Ahmed H. A. Adam

Dr. Ahmed H. A. Adam


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2024 in IEEE Access
Verified
Journal Article
Open access
AAAhmed H. A. Adam
Ahmed H. A. Adam
JCJiawei Chen
Jiawei Chen
MXMinghan Xu
Minghan Xu
Salah KamelSalah Kamel
Salah Kamel
GMGhazally I. Y. Mustafa
Ghazally I. Y. Mustafa
EAEmad M. Ahmed
Emad M. Ahmed
DC microgrids, which use various energy sources, require an energy storage system (ESS) to stabilize the grid systems. Multiport active bridge (MAB) bidirectional DC-DC converters offer several advantages over other converters, including higher power density, bidirectional functionality, reduced component counts, soft switching ability, and a reduced number of conversion stages. However, these converters are affected by the cross-coupling effect of the control variable, with the power dissipated at each port significantly impacting the system response to step changes. This causes unstable DC bus voltage, slow dynamic response, large overshoot, and limits its reliability. To address this issue, a power decoupling with feedforward compensation based on model predictive control (MPC) and fuzzy compensation control (FCC) was developed. The proposed control strategy can achieve good transient performance (lower settling time, overshoot/undershoot in the controlled variables), excellent decoupling control performance, and high control flexibility with good precision to comply with DC voltage regulations. This article investigates the PD-MPC-FCC and its implementation in a triple active bridge (TAB) converter with multi-winding high-frequency transformers. The proposed MPC-FFC integrates MPC with fuzzy compensation control. The MPC aims to obtain more precise current reference values and implement current feedforward control to stabilize the DC bus voltage, while the FCC adaptively compensates for steady-state voltage errors. A hardware-in-the-loop (HIL) experimental case study using Typhoon 602 validates the TAB converter’s performance with the proposed PD-MPC-FCC strategy. Additionally, a comparison with previous works confirms the effectiveness of the proposed method. The HIL experimental setup and comparative analysis results demonstrate that the proposed method is effective, providing faster dynamic characteristics and port power decoupling operation capability.

10 May 2023 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
PDF file
AAAhmed H. A. Adam
Ahmed H. A. Adam
JCJiawei Chen
Jiawei Chen
Salah KamelSalah Kamel
Salah Kamel
HZHamed Zeinoddini-Meymand
Hamed Zeinoddini-Meymand
This study offers a thorough examination of the zero voltage switching (ZVS) operation range and deadband conditions for a bidirectional DC-DC converter with phase shift control, featuring dual H-bridge. The analysis considers the soft switching range of the DAB converter, accounting for the impact of the headband and the ZVS capacitor. By applying the differential equation of the circuit during deadband time, a sufficient constraint for the input and output bridges can be calculated. The findings indicate that as the output voltage increases, the minimum phase shift value required to achieve ZVS decreases, and expanding the phase shift value will expand the ZVS range and reduce switching losses. The study provides simulation results for various operating conditions, validating the theoretical analysis of the proposed system. In addition, the results furnish information about the circuit behavior during the deadband and waveforms. Finally, MATLAB/SIMULINK verifies the simulation results for different operating stages.

10 February 2026 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AAAhmed H. A. Adam
Ahmed H. A. Adam
SKSalah Kamel
Salah Kamel
Mohamed Hosny HassanMohamed Hosny Hassan
Mohamed Hosny Hassan
GMGhazally I. Y. Mustafa
Ghazally I. Y. Mustafa
The rising global energy demand, along with the growth of electric power transmission and distribution systems, has intensified the need to incorporate renewable energy sources to foster sustainable development. However, achieving optimal operation within such systems poses significant challenges due to the stochastic nature of renewable energy generation. As a result, the optimal power flow (OPF) problem becomes increasingly complex when addressing the inherent uncertainty of renewable inputs. This study presents a new approach to addressing the OPF problem through the implementation of a hybrid Weighted Mean of Vectors Optimization Algorithm (INFO) based on artificial rabbits optimization (ARO) called ARINFO technique. The proposed ARINFO algorithm aims to reach an exploration-exploitation balance to improve search efficiency. To effectively manage the uncertainty associated with renewable energy output, modifications are implemented on standard test systems: in the IEEE 30-bus system (consisting of 30 buses, 6 thermal generators, and 41 branches), three thermal units are substituted with two wind turbines and one solar photovoltaic (PV) generator; a similar modification is made to the IEEE 57-bus system (which includes 57 buses, 7 thermal generators, and 80 branches) and large scale test system (IEEE 118-bus system). The stochastic characteristics of wind and solar power are modeled using Weibull and lognormal distributions, respectively. Their impact on the OPF problem is examined by incorporating reserve and penalty costs for overestimating and underestimating power output. Load demand variability is also assessed through standard probability density functions (PDF) to capture its uncertainty. Furthermore, operational constraints of thermal generators, such as ramp rate limits, are considered. The performance of the ARINFO algorithm is rigorously evaluated through 23 benchmark functions and the CEC-2022 test suite, with its effectiveness compared against nine established optimization methods. The results demonstrate that ARINFO achieved 1st rank overall on both the CEC-2017 and CEC-2022 test suites. When applied to the modified IEEE 30-bus system, ARINFO achieved a minimum generation cost of 781.1538 $/h, reduced emissions to 0.0922140 t/h, and minimized power losses to 1.734974 MW. For the larger IEEE 57-bus system, it attained a total cost of 20193.270 $/h, confirming its scalability and superior performance in managing the OPF problem under uncertainty in both generation and demand scenarios.


17 August 2026 in Electrica
Verified
Journal Article
Open access
PDF file
GMGhazally I. Y. Mustafa
Ghazally I. Y. Mustafa
AAAhmed H. A. Adam
Ahmed H. A. Adam
ABUBAKER AHMED ISMAILABUBAKER AHMED ISMAIL
ABUBAKER AHMED ISMAIL
HWHosham Wahballa
Hosham Wahballa
This paper presents a novel adaptive sliding mode control approach based on a model-free technique for nonlinear active suspension systems in cars. The proposed method comprises four key components: First, an intelligent proportional-integral control based on model-free principles is employed to introduce desired dynamics. Second, an extended state observer is utilized to estimate the system’s nonlinearities and unknown dynamics. Third, an integral sliding surface is integrated to eliminate the reaching phase, along with a noise-sensitive switching mechanism. Last, adaptive gain dynamics are incorporated to improve accuracy. This controller offers several advantages, including its simple structure and ease of adjustment. The study also includes analyses of theoretical system stability, convergence speed, and control accuracy. Finally, the proposed approach is validated using MATLAB simulations and compared with a recent paper on a two-degree-of-freedom nonlinear quarter-car active suspension system.

17 October 2026 in Unconventional Resources
Verified
Journal Article
Open access
AAAhmed H. A. Adam
Ahmed H. A. Adam
MHMohamed H. Hassan
Mohamed H. Hassan
SKSalah Kamel
Salah Kamel