Jakub Żywiec

Dr. Jakub Żywiec

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2024 in Water
Verified
Journal Article
Open access
PDF file
JŻJakub Żywiec
Jakub Żywiec
DSDawid Szpak
Dawid Szpak
KWKatarzyna Wartalska
Katarzyna Wartalska
MGMartyna Grzegorzek
Martyna Grzegorzek
With ongoing climate change, new threats appear to the operation of water supply systems (WSSs), which are related to the amount of available drinking water resources, its quality, the operation of existing water supply infrastructure and changes in consumer behavior. The paper presents a bibliometric analysis of the state of knowledge on the impact of climate change on the failure of water supply infrastructure. The bibliometric analysis was performed based on the VOSviewer program. The results of the analysis indicate current research trends in this area around the world and allow the identification of strengths and weaknesses. Most research concerns the identification of factors related to the impact of climate on the failure rate of water distribution systems. A popular research topic was also the prediction of water supply network failures, taking into account the impact of climatic factors. The main research gap is determining the impact of climate change on water quality. The acquired knowledge can be used by water companies, policy-makers and other researchers to plan adaptation strategies to climate change, which pose new challenges for the operation of water supply systems. The conducted bibliometric analysis also allowed for identifying research gaps.

5 May 2021 in Resources
Verified
Journal Article
Open access
PDF file
KBKrzysztof Boryczko
Krzysztof Boryczko
IPIzabela Piegdoń
Izabela Piegdoń
DSDawid Szpak
Dawid Szpak
JŻJakub Żywiec
Jakub Żywiec
Modern management of water supply systems is based on a preventive strategy consisting of the prevention of failures and crisis situations. Water pipe failures resulting in a lack of water supply for a long period pose a threat to the water consumers safety. The aim of the work was to present the methodology and develop a risk map of lack of water supply to consumers. The article presents a failures simulation of the main pipes transporting treated water from the water treatment plant to the city carried out using the EPANET 2.0. software. The simulation results made it possible to determine the consequences of failures by determining the number of inhabitants (consumers) affected with lack of water supply as a result of failure of the main pipes near the water treatment plant WTP which, together with the failure rate, were used to prepare risk maps of lack of water supply. The developed method was presented on the water supply network located in Central and Eastern Europe. It was found that the highest risk of lack of water supply is related to the failure of the M3 main pipe, which transports water to the eastern and north-eastern parts of the city. It is recommended to modernize the M3 main pipe, which will reduce the number of failures resulting in a lack of water supply.

17 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
KBKrzysztof Boryczko
Krzysztof Boryczko
DSDawid Szpak
Dawid Szpak
JŻJakub Żywiec
Jakub Żywiec
Barbara Tchórzewska-CieślakBarbara Tchórzewska-Cieślak
Barbara Tchórzewska-Cieślak
Background: Specialist literature indicates a large share of the human factor among the causes of failure of technical systems at the level of 70 to 90%, which depends on the sector studied. The collective water supply system is an anthropotechnical system, i.e., it is a complex connection between man and the technical system resulting from the deliberate influence of man on the technical system. Methods: The work presents an assessment of operator reliability of a selected water treatment process based on the fault tree analysis (FTA). Elementary events are determined by the operator’s error probability. Results: A failure tree was prepared for the peak event of the filter station failure, resulting from an operator’s error during the filter washing procedure. The probability of a peak event occurring is 0.0580. Conclusions: The developed fault tree allows for the identification of elementary events leading to an emergency event. The operator fulfills its task of maintaining the continuity of water treatment.

4 December 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
JŻJakub Żywiec
Jakub Żywiec
IPIzabela Piegdoń
Izabela Piegdoń
Barbara Tchórzewska-CieślakBarbara Tchórzewska-Cieślak
Barbara Tchórzewska-Cieślak
The consequences of climate changes are felt by society every day. A sudden increase or decrease in air temperature, increasingly frequent, extreme weather phenomena can cause enormous economic damage to countries and cities. The occurrence of random weather phenomena and their negative impact on technical infrastructure nowadays are the basic problem related to ensuring the safety of the functioning of each system. Climate changes and significant air temperature amplitudes have a direct impact on the functioning of the critical infrastructure of cities, which includes collective water supply systems (CWSS). The paper presents the impact of climate change on the failure of a water supply network. Correlation between failure rate and air temperature was determined. This was used to determine the number of failures for the near 2036–2050 and distant 2086–2100 future in terms of climate change (temperature increase). The results confirm the thesis known from the literature that the failure rate decreases as the temperature increases. For forecasted periods as a result of temperature rise due to climate change, the reduction of the number of water pipe failures is expected in the range of 1.22% to 2.35% for the 2036–2050 period and from 2.96% to 8.66% for the 2086–2100 period, depending on the development of Representative CO2 Concentration Scenarios (RCP). The decrease in the total number of failures will have an impact on the increase in the reliability and safety of water supply to consumers.

27 April 2024 in Journal of Environmental Management
Verified
Journal Article
Closed access
Barbara Tchórzewska-CieślakBarbara Tchórzewska-Cieślak
Barbara Tchórzewska-Cieślak
DSDawid Szpak
Dawid Szpak
JŻJakub Żywiec
Jakub Żywiec
MRMateusz Rożnowski
Mateusz Rożnowski

12 September 2019 in Water
Verified
Journal Article
Open access
PDF file
Dorota PapciakDorota Papciak
Dorota Papciak
Barbara Tchórzewska-CieślakBarbara Tchórzewska-Cieślak
Barbara Tchórzewska-Cieślak
Andżelika DomońAndżelika Domoń
Andżelika Domoń
AWAnna Wojtuś
Anna Wojtuś
JŻJakub Żywiec
Jakub Żywiec
JKJanusz Konkol
Janusz Konkol
The article presents changes in the quality of tap water depending on time spent in installation and its impact on the creation of biofilms on various materials (polyethylene (PE), polyvinyl chloride (PVC), chrome-nickel steel and galvanized steel). For the first time, quantitative analyses of biofilm were performed using methods such as: Adenosine 5’-triphosphate (ATP) measurement, flow cytometry, heterotrophic plate count and using fractographical parameters. In the water, after leaving the experimental installation, the increase of turbidity, content of organic compounds, nitrites and nitrates was found, as well as the decrease in the content of chlorine compounds, dissolved oxygen and phosphorus compounds. There was an increase in the number of mesophilic and psychrophilic bacteria. In addition, the presence of Escherichia coli was also found. The analysis of the quantitative determination of microorganisms in a biofilm indicates that galvanized steel is the most susceptible material for the adhesion of microorganisms. These results were also confirmed by the analysis of the biofilm morphology. The roughness profile, the thickness of the biofilm layer can be estimated at about 300 μm on galvanized steel.