Objective: Ex-vivo lung perfusion is a promising tool to evaluate and recondition marginal donor lungs usually after a cold static preservation. The concept of continuous organ perfusion is supposed to reduce ischemic damage; however, the optimal perfusion protocol has not been established yet. The aim of this study was to compare immediate ex-vivo lung perfusion (I-EVLP) to delayed ex-vivo lung perfusion (D-EVLP) after a certain cold static preservation period on lung function in a large animal model. Methods: In a porcine model, lungs were procured after circulatory death and 60 min of no-touch warm ischemia. Lungs were preserved with single-flush cold low potassium dextran solution and prepared either for I-EVLP (n = 8) or stored cold for 9 h with subsequent D-EVLP (n = 8). Functional outcomes and morphology were compared during 4 h of ex-vivo lung perfusion, using STEEN SolutionTM as perfusion solution. Results: Pulmonary functional data, perfusate activities of lactate dehydrogenase, alkaline phosphatase, and products of lipid peroxidation did not differ significantly. There was a trend toward lower wet–dry ratio (I-EVLP: 13.4 ± 2.9; D-EVLP: 9.1 ± 2.5) and higher ΔpO2 in D-EVLP group (I-EVLP: 209 ± 51.6 mmHg; D-EVLP: 236.3 ± 47.3 mmHg). Conclusion: In this donation-after-circulatory-death model, 9 h of cold static preservation followed by ex-vivo lung perfusion results in comparable pulmonary function to I-EVLP as indicated by oxygenation capacities and wet–dry ratio. Our findings indicate that prolonged cold static preservation prior to ex-vivo lung perfusion is as safe and effective as I-EVLP in the procurement of donor lungs.
5 July 2018 in The International Journal of Artificial Organs
Objective: To enlarge the donor pool for lung transplantation, an increasing number of extended criteria donor lungs are used. However, in more than 50% of multi-organ donors the lungs are not used. Ex vivo lung perfusion offers a unique possibility to evaluate and eventually recondition the injured donor lungs. The aim of our study was to assess the enlargement of the donor pool and the outcome with extended criteria donor lungs after ex vivo lung perfusion. Patients and Methods: Data were prospectively collected in our lung transplant database. We compared the results of lung transplants after ex vivo lung perfusion with those after conventional cold static preservation. In total, 11 extended criteria donor lungs processed with ex vivo lung perfusion and 41 cold static preservation lungs transplanted consecutively between May 2016 and May 2017 were evaluated. Normothermic ex vivo lung perfusion was performed according to the Toronto protocol for 4 h. Cold static preservation lungs were stored in low-potassium dextran solution. Results: Ex vivo lung perfusion lungs before procurement had significantly lower PaO2/FiO2 (P/F) ratios and more X-ray abnormalities. There were no statistically significant differences for pre-donation ventilation time, smoking history, or sex. After reconditioning with ex vivo lung perfusion, 9 out of 11 processed lungs were considered suitable and successfully transplanted. The mean postoperative ventilation time and in-hospital stay were not significantly different in ex vivo lung perfusion and cold static preservation recipients. Conclusion: Ex vivo lung perfusion can safely be used in the evaluation of lungs initially considered not suitable for transplantation. The primary outcome was not negatively affected and normothermic ex vivo lung perfusion is a useful tool to increase the usage of potentially transplantable lungs.
4 September 2023 in The Journal of Heart and Lung Transplantation
Ex vivo lung perfusion (EVLP) has expanded the donor pool for lung transplantation. Pulmonary Staphylococcus aureus infection, especially that caused by multidrug-resistant strains, is a severe threat to posttransplantation outcomes. Sphingosine is a lipid compound that exhibits broad-spectrum antibacterial activity. Therefore, we aimed to evaluate the effects of S aureus infection on EVLP and whether sphingosine administration during EVLP prevents infection with S aureus. Eighteen pigs were randomly assigned to 3 groups: uninfected, infected with S aureus with NaCl treatment, or infected with sphingosine treatment. Bacterial numbers were determined before and after treatment. Sphingosine concentrations in the lung tissues were determined using biochemical assays. Lung histology, lung physiological parameters, perfusate content, lung weight, and cell death were measured to analyze the effects of infection and sphingosine administration on EVLP. Sphingosine administration significantly reduced the bacterial load. The concentration of sphingosine in the bronchial epithelium was elevated after sphingosine administration. S aureus infection increased pulmonary artery pressure and pulmonary vascular resistance. Lung edema, histology scores, lactate and lactate dehydrogenase levels in the perfusate, ΔPO2 in the perfusate, static lung compliance, and lung peak airway pressure did not differ among the groups. Infection of S aureus did not affect the lung function during EVLP but induced higher pulmonary artery pressure and pulmonary vascular resistance. Administration of sphingosine effectively eliminated S aureus without side effects in isolated, perfused, and ventilated pig lungs.
