessandro Ciocia
UGUdayanga I. K. Galappaththi
Udayanga I. K. Galappaththi
HWHarsha Wickramasinghe
Harsha Wickramasinghe
FAFrancesco Alagna
Francesco Alagna
Valeria CocinaValeria Cocina
Valeria Cocina
This article is written within the European Project “THREE-Lanka” which has the aim of modernizing the higher education related to Renewable Energy (RE) in Sri Lanka. The paper presents the outcomes of analysing various incentive schemes to stimulate RE development. In Europe, there was substantial growth in RE installation through generous incentives in the first years. Then, to regulate this growth, in recent years, the auction system has been introduced to improve the competition among companies that install RE plants. In Sri Lanka, on the other hand, the main energy tariff policies focus on the spread of PhotoVoltaics (PV) through contributions based on the electricity fed into the grid. This paper provides an updated view of the evolution of the energy tariff policies in the relevant European countries with respect to Sri Lanka, covering some recent policy developments. Within the Sri Lankan framework, four case studies involving residential, commercial, and industrial users are outlined to suggest better mechanisms (in the case of not adequate current incentive tariff) for supporting the deployment of grid-connected PV systems in a wide power range. Such knowledge transfer in the THREE-Lanka project will demonstrate the enormous potential RE capacity in a developing country, still depending on fossil fuels but willing to follow the path towards sustainability.

3 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Angela AmatoAngela Amato
Angela Amato
Alessio CarulloAlessio Carullo
Alessio Carullo
Alessandro CiociaAlessandro Ciocia
Alessandro Ciocia
SCSimone Corbellini
Simone Corbellini
Filippo SpertinoFilippo Spertino
Filippo Spertino
MBMarco Augusto Alfredo Bertonasco
Marco Augusto Alfredo Bertonasco
The main topic of this article is the PhotoVoltaic Zero Energy Network (PVZEN) laboratory, which is an energy community for research purposes established at the Politecnico di Torino campus. The PVZEN laboratory has three users, each equipped with a PhotoVoltaic (PV) generator, lithium batteries with proper electronic converters, and emulators of electric appliances, including heat pumps. These users are capable of exchanging energy based on specific strategies conceived for maximizing the use of renewable energy sources. This work is focused on the identification of energy models that can describe the main components of the community. With the aim of providing reliable models that can enable other researchers in simulating the microgrid in different operating conditions, a monitoring system has been installed close to the relevant commercial devices, to obtain traceable measurements of electrical and environmental quantities. The reference results provided by the monitoring system allowed the multi-meter internal to the inverters to be characterized. Furthermore, the DC measurements provided by the monitoring system allowed reliable models to be identified for PV generators and storage systems. For the former, the identified models exhibited root means square errors between measured and predicted energy lower than 1 % during a time interval of about three months; for the latter, charge and discharge efficiencies and self-discharge were in agreement with expected values for the lithium batteries.