Alexander Benken

Dr. Alexander Benken


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
ABAlexander Benken
Alexander Benken
YGYogesh Gianchandani
Yogesh Gianchandani
We describe a wireless microsystem for gastrointestinal manometry that couples a microfabricated capacitive transducer to a dual-axis inductor, forming a resonant inductor-capacitor (LC) sensor within an ingestible 3D printed biocompatible capsule measuring ø 12 mm × 24 mm. An inductively coupled external telemetry unit wirelessly monitors the pressure dependent resonant frequency of the LC sensor, eliminating the need for integrated power sources within the ingested capsule. In vitro tests in saline show pressure response of −0.6 kHz/mmHg, interrogation distance up to 6 cm, and resolution up to 0.8 mmHg. In vivo functionality is validated with gastrointestinal pressure monitoring in a canine beagle over a 26-hour period.

6 July 2021 in IEEE Sensors Journal
Verified
Journal Article
Open access
YSYu Sui
Yu Sui
ABAlexander Benken
Alexander Benken
YMYushu Ma
Yushu Ma
ATAndrew Trickey-Glassman
Andrew Trickey-Glassman
TLTao Li
Tao Li
YGYogesh B. Gianchandani
Yogesh B. Gianchandani
This paper describes the design, implementation, and evaluation of an environmental logging microsystem (ELM) for operation at elevated pressure and in corrosive environments, at temperatures up to 125°C. The ELM units are intended to be deployed in large quantities, allowed to collect data, and then retrieved, interrogated, and re-charged. Powered by a rechargeable battery embedded within the system, each ELM incorporates pressure and temperature sensors, control electronics, optical communication elements, and power management and battery re-charging circuits. The pressure sensor is a customized capacitive transducer chip on a sapphire substrate; details are provided in a companion paper. The electronic components and battery used in ELM are selected on the basis of functionality and form factor; packaged components are selected for ease of assembly and for added protection against the environment. The pressure sensor, electronics and battery are assembled on a flexible circuit board, folded into a stack with dimensions 7.2 mm × 6.6 mm × 6.5 mm, and encapsulated in a steel tube filled with optically transparent silicone caulk. This encapsulation provides mechanical protection against shock and abrasion, as well as chemical protection against high salinity environments, while allowing the ambient pressure and temperature to be transferred to the sensing elements. Results are reported from high-temperature and high-pressure tests reaching 125°C and 7,250 psi in brine and other corrosive environments in laboratory conditions. Field tests that were conducted in a brine well to a maximum depth of 1,235 m are also described. The recorded data were post-processed to interpret the environmental pressure and temperature.

24 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PDPartha Pratim Dutta
Partha Pratim Dutta
ABAlexander Benken
Alexander Benken
TLTao Li
Tao Li
JOJohn Richard Ordonez-Varela
John Richard Ordonez-Varela
YGYogesh B. Gianchandani
Yogesh B. Gianchandani
Using distributed MEMS pressure sensors to measure small flow rates in high resistance fluidic channels is fraught with challenges far beyond the performance of the pressure sensing element. In a typical core-flood experiment, which may last several months, flow-induced pressure gradients are generated in porous rock core samples wrapped in a polymer sheath. Measuring these pressure gradients along the flow path requires high resolution pressure measurement while contending with difficult test conditions such as large bias pressures (up to 20 bar) and temperatures (up to 125 °C), as well as the presence of corrosive fluids. This work is directed at a system for using passive wireless inductive-capacitive (LC) pressure sensors that are distributed along the flow path to measure the pressure gradient. The sensors are wirelessly interrogated with readout electronics placed exterior to the polymer sheath for continuous monitoring of experiments. Using microfabricated pressure sensors that are smaller than ø15 × 3.0 mm3, an LC sensor design model for minimizing pressure resolution, accounting for sensor packaging and environmental artifacts is investigated and experimentally validated. A test setup, built to provide fluid-flow pressure differentials to LC sensors with conditions that mimic placement of the sensors within the wall of the sheath, is used to test the system. Experimental results show the microsystem operating over full-scale pressure range of 20,700 mbar and temperatures up to 125 °C, while achieving pressure resolution of <1 mbar, and resolving gradients of 10–30 mL/min, which are typical in core-flood experiments.

22 October 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ABAlexander Benken
Alexander Benken
YGYogesh B. Gianchandani
Yogesh B. Gianchandani
We report a high yield fabrication process based on surface micromachining of sapphire substrates and plasma-deposited thin films for pressure sensors with extraordinarily high output swing relative to baseline and parasitic capacitance. This feature allows the use of massively parallel diaphragms arrays in a single sensor chip that is read out with a single interface circuit, providing a superior full-scale range and resolution in a small footprint. Five types of sensor chips are reported, incorporating: a) a single diaphragm (ø $100 ~\mu \text{m}$ diameter); b) 18 diaphragms in parallel (ø $100 ~\mu \text{m}$ diameter); c) 85 diaphragms (ø56-ø $92 ~\mu \text{m}$ diameter); d) 8 diaphragms in parallel (ø $200 ~\mu \text{m}$ diameter); and e) 32 diaphragms in parallel (ø110-ø $150 ~\mu \text{m}$ diameter). The respective maximum gauge pressures are 30 MPa, 30 MPa, 70 MPa, 70 kPa, and 110 kPa; the respective resolutions are 1.0 kPa, 0.2 kPa, 0.5 kPa, 5.7 Pa, and 2.6 Pa. Full-scale range is defined with the upper boundary as the applied pressure at which the incremental response falls below 30% of the incremental response at the lower boundary (which is approximated as atmospheric pressure). In two of these cases, varying diameters are used to reduce the inherent non-linearity of the sensor response over the full-scale pressure range. The 85-diaphragm sensor, intended for downhole pressure sensing, provides a capacitance response of 0.46 fF/kPa and 7.1 pF ${C}_{0}$ . The 32-diaphragm sensor, intended for lower operating pressures, provides capacitance response of 29 fF/kPa and 11.5 pF ${C}_{0}$ . The fabrication process, design features, and experimental results are presented.

22 June 2022 in SPE Journal
Verified
Journal Article
Open access
PDF file
NVNeeharika Vellaluru
Neeharika Vellaluru
PDPartha Pratim Dutta
Partha Pratim Dutta
ABAlexander Benken
Alexander Benken
JBJean-Gregoire Boero-Rollo
Jean-Gregoire Boero-Rollo
JOJohn-Richard Ordonez-Varela
John-Richard Ordonez-Varela
YGYogesh Gianchandani
Yogesh Gianchandani
Summary: We report an autonomous microsystem intended for deployment in harsh fluid environments. The microsystem incorporates pressure, temperature, and inertial sensors and Bluetooth Low Energy (BLE) communication electronics; power is supplied via secondary battery, recharged using Qi wireless power transfer. Sensors and electronics are incorporated within a circuit board measuring ø26.7 × 1.5 mm3 which is embedded in a package with volume <25 cm3 and density 96 hours. The VitonTM packaging was tested in H2S, diesel fuel, and 15% brine. Microsystems were then successfully evaluated in field deployment conditions in an oilwell to a depth of 1290 m, recording pressure, temperature, and inertial data.