Herman Otto Mayr

Prof. Herman Otto Mayr

Artemed Hospital Munich South, Munich, Bavaria, Germany
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2015 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
KTKathi Thiele
Kathi Thiele
CPCarsten Perka
Carsten Perka
GMGeorg Matziolis
Georg Matziolis
HMHerman Otto Mayr
Herman Otto Mayr
MSMichael Sostheim
Michael Sostheim
RHRobert Hube
Robert Hube
Acements during 2005 to 2010 at two high-volume arthroplasty centers. A revision was defined as the replacement of at least one prosthetic component. In the descriptive analysis, polyethylene wear, aseptic loosening, periprosthetic infection, malalignment, instability, arthrofibrosis, extensor mechanism deficiency, periprosthetic fracture, and retropatellar arthritis were given as the failure mechanism associated with an early, intermediate, or late time interval (less than one year, one to three years, and more than three years, respectively) after the index total knee arthroplasty. Results: Three hundred and fifty-eight revision total knee arthroplasties were included. Of those revisions, 19.8% were performed within the first year after the index arthroplasty. The most common indications for revision, besides aseptic loosening (21.8%), were instability (21.8%), malalignment (20.7%), and periprosthetic infection (14.5%). Revisions due to polyethylene wear (7%) rarely occurred. In the early failure group, the primary causes of revision were periprosthetic infection (26.8%) and instability (23.9%). In the intermediate group, instability (23.3%) and malalignment (29.4%) required revision surgery, whereas late failure mechanisms were aseptic loosening (34.7%), instability (18.5%), and polyethylene wear (18.5%). Conclusions: Aseptic loosening, instability, malalignment, and periprosthetic infection continue to be the primary failure mechanisms leading to revision surgery. Contrary to previous literature, the results in the present study showed a substantial reduction in implant-associated revisions such as those due to polyethylene wear. Failure mechanisms that occur persistently early and in the intermediate term, such as periprosthetic infection, instability, and malalignment, remain common causes of revision surgery. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence....

3 August 2004 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
HMHerman Otto Mayr
Herman Otto Mayr
TWThomas G. Weig
Thomas G. Weig
WPWolfgang Plitz
Wolfgang Plitz

22 December 2017 in Materials
Verified
Journal Article
Open access
PDF file
Michael SeidenstueckerMichael Seidenstuecker
Michael Seidenstuecker
LKLaura Kerr
Laura Kerr
ABAnke Bernstein
Anke Bernstein
HMHerman Otto Mayr
Herman Otto Mayr
NSNorbert P. Suedkamp
Norbert P. Suedkamp
SESteffen Esslinger
Steffen Esslinger
The use of both bioglass (BG) and β tricalcium phosphate (β-TCP) for bone replacement applications has been studied extensively due to the materials’ high biocompatibility and ability to resorb when implanted in the body. 3D printing has been explored as a fast and versatile technique for the fabrication of porous bone scaffolds. This project investigates the effects of using different combinations of a composite BG and β-TCP powder for 3D printing of porous bone scaffolds. Porous 3D powder printed bone scaffolds of BG, β-TCP, 50/50 BG/β-TCP and 70/30 BG/β-TCP compositions were subject to a variety of characterization and biocompatibility tests. The porosity characteristics, surface roughness, mechanical strength, viability for cell proliferation, material cytotoxicity and in vitro bioactivity were assessed. The results show that the scaffolds can support osteoblast-like MG-63 cells growth both on the surface of and within the scaffold material and do not show alarming cytotoxicity; the porosity and surface characteristics of the scaffolds are appropriate. Of the two tested composite materials, the 70/30 BG/β-TCP scaffold proved to be superior in terms of biocompatibility and mechanical strength. The mechanical strength of the scaffolds makes them unsuitable for load bearing applications. However, they can be useful for other applications such as bone fillers.

17 February 2012 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
HMHerman Otto Mayr
Herman Otto Mayr
DWDoerthe Willkomm
Doerthe Willkomm
ASAmelie Stoehr
Amelie Stoehr
MSMathias Schettle
Mathias Schettle
NSNorbert P. Suedkamp
Norbert P. Suedkamp
RHRobert Hube
Robert Hube

1 January 2015 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
PDF file
MZMartin Zens
Martin Zens
MFMatthias J Feucht
Matthias J Feucht
JRJohannes Ruhhammer
Johannes Ruhhammer
ABAnke Bernstein
Anke Bernstein
HMHerman Otto Mayr
Herman Otto Mayr
PNPhilipp Niemeyer
Philipp Niemeyer
Background: In a noticeable percentage of patients anterolateral rotational instabilities (ALRI) remain after an isolated ACL reconstruction. Those instabilities may occur due to an insufficiently directed damage of anterolateral structures that is often associated with ACL ruptures. Recent publications describe an anatomical structure, termed the anterolateral ligament (ALL), and suggest that this ligament plays a significant role in the pathogenesis of ALRI of the knee joint. However, only limited knowledge about the biomechanical characteristics and tensile properties of the anterolateral ligament exists.Methods: The anterolateral ligament was dissected in four fresh‐frozen human cadaveric specimens and all surrounding tissue removed. The initial length of the anterolateral ligament was measured using a digital caliper. Tensile tests with load to failure were performed using a materials testing machine. The explanted anterolateral ligaments were histologically examined to measure the cross‐sectional area.Results: The mean ultimate load to failure of the anterolateral ligament was 49.90 N (± 14.62 N) and the mean ultimate strain was 35.96% (± 4.47%). The mean length of the ligament was 33.08 mm (± 2.24) and the mean cross‐sectional area was 1.54 mm2 (± 0.48 mm2). Including the areal measurements the maximum tension was calculated to be 32.78 (± 4.04 ).Conclusions: The anterolateral ligament is an anatomical structure with tensile properties that are considerably weaker compared to other peripheral structures of the knee. Knowledge of the anterolateral ligament’s tensile strengths may help to better understand its function and with graft choices for reconstruction procedures.

23 May 2006 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
HMHerman Otto Mayr
Herman Otto Mayr
EEElmar Entholzner
Elmar Entholzner
RHRobert Hube
Robert Hube
WHWerner Hein
Werner Hein
TWThomas G. Weig
Thomas G. Weig