Background and Objectives: The understanding of high body mass index (BMI) and outcomes after Left Ventricular Assist Device (LVAD) implantation continues to evolve and the relationship has not been established yet. In this study, we investigated the effects of obesity (BMI > 30 kg/m2) on post–LVAD implantation outcomes. HeartWare LVAD and Heart Mate III LVAD were implanted. The primary outcome that was measured was mortality (in-hospital and on follow-up). The secondary outcomes that were measured were major adverse events. Materials and Methods: At our institution, the West German Heart and Vascular Center (Essen, Germany), from August 2010 to January 2020, a total of 210 patients received a long-term LVAD. Patients were stratified according to BMI ≥ 30 kg/m2 representing the obesity threshold. The first group (n = 162) had an average BMI of 24.2 kg/m2 (±2.9), and the second group (n = 48) had an average BMI of 33.9 kg/m2 (±3.2). Baseline demographics were analysed alongside comorbidities per group. Results: Overall mortality was not significantly different between the obese group (51.1% n = 24) and the nonobese group (55.2%, n = 85) (p = 0.619). The difference between the mean duration of survival of patients who expired after hospital discharge was insignificant (2.1 years ± 1.6, group 1; 2.6 years ± 1.5, group 2; p = 0.29). In-hospital mortality was unvaried between the two groups: group 1: n = 34 (44% out of overall group 1 deaths); group 2: n = 11 (45.8% out of overall group 2 deaths) (p > 0.05). Postoperative complications were unvaried between the obese and the non-obese group (all with p > 0.05). However, a significant difference was found with regards to follow-up neurological complications (18.5% vs. 37.8%, p = 0.01) and LVAD thrombosis (14.7% vs. 33.3%, p = 0.01), as both were higher in the obese population. Conclusion: Obesity does not form a barrier for LVAD implantation in terms of mortality (in-hospital and on follow up). However, a significantly higher incidence of follow-up LVAD thrombosis and neurological complications has been found in the obese group of patients.
15 November 2017 in European Journal of Medical Research
Resternotomy in cardiac surgery is considered a risk factor for postoperative complications. Previous studies have demonstrated an ambiguous relationship between resternotomy and clinical outcomes. Registry data from a mixed population of durable circulatory support devices suggest that history of cardiac surgery is a risk factor for mortality. Our study investigates the prognostic significance of resternotomy in a homogenous cohort of left ventricular assist device (LVAD) recipients. The study included adult patients receiving a continuous-flow LVAD at our institution during the period 2010–2016. Postoperative adverse events and length of stay were analyzed. Survival was assessed at 6 months and by the end of the study. Multivariate risk factor analysis was conducted for independent predictors of death. One hundred twelve patients, who received an intrapericardial LVAD (HVAD, HeartWare), were included in our analysis. Twenty-four patients (21.4%) had a history of previous sternotomy. These patients were older and non-eligible for bridging, and had more frequently coronary heart disease. Univariate analysis demonstrated no differences in the observed complications postoperatively. Survival was similar among groups. Destination therapy was the only predictor of mortality in our analysis (p = 0.02). Resternotomy was not associated with worse outcomes after LVAD implantation in our cohort.
2 February 2021 in The International Journal of Artificial Organs
Introduction: Ex vivo lung perfusion (EVLP) is an established technique to evaluate and eventually recondition lungs prior to transplantation. Custodiol-MP (C-MP) solution is a new solution, designed for clinical machine perfusion, that has been used for kidneys. The aim of this study was to compare the effects of EVLP with Custodiol-MP on lung functional outcomes to the gold standard of EVLP with Steen Solution™. Material and Methods: In a porcine EVLP model of DCDD (Donation after Circulatory Determination of Death), lungs were perfused with Steen Solution™ (SS, n = 7) or Custodiol-MP solution supplemented with 55 g/l albumin (C-MP, n = 8). Lungs were stored cold for 4 h in low potassium dextran solution and subsequently perfused ex vivo for 4 h. During EVLP pulmonary gas exchange, activities of lactate dehydrogenase (LDH) and alkaline phosphatase (AP) as well as levels of lactate in the perfusate were recorded hourly. Results: Oxygenation capacity differed significantly between groups (averaged over 4 h: SS 274 ± 178 mmHg; C-MP 284 ± 151 mmHg p = 0.025). Lactate dehydrogenase activities and lactate concentrations were significantly lower in Custodiol-MP perfused lungs. In a porcine model of DCDD with 4 h of EVLP the use of modified Custodiol-MP as perfusion solution was feasible. The use of C-MP showed at least comparable lung functional outcomes to the use of Steen Solution TM . Furthermore C-MP perfusion resulted in significantly lower lactate dehydrogenase activity and lactate levels in the perfusate and higher oxygenation capacity.