Dorota Papciak

Prof. Dorota Papciak

Faculty of Civil Environmental Engineering and Architecture, Rzeszow University of Technology, Rzeszów, Poland
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2020 in Resources
Verified
Journal Article
Open access
PDF file
MZMonika Zdeb
Monika Zdeb
JZJustyna Zamorska
Justyna Zamorska
Dorota PapciakDorota Papciak
Dorota Papciak
Daniel SłyśDaniel Słyś
Daniel Słyś
The large temporal and spatial variability of rainwater quality, as well as the relatively small number of tests, makes the preliminary assessment of its economic exploitation difficult. Determining the relationship between the conditions and location of rainwater collection and rainwater quality would help indicate the range of options for rainwater use, as well as the parameters that require improvement. The aim of the presented article is to establish the physical, chemical, and microbiological parameters of different rainwater sources and, from the results obtained, determine the possibilities for its safe use in households. The research was carried out for two years. Samples of rainfall were collected from spring to fall from the following roofing materials: Concrete roof tiles, ceramic roof tiles, galvanized steel sheet, and epoxy-coated terrace. The physical, chemical, and microbiological quality were assessed on the basis of the pH, turbidity, electrical conductivity, the concentration of biogenic compounds, the concentration of chosen elements, the number of Escherichia coli, and the number of fecal streptococci. Significant bacterial contamination, decreased pH, and increased turbidity were identified in the water, depending on the parameters of the roofing washed by the rainfall and the intensity and frequency of precipitation.

13 May 2020 in Materials
Verified
Journal Article
Open access
PDF file
Magdalena Maria MichelMagdalena Maria Michel
Magdalena Maria Michel
LRLidia Reczek
Lidia Reczek
Dorota PapciakDorota Papciak
Dorota Papciak
Maria Wlodarczyk-MakulaMaria Wlodarczyk-Makula
Maria Wlodarczyk-Makula
Tadeusz SiwiecTadeusz Siwiec
Tadeusz Siwiec
Yuliia TrachYuliia Trach
Yuliia Trach
For groundwater treatment, the technologies involving oxidation on MnOx filter bed are beneficial, common, and effectively used. The presence of MnOx is the mutual feature of filter media, both MnOx-coated mineral materials like quartz sand and gravel, chalcedonite, diatomite, glauconite, zeolite, or anthracite along with consisting of MnOx manganese ores. This review is based on the analysis of research and review papers, commercial data sheets, and standards. The paper aimed to provide new suggestions and useful information for further investigation of MnOx filter media for groundwater treatment. The presented compilations are based on the characteristics of coatings, methods, and conditions of its obtaining and type of filter media. The relationship between the properties of MnOx amendments and the obtained purification effects as well as the commonly used commercial products, their features, and applications have been discussed. The paper concludes by mentioning about improving catalytic/adsorption properties of non-reactive siliceous media opposed to ion-exchange minerals and about possible significance of birnessite type manganese oxide for water treatment. Research needs related to the assessment of the use MnOx filter media to heavy metals removal from groundwater in field operations and to standardize methodology of testing MnOx filter media for water treatment were identified.

26 July 2017 in Archives of Environmental Protection
Verified
Journal Article
Open access
PDF file
JKJadwiga Kaleta
Jadwiga Kaleta
MKMałgorzata Kida
Małgorzata Kida
PKPiotr Koszelnik
Piotr Koszelnik
Dorota PapciakDorota Papciak
Dorota Papciak
APAlicja Puszkarewicz
Alicja Puszkarewicz
BTBarbara Tchórzewska-Cieślak
Barbara Tchórzewska-Cieślak
The article presents research results of the introduction of powdery activated carbon to the existing technological system of the groundwater treatment stations in a laboratory, pilot plant and technical scale. The aim of the research was to reduce the content of organic compounds found in the treated water, which create toxic organic chlorine compounds (THM) after disinfection with chlorine. Nine types of powdery active carbons were tested in laboratory scale. The top two were selected for further study. Pilot plant scale research was carried out for the filter model using CWZ-30 and Norit Sa Super carbon. Reduction of the organic matter in relation to the existing content in the treated water reached about 30%. Research in technical scale using CWZ-30 carbon showed a lesser efficiency with respect to laboratory and pilot-plant scale studies. The organic matter decreased by 15%. Since filtration is the last process before the individual disinfection, an alternative solution is proposed, i.e. the second stage of filtration with a granular activated carbon bed, operating in combined sorption and biodegradation processes. The results of tests carried out in pilot scale were fully satisfactory with the effectiveness of 70–100%.

