Microgrids are a highly efficient means of embedding distributed generation sources in a power system. However, if a fault occurs inside or outside the microgrid, the microgrid should be immediately disconnected from the main grid using a static switch installed at the secondary side of the main transformer near the point of common coupling (PCC). The static switch should have a reliable module implemented in a chip to detect/locate the fault and activate the breaker to open the circuit immediately. This paper proposes a novel approach to design this module in a static switch using the discrete wavelet transform (DWT) and adaptive network-based fuzzy inference system (ANFIS). The wavelet coefficient of the fault voltage and the inference results of ANFIS with the wavelet energy of the fault current at the secondary side of the main transformer determine the control action (open or close) of a static switch. The ANFIS identifies the faulty zones inside or outside the microgrid. The proposed method is applied to the first outdoor microgrid test bed in Taiwan, with a generation capacity of 360.5 kW. This microgrid test bed is studied using the real-time simulator eMegaSim developed by Opal-RT Technology Inc. (Montreal, QC, Canada). The proposed method based on DWT and ANFIS is implemented in a field programmable gate array (FPGA) by using the Xilinx System Generator. Simulation results reveal that the proposed method is efficient and applicable in the real-time control environment of a power system.
This paper explores real power generation planning, considering distributed generation resources and energy storage in a small standalone power system. On account of the Kyoto Protocol and Copenhagen Accord, wind and photovoltaic (PV) powers are considered as clean and renewable energies. In this study, a genetic algorithm (GA) was used to determine the optimal capacities of wind-turbine-generators, PV, diesel generators and energy storage in a small standalone power system. The investment costs (installation, unit and maintenance costs) of the distributed generation resources and energy storage and the cost of fuel for the diesel generators were minimized while the reliability requirement and CO2 emission limit were fulfilled. The renewable sources and loads were modeled by random variables because of their uncertainties. The equality and inequality constraints in the genetic algorithms were treated by cumulant effects and cumulative probability of random variables, respectively. The IEEE reliability data for an 8760 h load profile with a 150 kW peak load were used to demonstrate the applicability of the proposed method.
The expression and calculation of transmission loss (TL) play key roles for solving the power system economic dispatch (ED) problem. ED including TL must compute the total TL and incremental transmission loss (ITL) by executing power flow equations. However, solving the power flow equations is time-consuming and may result in divergence by the iteration procedure. This approach is unsuitable for real-time ED in practical power systems. To avoid solving nonlinear power flow equations, most power companies continue to adopt the TL formula in ED. Traditional loss formulas are composed of network parameters and in terms of the generator’s real power outputs. These formulas are derived by several assumptions, but these basic assumptions sacrifice accuracy. In this study, a new expression for the loss formula is proposed to improve the shortcomings of traditional loss formulas. The coefficients in the new loss formula can be obtained by recording the power losses according to varying real and reactive power outputs without any assumptions. The simultaneous equations of the second-order expansion of the Taylor series are then established. Finally, the corresponding coefficients can be calculated by solving the simultaneous equations. These new coefficients can be used in optimal real and reactive power dispatch problems. The proposed approach is tested by IEEE 14-bus and 30-bus systems, and the results are compared with those obtained from the traditional B coefficient method and the load flow method. The numerical results show that the proposed new loss formula for ED can hold high accuracy for different loading conditions and is very suitable for real-time applications.
This study aimed to minimize energy losses in traditional distribution networks and microgrids through a network reconfiguration and phase balancing approach. To address this problem, an algorithm composed of a multi-objective function and operation constraints is proposed. Network connection matrices based on graph theory and the backward/forward sweep method are used to analyze power flow. A minimizing energy loss approach is developed for network reconfiguration and phase balancing, and the particle swarm optimization (PSO) algorithm is adopted to solve this optimal combination problem. The proposed approach is tested on the IEEE 37-bus test system and the first outdoor microgrid test bed established by the Institute of Nuclear Energy Research (INER) in Taiwan. Simulation results demonstrate that the proposed two-stage approach can be applied in network reconfiguration to minimize energy loss.
Data acquisition and supervisory control are usually performed using client-server architecture and centralized control in conventional power systems. However, the message transmission and fault clearing are too slow for large-scale complex power systems. Microgrid systems have various types of distributed energy resources (DERs) which are quite different in characteristics and capacities, thus, the client-server architecture and centralized control are inadequate to control and operate in microgrids. Based on MATLAB/Simulink (ver.R2012a) simulation software and Java Agent Development Framework (JADE) (JADE 4.1.1-revision 6532), this paper proposes a novel fault protection technology that used multi-agent system (MAS) to perform fault detection, fault isolation and service restoration in microgrids. A new topology identification method using the YBus Matrix Algorithm is presented to successfully recognize the network configurations. The identification technology can respond to microgrid variations. Furthermore, the interactive communications among intelligent electronic devices (IEDs), circuit breakers (CBs), and agents are clarified during fault occurrence. The simulation results show that the proposed MAS-based microgrids can promptly isolate faults and protect the system against faults in real time.
To perform the fault protection for the microgrid in grid-connected mode, the wavelet energy fuzzy neural network-based technique (WEFNNBT) is proposed in this paper. Through the accurate activation of protective relay, the microgrid can be effectively isolated from the utility power system to prevent serious voltage fluctuation when the power quality of power system is disturbed. The proposed WEFNNBT can be divided into three stages—feature extraction (FE), feature condensation (FC), and disturbance identification (DI). In the FE stage, the feature of power signal at the point of common coupling (PCC) between microgrid and utility power system would be extracted with discrete wavelet transform (DWT). Then, the wavelet energy and variation of singular power signal can be obtained according to Parseval Theorem. To determine the dominant wavelet energy and enhance the robustness to the noise, the feature information is integrated in the FC stage. The feature information then would be processed in the DI stage to perform the fault identification and activate the protective relay if necessary. From the experimental results, it is realized that the proposed WEFNNBT can effectively perform the fault protection of microgrid.