11 October 2021 in Resources
Verified
Journal Article
Open access
PDF file
MZMonika Zdeb
Monika Zdeb
JZJustyna Zamorska
Justyna Zamorska
Dorota PapciakDorota Papciak
Dorota Papciak
ASAgata Skwarczynska
Agata Skwarczynska
Rainwater has been found to be a valuable source of drinking water in Europe, especially in such crisis situations as those caused by contamination of water uptake into water supply systems, large-scale floods or terrorist attacks (e.g., biological weapons). The microbiological quality of water plays a significant role, which is directly related to the potential health risks associated with harvested rainwater (including rainwater stored in the tanks). Microbial contamination is commonly found in rainwater. However, in the literature, detailed results of qualitative and quantitative microbiological assessments are sparse and remain unexplored. Therefore, the aim of this study was to investigate and analyze changes in the microbiological quality of roof-harvested rainwater stored in the tanks, depending on the collection conditions (type of roof surface), storage duration and season. Authors elucidate that conditions such as storage duration, the season in which rainwater is collected, the roof-like surface types and morphology of the catchment area highly affect rainwater quality. This study showed that rainwater harvested from a galvanized steel sheet roof had the best microbial quality, regarding the lowest number of bacteria, while rainwater from a flat roof covered with epoxy resin was the worst. Further, it was detected that rainwater collected in autumn and spring obtained the best microbiological quality. Moreover, a decrease in the number of bacteria was observed in correlation to storage duration. The water became sanitary safe after six weeks of storage at 12 °C. Its use for purposes requiring drinking water quality before six weeks of storage required disinfection.

12 September 2019 in Water
Verified
Journal Article
Open access
PDF file
Dorota PapciakDorota Papciak
Dorota Papciak
Barbara Tchórzewska-CieślakBarbara Tchórzewska-Cieślak
Barbara Tchórzewska-Cieślak
Andżelika DomońAndżelika Domoń
Andżelika Domoń
AWAnna Wojtuś
Anna Wojtuś
JŻJakub Żywiec
Jakub Żywiec
JKJanusz Konkol
Janusz Konkol
The article presents changes in the quality of tap water depending on time spent in installation and its impact on the creation of biofilms on various materials (polyethylene (PE), polyvinyl chloride (PVC), chrome-nickel steel and galvanized steel). For the first time, quantitative analyses of biofilm were performed using methods such as: Adenosine 5’-triphosphate (ATP) measurement, flow cytometry, heterotrophic plate count and using fractographical parameters. In the water, after leaving the experimental installation, the increase of turbidity, content of organic compounds, nitrites and nitrates was found, as well as the decrease in the content of chlorine compounds, dissolved oxygen and phosphorus compounds. There was an increase in the number of mesophilic and psychrophilic bacteria. In addition, the presence of Escherichia coli was also found. The analysis of the quantitative determination of microorganisms in a biofilm indicates that galvanized steel is the most susceptible material for the adhesion of microorganisms. These results were also confirmed by the analysis of the biofilm morphology. The roughness profile, the thickness of the biofilm layer can be estimated at about 300 μm on galvanized steel.

1 December 2017 in Archives of Environmental Protection
Verified
Journal Article
Open access
PDF file
Katarzyna Pietrucha UrbanikKatarzyna Pietrucha Urbanik
Katarzyna Pietrucha Urbanik
Barbara Tchórzewska-CieślakBarbara Tchórzewska-Cieślak
Barbara Tchórzewska-Cieślak
Dorota PapciakDorota Papciak
Dorota Papciak
ISIzabela Skrzypczak
Izabela Skrzypczak
The main goal of this work is to show the new approach to determining safety technological levels (SLs) in terms of water quality and its chemical stability, as well as issues of water corrosion properties in water distribution systems (WDSs), due to the fact that water supply pipes are prone to corrosion. In the paper the methodology of determining the risk associated with threat to technical infrastructure was considered. The concept was studied on the basis of real operational data from the water treatment plant. The probability of exceeding the individual parameters for WTPI is slightly larger than for WTPII, which means that this water treatment process may cause lack of chemical stability in the water supply network. Operators should anticipate in the process of designing water distribution system, using proper materials, as to ensure an adequate level of safety from the water source to the water recipient. It should be noted that it is necessary to adjust the material of internal installation of water supply networks to the parameters of the water. At present, there are no correlations between the designing step and water parameters. It was concluded that to protect the water supply infrastructure, which belongs to critical infrastructure, water company should put more emphasis on distribution of stable water that has not potentially corrosion properties. Some suggestions were made for the protection of WDS and to ensure safety of system functioning and long-term usability of water pipes.